MODEL(s): LE,SUPER
SUPER CLASSIC LE
100323-28 SUPER LE / SUPER CLASSIC LE 10 000113 3
OPERATING AND
INSTALLATION
INSTRUCTIONS
SAFETY NOTICE
If this stove is not properly installed, a
house re may result. For your safety,
follow the installation instructions.
Contact local building or re ofcials
about restrictions and installation
inspection requirements in your area.
Meets the Environmental Protection
Agency's 2020 Particulate Emission
Standards (Crib Wood).
IMPORTANT:
THESE INSTRUCTIONS ARE TO
REMAIN WITH THE HOMEOWNER
SERIAL #
Visit www.pacificenergy.net for the most recent version of this manual
Experience will give you the right settings for proper combustion and efcient burning. Remember the correct air inlet
setting is affected by variables such as type of wood, outside temperature, chimney size and weather conditions. With
practice, you will become procient in operating your heater and will obtain the performance for which it was designed.
Table of Contents
Contents
Table of Contents 2 ......................................................................
Rating Label 3 ..............................................................................
Efciency and BTU Output 3 .................................................
Safety 4 ........................................................................................
Chimney Smoke and Creosote Formation 4 .........................
Chimney Fires 4 ....................................................................
To Avoid a Chimney Fire..................................................... 5
In Case of a Chimney Fire 5 ..................................................
Curing of the Paint Finish 5 ...................................................
Operation 6 ...................................................................................
Wood Selection 6 ..................................................................
DO NOT BURN : 6 .................................................................
How to Test Your Wood 6 ......................................................
Lighting a re 7 ......................................................................
Normal Operation 7 ...............................................................
Restarting After Extended or Overnight Burns 8 ..................
Proper Draft 8 ........................................................................
Ash Removal 8 ......................................................................
Ash Cleanout system (optional): 8 ......................................
Disposal of Ashes............................................................... 8
Maintenance 9 ..............................................................................
Maintenance Checks 10 ...............................................................
Weekly: 10 .............................................................................
Monthly ................................................................................
10
When Cleaning the Chimney System: 10 ..............................
Blower: 10 .............................................................................
Bafe: 10 ...............................................................................
Bafe Removal 10 ........................................................................
Dimensions 11 ..............................................................................
Crate Removal 12 .........................................................................
Assembly - Legs (Leg Model) 12 ..................................................
Assembly - Optional Ash Cleanout 12 .........................................
Pedestal Model 12 ................................................................
Leg Model 12 ........................................................................
Ash Dump Installation 13 ......................................................
Floor Protector 14 ........................................................................
Residential Installation ............................................................. 15
Clearances: 15 ......................................................................
Chimney and Connector 16 ..................................................
When using a Double-Wall Connector 16 .............................
When using a Single-Wall (smoke pipe) Connector 16 .........
Installation Procedure 17 ......................................................
Combustion Air 17 ........................................................................
Through Wall Installations 20 ...............................................
Mobile Home Installation 22 .........................................................
Clearances 22 .......................................................................
Optional Blower 23 .......................................................................
Blower Operation 23 .............................................................
Firebrick Installation 23 ................................................................
Trouble Shooting 25 .....................................................................
Parts Diagram - SUPER LE 26 .....................................................
Parts Diagram - SUPER CLASSIC LE 27 .....................................
HOT GLASS WILL CAUSE
BURNS.
DO NOT UCH GLASS UNTIL TO
COOLED.
NEVER ALLOW CHILDREN TO
TOUCH GLASS.
!
WARNING
PLEASE SAVE THESE INSTRUCTIONS
NOTE: WE STRONGLY RECOMMEND THAT SMOKE AND CARBON MONOXIDE DETECTORS BE INSTALLED IN
THE AREA WHERE THE HEATER IS TO BE INSTALLED.
If smoke detectors have been previously installed, you may notice that they are operating more frequently. This may be
due to curing of stove paint or fumes caused by accidentally leaving the re door open. Do not disconnect the detectors.
SAFETY NOTICE: If this stove is not properly installed, a house fire may result. For your safety, follow the
installation instructions. Contact local building or fire officials about restrictions and installation inspection
requirements in you area.
Please read this entire manual before you install and use your new room heater. Failure to follow instructions may result
in property damage, bodily injury, or even death.
SUPER-LE_100323-28
2
100001133
Rating Label
PLEASE SAVE THESE INSTRUCTIONS
This manual describes the installation and operation of
the Pacic Energy, SUPER LE / SUPER CLASSIC LE
Freestanding wood heater.
SAFETY NOTICE:
This wood heater needs periodic inspection and repair
for proper operation. It is against federal regulations to
operate this wood heater in a manner inconsistent with the
operating instructions in this manual.
EPA Certied Emissions 1.8 grams per hour
LHV Tested Efciency 1 77.1%
HHV Tested Efciency 2 71.3%
EPA BTU Output 3 12,518 to 38,177 btu/hr.
Maximum Wood Length 18 inches
Ideal Wood Length 17 inches
Fuel Seasoned Cord wood
1 Weighted Average Lower Heating Value (LHV) efciency as
tested using CSA B415 Performance testing of solid-fuel-
burning heating appliances. LHV assumes the moisture is
already in a vapour state so there is no loss of energy
2 Weighted Average Higher Heating Value (HHV) efciency
as tested using CSA B415 Performance testing of solid-fuel-
burning heating appliances. HHV includes the energy required
to vaporize the water in the fuel
3 The range of BTU outputs is based on efciency using CSA
B415 Performance testing of solid-fuel-burning heating appli-
ances and burn rates from the low and high EPA tests using
Douglas Fir dimensional lumber.
Efficiency and BTU Output
SAMPLE
This heater meets the 2020 U.S. Environmental Protection
Agency's crib wood emission limits for wood heaters sold
after May 15, 2020 using Method 28R.
Model SUPER LE / SUPER CLASSIC LE: 1.8 g/hr..
Under specic test conditions this heater has been shown
to deliver heat at rates ranging from 12,500 to 38,200Btu/
hr.
CERTIFIED FOR CANADA AND U.S.A. - MODEL / MODÈLE: SUPER LE SUPER CLASSIC LE ALDERLEA T5 LE
LISTED ROOM HEATER, SOLID FUEL TYPE. ALSO FOR USE IN MOBILE HOMES.
CERTIFIED TO/ CERTIFIÉ POUR : CAN/ULC S627-00 / UL 1482-2011
Refer to Intertek’s Directory of Building Products for detailed information
ADJACENT WALL
BACK WALL
D
A
SIDE WALL
BE
ADJACENT WALL
F
C
MUR COTE
MUR ARRIERE
MUR ADJACENT
MUR ADJACENT
A.
14 in. / 356 mm
B.
8 in. / 152 mm
C.
7 in. / 178 mm
SUPER
D.
23 in. / 585 mm
E.
15 in. / 380 mm
F.
18 in. / 460 mm
ALDERLEA T5
D.
23.5 in. / 595 mm
E.
15 in. / 380 mm
F.
21 in. / 535 mm
• INSTALL AND USE IN ACCORDANCE WITH THE MANUFACTURER’S INSTALLATION AND OPERATING
INSTRUCTIONS.
• CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS, INSTALLATION PERMIT AND
INSPECTION IN YOUR AREA.
• DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE (USA. ONLY).
• USE 6 INCH / 150MM DIAMETER MINIMUM 24 MSG BLACK OR LISTED CONNECTOR.
• CAN BE CONNECTED TO A LINED MASONRY CHIMNEY SUITABLE FOR USE WITH SOLID FUELS.
• DO NOT OBSTRUCT THE SPACE BENEATH THE HEATER.
• SEE LOCAL BUILDING CODE AND MANUFACTURER'S INSTRUCTIONS FOR PRECAUTIONS REQUIRED
WHEN PASSING A CHIMNEY THROUGH A COMBUSTIBLE WALL OR CEILING.
• DO NOT PASS A CHIMNEY CONNECTOR THROUGH A COMBUSTIBLE WALL OR CEILING.
• MINIMUM CLEARANCE BETWEEN SINGLE WALL CHIMNEY CONNECTOR AND COMBUSTIBLE
MATERIALS-18INCHES/455MM. CLEARANCE MAY BE REDUCED BY THE USE OF LISTED PIPE
SHIELDS, WALL PROTECTORS OR OTHER MEANS APPROVED BY LOCAL BUILDING OR FIRE
OFFICIALS.
• COMPONENTS REQUIRED FOR MOBILE HOME AND ALCOVE INSTALLATION: OUTSIDE AIR KIT.
BOTH CHIMNEY SYSTEM AND CONNECTOR MUST BE LISTED TO:
IN CANADA - ULC S-641 LISTED CONNECTOR
IN CANADA - ULC S-641 LISTED CONNECTOR
IN CANADA - ULC S-641 LISTED CONNECTOR
IN CANADA - ULC S-641 LISTED CONNECTOR AND ULC-S-629 LISTED CHIMNEY
AND ULC-S-629 LISTED CHIMNEY
AND ULC-S-629 LISTED CHIMNEY
AND ULC-S-629 LISTED CHIMNEY
IN CANADA - ULC S-641 LISTED CONNECTOR AND ULC-S-629 LISTED CHIMNEY
IN USA - UL-103 HT LISTED CONNECTOR
IN USA - UL-103 HT LISTED CONNECTOR
IN USA - UL-103 HT LISTED CONNECTOR
IN USA - UL-103 HT LISTED CONNECTOR AND CHIMNEY
AND CHIMNEY
AND CHIMNEY
AND CHIMNEY
IN USA - UL-103 HT LISTED CONNECTOR AND CHIMNEY
• HORIZONTAL CONNECTOR NOT PERMITTED IN MOBILE HOMES
• USE COMPONENTS SPECIFIED IN VENT MANUFACTURERS INSTALLATION INSTRUCTIONS.
• APPLIANCE MUST BE INSTALLED WITH PEDESTAL OR LEG KIT ATTACHED.
• OPTIONAL COMPONENTS - FAN KIT, FAN ELECTRICAL RATING: 115V, 60HZ, 1.0 AMP.
• CAUTION: RISK OF EXCESSIVE TEMPERATURES - KEEP ASH DUMP CLOSED DURING FIRING OF THE
HEATER. • DO NOT ROUTE POWER CORD UNDER HEATER.
• OPERATE ONLY WITH FEED DOOR CLOSED. OPEN TO FEED FIRE ONLY.
• KEEP FURNISHINGS AND OTHER COMBUSTIBLE MATERIALS WELL AWAY FROM HEATER.
• REPLACE GLASS ONLY WITH CERAMIC GLASS.
AS TESTED - PIPE SHIELD MAY BE REQUIRED BY LOCAL AUTHORITIES.
* ALCOVE SIZE : DEPTH - 3 FT. / .91 M MAX., HEIGHT 7 FT. / 2.1 M MIN.,
• COMBUSTIBLE FLOOR MUST BE PROTECTED BY A CONTINUOUS NON-COMBUSTIBLE MATERIAL
EXTENDED TO THE FRONT, SIDES AND BACK AS INDICATED.
• THIS WOOD HEATER NEEDS PERIODIC INSPECTION AND REPAIR FOR PROPER OPERATION. -
CONSULT THE OWNER’S MANUAL FOR FURTHER INFORMATION.
• IT IS AGAINST FEDERAL REGULATIONS TO OPERATE THIS WOOD HEATER IN A MANNER
INCONSISTANT WITH THE OPERATING INSTRUCTIONS IN THE OWNER’S MANUAL
ETL#4001507
• INSTALLEZ ET UTILISEZ SELON LES INSTRUCTIONS D’INSTALLATION ET D’OPÉRATION FOURNI AVEC L’APPAREIL..
• CONTACTEZ LES OFFICIELS DE LA CONSTRUCTION OU DE SERVICE D’INCENDIE POUR DES INFORMATIONS QUANT AUX
RESTRICTIONS. PERMIS D’INSTALLATION ET INSPECTIONS DANS VOTRE RÉGION.
• NE RELIEZ PAS CET APPAREIL À UN CONDUIT DE CHEMINÉE DESSERVANT DÉJÀ UN AUTRE APPAREIL
• UTILISEZ UN RACCORDEMENT NOIR OU CLASSÉ DE 24 MSG ET AVEC UN DIAMÈTRE D’AU MOINS 6 POUCES / 150 mm.
• PEUT ÊTRE CONNECTÉ À UNE CHEMINÉE DE MAÇONNERIE ALIGNÉE PRÊTE À L’EMPLOI AVEC DES COMBUSTIBLES
SOLIDES.
• N’OBSTRUEZ PAS L’ESPACE SOUS LE CAISSON DU POÊLE
• CONSULTEZ LE CODE LOCAL DE CONSTRUCTION ET LES INSTRUCTIONS DU FABRICANT QUANT AUX PRÉCAUTIONS À
PRENDRE LORSQUE VOUS FAITES PASSER UNE CHEMINÉE À TRAVERS D’UN MUR OU D’UN PLAFOND COMPOSÉS DE
MATÉRIAUX COMBUSTIBLES.
• NE FAITES PAS PASSER UN RACCORDEMENT DE CHEMINÉE À TRAVERS D’UN MUR OU D’UN PLAFOND COMPOSÉS DE
MATÉRIAUX
• DÉGAGEMENT MINIMAL ENTRE UN RACCORDEMENT DE CHEMINÉE À UN MUR SIMPLE ET TOUT MATÉRIEL COMBUSTIBLE
- 18 POUCES / 455 mm. CE DÉGAGEMENT PEUT ÊTRE RÉDUIT EN UTILISANT DES PROTECTEURS DE TUYAUX CLASSÉS,
PROTECTEURS DE MUR OU AUTRES MOYENS APPROUVÉS PAR LES OFFICIELS DE LA CONSTRUCTION OU DU SERVICE
D’INCENDIE DE VOTRE RÉGION.
CONNECTEUR HORIZONTAL NON PERMIS DANS MAISONS MOBILES
• L’APPARIEL DOIT COMPORTER UN ENSEMBLE POUR PIEDSTABLE OU SUR PATTES.
• PIÈCES REQUISES POUR INSTALLATION EN MAISON MOBILE OU EN ALCÔVE: NÉCESSAIRE
D’APPROVISIONNEMENT D’AIR EXTÉRIEUR ET L’UN DES RACCORDS SUIVANTS: EN COMBINAISON
AVEC L’UN DES SYSTÈMES DE CHEMINÉE COMPATIBLES SUIVANTS:
AU CANADA - LE ULC S-641 CONNECTEUR ENUMERES ET ULC-S-629 ONT ENUMERE CHEMINEE
• PIÈCES EN OPTION - NÉCESSAIRES DE SOUFFLERIE, INDICES ÉLECTRIQUES DE SOUFFLERIE: 115V, 60HZ, 1.0 AMP. LE FIL
ÉLECTRIQUE NE DOIT PAS ÊTRE PLACÉ SOUS LE POÈTE. • LE FIL ÉLECTRIQUE NE DOIT PAS ÊTRE PLACÉ SOUS LE POÊLE
• ATTENTION: RISQUE DE TEMPÉRATURES EXCESSIVES - GARDES LE TIROIR DE CENDRES FERMÉ PENDANT L’ALLUMAGE
DU POÈTE.
• OPÉREZ SEULEMENT LORSQUE LA PORTE D’ALIMENTATION EST FERMÉE. • OUVREZ SEULEMENT POUR ALIMENTER LE FEU.
• GARDEZ LES MEUBLES ET AUTRES MATÉRIAUX COMBUSTIBLES BIEN ÉLOIGNÉS DU POÊLE.
• REMPLACES LA VITRE AVEC UNIQUEMENT DE LA VITRE CÉRAMIQUE.
CONNECTEUR HORIZONTAL NON PERMIS DANS MAISONS MOBILES
TEL QUO ÉPROUVÉ UN PROTECTEUR DE TUYAU PEUT ÊTRE REQUIS PAR LES AUTORITÉS LOCALES
* DIMENSION D’ALCOVE COMBUSTIBLE: PROFONDEUR - 3 PIEDS / .91M, HAUTEUR 7 PIEDS/2.1M, LARGEUR 4 PIEDS/1.2M
MINIMUM.
LE PLANCHER COMBUSTIBLE DOIT ÊTRE PROTÉGÉ PAR UN MATÉRIEL NON-COMBUSTIBLE TOUT D’UNE PIÈCE QUI DOIT
S’ÉTENDRE DE PAR LE DEVANT, LES COTÉS ET L’ARRIÈRE TEL QU’INDIQUÉ.
CET APPRAREIL DE CHAUFFAGE AU BOIS DOIT FAIRE L’OBJETD’ENTRETIENS ET D’INSPECTIONS P
É
RIODIQUES
POUR UN FONCTIONNEMENT AD
É
QUAT. CONSULTEZ LE MANUEL D’UTILISATION POUR PLUS D’INFORMATION.
MADE IN CANADA/
FABRIQUÉ AU CANADA
SUPER LE100001350300418
MANUFACTURED BY/
FABRIQUÉ PAR:
PACIFIC ENERGY FIREPLACE PRODUCTS LTD.
2975 ALLENBY RD., DUNCAN, BC V9L 6V8
DO NOT REMOVE THIS LABEL
U.S. ENVIRONMENTAL PROTECTION AGENCY.
Certifi ed to comply with 2020 CRIB WOOD PARTICULATE EMISSION
STANDARDS, using Method 28R//
Certifi é conforme aux normes sur les
émissions de particules de 2020.
1.8 g/hr
MINIMUM CLEARANCES TO
COMBUSTIBLE MATERIALS/
DÉGAGEMENTS MINIMALES AUX
MATÉRIAUX COMBUSTIBLES
RESIDENTIAL / MOBILE HOME
INSTALLATION USING DOUBLE
WALL CONNECTOR/
INSTALLATION
RÉSIDENTIELLE AVEC DÉGAGEMENT
MINIMAL/
EN MAISON MOBILE
, UTILISANT UN
RACCORD DE MUR DOUBLE
RESIDENTIAL INSTALLATION
USING SINGLE WALL CONNECTOR/
INSTALLATION RÉSIDENTIELLE UTILISANT UN
RACCORD DE MUR SIMPLE
IN CANADA G. 18 INCHES / 455 MM
AU CANADA
H. 8 INCHES / 200 MM
I. 8 INCHES / 200 MM
IN U.S.A. G. 16 INCHES / 405 MM
H. 5 INCHES / 127 MM
I. 0 INCHES / 0 MM
A. SIDEWALL TO UNIT/
MUR DE CÔTE / APPAREIL
B. BACKWALL TO UNIT/
M
UR DE FOND / APPAREIL
C. CORNER TO UNIT/
COIN / APPAREIL
D. SIDEWALL TO CONNECTOR/
MUR DE CÔTE / RACCORD
E. BACKWALL TO CONNECTOR/
MUR DE FOND / RACCORD
F. CORNER TO CONNECTOR/
COIN / RACCORD
BACK I
HEATER
G
SIDE
H
FRONT
SIDE
H
COT E
COT E
DEVANT
POELE
DOS
A.
14 in. / 356 mm
B.
5 in. / 127 mm
C.
4 in. / 102 mm
SUPER
D.
23 in. / 585 mm
E.
12 in. / 305 mm
F.
15 in. / 370 mm
ALDERLEA T5
D.
23.5 in. / 595 mm
E.
12 in. / 305 mm
F.
18 in. / 460 mm
SN#
DATE OF MANUFACTURE
SUPER-LE_100323-28 3100001133
Produktspecifikationer
Varumärke: | Pacific Energy |
Kategori: | Värmare |
Modell: | Super Classic LE |
Behöver du hjälp?
Om du behöver hjälp med Pacific Energy Super Classic LE ställ en fråga nedan och andra användare kommer att svara dig
Värmare Pacific Energy Manualer
9 September 2024
9 September 2024
9 September 2024
9 September 2024
9 September 2024
8 September 2024
8 September 2024
8 September 2024
8 September 2024
8 September 2024
Värmare Manualer
- Värmare Zibro
- Värmare Candy
- Värmare Electrolux
- Värmare Bosch
- Värmare AEG
- Värmare Philips
- Värmare Bauknecht
- Värmare Delonghi
- Värmare Daewoo
- Värmare DeWalt
- Värmare Honeywell
- Värmare Quigg
- Värmare Zanussi
- Värmare Tefal
- Värmare Adler
- Värmare Alpina
- Värmare AKO
- Värmare Argo
- Värmare Ariete
- Värmare Invicta
- Värmare Bartscher
- Värmare Eurom
- Värmare Orbegozo
- Värmare Princess
- Värmare Gude
- Värmare Holmes
- Värmare Klarstein
- Värmare Fagor
- Värmare Severin
- Värmare Telefunken
- Värmare Gorenje
- Värmare Silvercrest
- Värmare Nedis
- Värmare Thomson
- Värmare Korona
- Värmare Black And Decker
- Värmare Bestway
- Värmare Innoliving
- Värmare Tristar
- Värmare Domo
- Värmare Trisa
- Värmare Vonroc
- Värmare Calor
- Värmare Rowenta
- Värmare Maestro
- Värmare Livoo
- Värmare Stanley
- Värmare Manta
- Värmare SereneLife
- Värmare Beurer
- Värmare Hyundai
- Värmare Vox
- Värmare Bestron
- Värmare ECG
- Värmare Sinbo
- Värmare Izzy
- Värmare Ryobi
- Värmare Jata
- Värmare Melissa
- Värmare Swan
- Värmare Emerio
- Värmare Scarlett
- Värmare Clatronic
- Värmare Taurus
- Värmare Russell Hobbs
- Värmare Sencor
- Värmare Midea
- Värmare Eureka
- Värmare Cuisinart
- Värmare Blaupunkt
- Värmare Concept
- Värmare Solac
- Värmare Sunbeam
- Värmare Parkside
- Värmare Svan
- Värmare Logik
- Värmare Danby
- Värmare Anslut
- Värmare Carson
- Värmare Elro
- Värmare Sun Joe
- Värmare EMOS
- Värmare Mesko
- Värmare EWT
- Värmare Beper
- Värmare Mellerware
- Värmare Nestor Martin
- Värmare Heinner
- Värmare Termozeta
- Värmare Vitek
- Värmare Eldom
- Värmare Einhell
- Värmare Fenix
- Värmare Cresta
- Värmare Kenmore
- Värmare Philco
- Värmare Defy
- Värmare Stiebel Eltron
- Värmare Infiniton
- Värmare Bionaire
- Värmare Maginon
- Värmare Otsein-Hoover
- Värmare Dometic
- Värmare Lasko
- Värmare Velleman
- Värmare Dimplex
- Värmare DCG
- Värmare Vemer
- Värmare Easymaxx
- Värmare Suntec
- Värmare Profile
- Värmare Ferroli
- Värmare Real Flame
- Värmare Solis
- Värmare Evolar
- Värmare Haeger
- Värmare Perel
- Värmare Steba
- Värmare Zibro Kamin
- Värmare Air King
- Värmare Proline
- Värmare Royal Sovereign
- Värmare Corberó
- Värmare King
- Värmare Ardes
- Värmare ETA
- Värmare Mora
- Värmare Olympia
- Värmare Piazzetta
- Värmare Soler And Palau
- Värmare Stadler Form
- Värmare Heylo
- Värmare Bomann
- Värmare GRE
- Värmare Kent
- Värmare Arnold Rak
- Värmare Cotech
- Värmare Ufesa
- Värmare CasaFan
- Värmare Wilfa
- Värmare Olimpia Splendid
- Värmare Trotec
- Värmare Enders
- Värmare Camry
- Värmare Wamsler
- Värmare Qlima
- Värmare Duux
- Värmare Imetec
- Värmare Alpatec
- Värmare Blaze
- Värmare Jocel
- Värmare Sygonix
- Värmare Atika
- Värmare Zodiac
- Värmare Primo
- Värmare Barbecook
- Värmare Creda
- Värmare Atlantic
- Värmare Trumatic
- Värmare MPM
- Värmare Hema
- Värmare Tectro
- Värmare Becken
- Värmare Plieger
- Värmare Mill
- Värmare Reer
- Värmare Zehnder
- Värmare Sogo
- Värmare Tesy
- Värmare Napoleon
- Värmare Essentiel B
- Värmare Mestic
- Värmare Chauvet
- Värmare Vivax
- Värmare Fantini Cosmi
- Värmare Nevir
- Värmare Prime3
- Värmare Blumfeldt
- Värmare CaterChef
- Värmare Kambrook
- Värmare Zephir
- Värmare Harvia
- Värmare Basetech
- Värmare Thermex
- Värmare Brixton
- Värmare Bimar
- Värmare Superior
- Värmare Kunft
- Värmare La Nordica
- Värmare Jotul
- Värmare HQ
- Värmare Vasco
- Värmare Fluval
- Värmare Noveen
- Värmare Master
- Värmare Nectre
- Värmare Fuxtec
- Värmare Nobo
- Värmare Astralpool
- Värmare Argoclima
- Värmare Cadel
- Värmare Baxi
- Värmare Conceptronic
- Värmare Eurolite
- Värmare Heller
- Värmare Vornado
- Värmare Sonnenkonig
- Värmare Waldbeck
- Värmare Grunkel
- Värmare Lavorwash
- Värmare Jaga
- Värmare Masport
- Värmare AENO
- Värmare Coleman
- Värmare REMKO
- Värmare Clean Air Optima
- Värmare Extraflame
- Värmare Toyotomi
- Värmare Lynx
- Värmare Tayosan
- Värmare Just Fire
- Värmare Optimum
- Värmare Broan
- Värmare Cecotec
- Värmare Hartig And Helling
- Värmare Kalorik
- Värmare Gutfels
- Värmare Crane
- Värmare Eden
- Värmare TAIDEN
- Värmare Brandson
- Värmare Veito
- Värmare Ecoteck
- Värmare Etherma
- Värmare Orava
- Värmare Nordic Fire
- Värmare Haas+Sohn
- Värmare Eurotronic
- Värmare Wanders
- Värmare Everdure
- Värmare Duronic
- Värmare Emga
- Värmare Heatstrip
- Värmare NewAir
- Värmare Escea
- Värmare Kogan
- Värmare Dedra
- Värmare Braemar
- Värmare Lenoxx
- Värmare Signature
- Värmare Martec
- Värmare Jindara
- Värmare Global
- Värmare Neo
- Värmare SPT
- Värmare Hatco
- Värmare SunRed
- Värmare Starlyf
- Värmare JANDY
- Värmare Aerian
- Värmare IXL
- Värmare XPower
- Värmare WestBend
- Värmare Hortus
- Värmare Prem-i-air
- Värmare Stenda
- Värmare VIESTA
- Värmare Vasner
- Värmare Brivis
- Värmare Hubbell
- Värmare HeatStar
- Värmare Dri Eaz
- Värmare Regency
- Värmare Burley
- Värmare Rinnai
- Värmare NEO Tools
- Värmare SHX
- Värmare Invroheat
- Värmare GoldAir
- Värmare Noirot
- Värmare Ouellet
- Värmare AccuLux
- Värmare Ravanson
- Värmare Gossmann
- Värmare Wulfe
- Värmare Create
- Värmare Duro Pro
- Värmare Herschel
- Värmare Casaya
- Värmare HyCell
- Värmare TURBRO
- Värmare Radialight
- Värmare Sunheat
- Värmare Heidenfeld
- Värmare Hcalory
- Värmare Rowi
- Värmare Neopower
- Värmare Arlec
- Värmare Guardian
- Värmare Big Ass Fans
- Värmare United
- Värmare Pureheat
- Värmare EvoHeat
- Värmare DCS
- Värmare Bromic
- Värmare MSW
- Värmare Solamagic
- Värmare Contura
- Värmare Mirpol
- Värmare FIAP
- Värmare Alkari
- Värmare Ausclimate
- Värmare Longvie
- Värmare Blue Rhino
- Värmare Brentwood
- Värmare Rheem
- Värmare Gasmate
- Värmare Ionmax
- Värmare Airo
- Värmare Mission Air
- Värmare Omega Altise
- Värmare Scandia
- Värmare Fire Sense
- Värmare InfraNomic
- Värmare Heat Storm
- Värmare Excelair
- Värmare Heatscope
- Värmare LifeSmart
- Värmare Heat1
- Värmare Thermotec
- Värmare Kemlan
- Värmare Yellow Garden Line
- Värmare Perfect Aire
- Värmare AustWood
- Värmare Uniprodo
- Värmare Yamazen
- Värmare Infratech
- Värmare TANSUN
- Värmare Universal Blue
Nyaste Värmare Manualer
22 December 2024
22 December 2024
22 December 2024
22 December 2024
21 December 2024
21 December 2024
21 December 2024
21 December 2024
21 December 2024
21 December 2024