Plugwise Scan Bruksanvisning
Läs nedan 📖 manual på svenska för Plugwise Scan (5 sidor) i kategorin Diverse klimatkontroll. Denna guide var användbar för 7 personer och betygsatt med 4.5 stjärnor i genomsnitt av 2 användare
Sida 1/5

Scan
200.106.110211
Presence detecon
Manual

2 3
Scan Manual
Thank you for buying this extension to your Plugwise system.
The Scan enables you to detect people’s presence by means of
an IR sensor and to switch appliances and lighng on and o
when people are or are not present in a room. The wireless
Scan is baery operated and communicates measurement
data by means of the Plugwise ZigBee protocol. This does
not require the computer to be le on. The Scan also has a
‘daylight override’ opon to switch lights o automacally
if the ambient light intensity is above a specied value for a
certain period (the override opon is switched o as standard).
This manual describes the installaon of a single Scan, but the
same steps can be followed if you want to install mulple Scans
at the same me.
Before you start
• Werecommendthatyoufollowthismanualcarefully;itisessenal
totakethestepsinthecorrectorder.
• To be able touse the Scan, youwill requirea Plugwise network
consisngofatleastaSckorStretchandaCircle+.
A Plugwise network can never contain more Scans than 5 mes the number
of Circles. What this manual explains for the Circle also applies to the
Stealth and the Sng, or a combinaon thereof.
• Ensure that you use the latest version of Source and that your
moduleshavethelatestrmwareversion.Youcancheckthisbyclicking
theUpdatesbuoninSource.TheScanisonlysupportedifallother
moduleshavermwareversion2.36(asof13-05-2011)orlater.Ifthisis
notyetthecase,priortotheinstallaonoftheScan,theothermodules
mustrstbeupdated.InSource,checkwhethertheSckandallofthe
modulesareonline.
• InSource,checkwhethertheckattheboomleofthescreen
showsthattheSckisonline:
• InSource,checkinthetreeat‘Overviews’toseewhetheralldevices
areonline.Thisisindicatedbygreyandyellowlights:
• OnlyinsertthebaerywhenyoustarttousetheScan.AScanuses
agreatdealmorepowerifitisnotconnectedtoaPlugwisenetwork.
• TousetheScan,itmustbeconnectedtoaPlugwisenetwork.Finally,
theScanmustbemountedontheceiling.Thesestepsareexplainedin
moredetailbelow.
• Check whether all components are present. If a component is
missing,pleasecontactusassoonaspossible.
Contents of the package
• PerScan:
ScanMounng plate
Scan
200.106.110211
Manual
1 3,6V AA baery This manual

4 5
1. Adding the Scan to your
Plugwise network
Ì AddingtheScantoyourPlugwisenetwork.
When you are asked to select a network, select the network to which the
Scan must be added.
Ì FillintheIDoftheScan.ThisIDisindicatedonthesckersthatare
aachedtotheback.
Ì Clickthebuonwiththegreenarrow:Next,inserttheAA
baeryintheScan,makingnoteofthe+and–marks.
Ì IfyouwanttoinstallmulpleScans,youcanaddtheIDsforallof
theScanstothelist.ThePlugwisenetworkwillthensearchforthe
ScanswiththenewIDsinthelist.WaitunlSourceindicatesthatthe
Scanisonline.Thecirclewiththequesonmarkwillthenchangeinto
thefollowingicon:
If the Scan is not found within several minutes, check whether the
Plugwise network is operang correctly (refer to ‘Before you start’). If the
Sck and the other modules are available in Source and the Scan is sll
not shown as being online, follow the instrucons to delete the network
sengs under ‘Delete network sengs’, see: ‘Advanced use’.
Ì Click‘Next’andthen‘Finish’.
TheScanisnowconnectedtoyournetwork.
2. Attaching the Scan to the ceiling
Ì TaketheScantothelocaonwhereitmustbeinstalled.TheScan
must always be in contact with its ‘parent’ (for example, a Circle),
otherwise no communicaon can take place. Addionally, to ensure
properfunconingoftheScan,itshouldbeinstalledinalocaonwhere
itisnotexposedtodirectsunlightorcarheadlightsandmustnotbe
directlyexposedtoanaircondionerorcentralheang/heater.
Ì ThisScanhasthefollowingsensivitysengs:
ÌHighsensivity(parcularlysuitedtooceenvironments)
ÌMediumsensivity(mainlyforhomeuse)
ÌO
Thefollowinggureshowstherangeforthersttwosengsforvarious
degreesofregisteredmovements(forwalkingordeskwork)atvarious
opmalinstallaonheights.
Ì CheckwhetherSourcesllindicatesthattheScanisonline.Itcan
takeseveralminutesforthenetworktoprocessthenewlocaonofthe
Scan.
Ì Aach the Scan mounng plate to the ceiling. The Up/Window
arrowontheinsideofthemounngplateindicatesthetop.Ensurethat
thePlugwiselogoonthefrontendsupinahorizontalposion:
Up/Window >
< Reset
Ì Whenthemounngplateisaachedtotheceiling,slidetheScan
fromaboveontotheplateunlyoufeeltheScanclickintoplace.
4.50 m
3.50 m
6 m
high sensivity
medium sensivity
2.40 m
2.70 m
Produktspecifikationer
Varumärke: | Plugwise |
Kategori: | Diverse klimatkontroll |
Modell: | Scan |
Behöver du hjälp?
Om du behöver hjälp med Plugwise Scan ställ en fråga nedan och andra användare kommer att svara dig
Diverse klimatkontroll Plugwise Manualer

13 September 2024

13 September 2024

12 September 2024

11 September 2024

11 September 2024
Diverse klimatkontroll Manualer
- Diverse klimatkontroll ATAG
- Diverse klimatkontroll Bosch
- Diverse klimatkontroll AEG
- Diverse klimatkontroll Gigaset
- Diverse klimatkontroll Honeywell
- Diverse klimatkontroll Inventum
- Diverse klimatkontroll Junkers
- Diverse klimatkontroll Nefit
- Diverse klimatkontroll Siemens
- Diverse klimatkontroll Vaillant
- Diverse klimatkontroll A.O. Smith
- Diverse klimatkontroll Argo
- Diverse klimatkontroll Edimax
- Diverse klimatkontroll Eurom
- Diverse klimatkontroll Theben
- Diverse klimatkontroll Elektrobock
- Diverse klimatkontroll Stiebel Eltron
- Diverse klimatkontroll Buderus
- Diverse klimatkontroll Elco
- Diverse klimatkontroll Dimplex
- Diverse klimatkontroll Easymaxx
- Diverse klimatkontroll Salus
- Diverse klimatkontroll Trotec
- Diverse klimatkontroll SMA
- Diverse klimatkontroll Danfoss
- Diverse klimatkontroll AWB
- Diverse klimatkontroll Xavax
- Diverse klimatkontroll Gira
- Diverse klimatkontroll Vasco
- Diverse klimatkontroll Sonnenkonig
- Diverse klimatkontroll Polti
- Diverse klimatkontroll REMKO
- Diverse klimatkontroll Brink
- Diverse klimatkontroll Sungevity
- Diverse klimatkontroll Mastervolt
- Diverse klimatkontroll Oregon Scientific
- Diverse klimatkontroll RAINBIRD
- Diverse klimatkontroll Muller
- Diverse klimatkontroll VC Trade
- Diverse klimatkontroll Skytech
- Diverse klimatkontroll Riello
- Diverse klimatkontroll MCZ
- Diverse klimatkontroll Ygnis
- Diverse klimatkontroll Kaysun
- Diverse klimatkontroll Frigicoll
- Diverse klimatkontroll Nuon
- Diverse klimatkontroll Renusol
- Diverse klimatkontroll Progenion
- Diverse klimatkontroll Technea
- Diverse klimatkontroll HRSolar
- Diverse klimatkontroll DGFlow
- Diverse klimatkontroll Premix
Nyaste Diverse klimatkontroll Manualer

21 Oktober 2024

20 Oktober 2024

5 Oktober 2024

20 September 2024

19 September 2024

17 September 2024

15 September 2024

15 September 2024

15 September 2024

15 September 2024