For Technical Support: www.panduit.com/resources/install_maintain.asp
INSTALLATION INSTRUCTIONS
© Panduit Corp. 2013 PN581
Page 1 of 3
TX6A 10Gig, TX6 PLUS and TX5e UTP
Jack Modules with Right Angle Wire Cap
Part Numbers: CJR6X88TG**, CJR688TG**, CJR5E88TG**
CJR6X88TG** CJR688TG** CJR5E88TG**
Jack
Right Angle
Wire Cap
** Denotes color.
A
B
A
B
A
B
A
B
IMPORTANT!: Determine the desired direction of cable before
wiring the cap. The cap, in relation to the jack, must be kept
consistent throughout the entire termination.
Understanding the Label
2a 2b
3a
1
4a
5a
3b
4b
1
2
5b
Do not pre-arrange
conductors.
(OR)
Bend wires to
ease inserting
them into the
cap.
Do not pre-arrange
conductors.
(OR)
Bend wires to
ease inserting
them into the
cap.
INSTALLATION INSTRUCTIONS
© Panduit Corp. 2013 PN581
For Technical Support: www.panduit.com/resources/install_maintain.asp
Page 2 of 3
A
A
A
A
B
B
B
B
B
B
B
B
6a T568B Wiring
(OR)
Termination side Label side
T568A Wiring
Termination side Label side
A
A
A
A
(OR)
1.
1. 2.
1.
1. 2.
2.
A
A
A
A
B
B
1.
1. 2.
A
A
A
A
B
B
B
B
6b T568B Wiring
(OR)
Termination side Label side
T568A Wiring
Termination side Label side
(OR)
B
B
1.
1. 2.
2.
For Instructions in Local Languages
and Technical Support:
www.panduit.com/resources/install_maintain.asp www.panduit.com
E-mail:
techsupport@panduit.com
Phone:
866-405-6654
INSTALLATION INSTRUCTIONS
© Panduit Corp. 2013 PN581
Page 3 of 3
Notes:
1. For specified performance, follow TIA/EIA 568-C installation guidelines.
2. Jack Modules can terminate 22-26 AWG solid or stranded IWC data cable with 0.062" (1.57mm) maximum insulated conductor outside diameter.
3. Jack Modules may be re-terminated a minimum of 20 times.
4. For technical and performance information, consult Panduit Technical Support.
As with all Wiring Accessories, the following statements apply:
1. Never install communications wiring during a lightning storm.
2. Never install communications wiring in wet locations unless the jack is specifically designed for use in wet locations.
3. Never touch uninsulated communications wiring or terminals unless the communication line has been disconnected at the network interface.
4. Use caution when installing or modifying communication wiring.
1
2
3
REMOVAL STEPS
7
8
EGJT
9Important!
Maintain orientation of
cap in relation to jack
from previous steps.
11
10