REDARC Smart Start SBI12D Bruksanvisning

REDARC Inte kategoriserad Smart Start SBI12D

Läs nedan 📖 manual på svenska för REDARC Smart Start SBI12D (11 sidor) i kategorin Inte kategoriserad. Denna guide var användbar för 2 personer och betygsatt med 4.5 stjärnor i genomsnitt av 2 användare

Sida 1/11
Smart Start®
Battery Isolator
SBI12, SBI24
SBI212, SBI224
& dual sensing models
THE SMART START® SBI
The Smart Start® SBI is a microprocessor controlled Smart Battery Isolator. The Smart Start
® SBI is
designed specifi cally for use in multi battery applications as a solenoid priority system to protect the
start battery from being excessively discharged by auxiliary loads, whilst still allowing the auxiliary
battery to supply non essential loads. Put simply, once the start battery has had some charge from the
alternator, the Smart Start® SBI will connect an auxiliary battery to the charge circuit. Similarly, if the
start battery voltage drops too low, the Smart Start
® SBI will disconnect any auxiliary batteries or loads
from the start battery to conserve charge.
SPECIFICATIONS
Part Number SBI12 (D)* SBI24 (D)* SBI212 (D)* SBI224 (D)*
System Voltage 12V 24V 12V 24V
ON Volts 13.2V 26.4V 13.2V 26.4V
OFF Volts 12.7V 25.4V 12.7V 25.4V
Turn ON Delay 5 sec 5 sec 5 sec 5 sec
Turn OFF Delay 10 sec 10 sec 10 sec 10 sec
Max. Cont. Current 100 Amps 100 Amps 200 Amps 200 Amps
Max. Inrush Current 400 Amps 400 Amps 600 Amps 600 Amps
Standby Current < 5mA < 5mA < 5mA < 5mA
Dimensions 75x70x80mm 90x95x100mm
Weight 200g 600g
Warranty 2 years
Standards CE, C-Tick, AS/NZS CISPR11:2004
*D indicates “Dual Sensing” which is described on page 4.
CABLE SIZE, CIRCUIT BREAKER(CB)/FUSE SIZE AND STUD TORQUE CHART
Model Wire
Length
Start Feature with
Pushbutton Override
No Override Main Stud
Torque
CB or Fuse Wire CB or Fuse Wire
SBI12/
SBI24
Up to 3m 100 Amps 19mm² (4B&S) 60 Amps 8mm² (8B&S) 5 - 6.2 Nm
3m to 6m 100 Amps 32mm² (2B&S) 60 Amps 13mm² (6B&S) 5 - 6.2 Nm
SBI212/
SBI224
Up to 3m 200 Amps 32mm² (2B&S) 120 Amps 19mm² (4B&S) 6.5Nm max
3m to 6m 200 Amps 40mm² (1B&S) 120 Amps 25mm² (3B&S) 6.5Nm max
1
SAL.FOR.Instruction Manual.SBI – DOC424 – Version 12
2
INSTALLATION INSTRUCTIONS
1. Mount the Smart Start® SBI securely in a convenient location near the start battery bank. Do not
mount in direct engine heat.
2. Install in the order described below:
Make sure the auxiliary battery negative is properly grounded to the vehicle chassis (1)
Ground Connection. Connect the Smart Start
® SBI ground terminal to chassis ground. Remove
any paint to ensure a good ground connection. Note: A good ground will ensure correct switching
voltage. (2)
Select correct Circuit Breaker/Fuse sizes and install at battery end of both positive cables (3)
Connect the cables in the order shown on the next page (4,5,6,7)
LED Connections (optional). Connect a wire from the Blue wire of the Smart Start
® SBI to the
positive end of an indicator LED (15mA limited current draw) or LED/resistor combination mounted
on the dash as specifi ed in the diagram on page 3.
Start Assist Feature (optional). Connect a wire from the Blue wire of the Smart Start
® SBI to one
terminal of a momentary push button switch. Connect the other terminal of the momentary push
button switch to the auxiliary battery supply. To manually operate the Smart Start
® SBI, hold the
momentary push button switch and the Smart Start
® SBI will manually operate until the switch is
released. After about 10 seconds start the vehicle with the button still held on.
Checking the Operation: The Smart Start
® SBI should now be operational. Start the vehicle or
apply a charge to the start battery. Once the start battery voltage rises to the ‘ON Voltslevel
the Smart Start® SBI will activate, you will hear the solenoid click and see the LED illuminate.
Now turn off the vehicle or remove the charger from the start battery. The Smart Start
® SBI will
disconnect the auxiliary battery once the voltage on the start battery drops to the OFF Volts level,
you will hear the solenoid click and the LED will go out. Note: The amount of time it takes for the
battery voltage to drop low enough for the solenoid to turn off will vary due to battery condition,
age and state of charge. (For a new, fully charged battery, it may take days). Note: See table on
page 1 for specifi c voltage levels.
NOTE: As per above, the LED may stay ON for a period of time after the vehicle is turned OFF.
RECOMMENDED FUSES
REDARC recommend using MIDI fuses along with a quality fuse holder to match. The diagram below
shows the construction of a MIDI fuse installation (cables not included).
REDARC MIDI fuse kits containing 4x fuses and 2x fuse
holders along with the required nuts are available from
most Auto Electrical outlets.
Part Numbers:
FK60 60A fuse kit
FK100 100A fuse kit

Produktspecifikationer

Varumärke: REDARC
Kategori: Inte kategoriserad
Modell: Smart Start SBI12D

Behöver du hjälp?

Om du behöver hjälp med REDARC Smart Start SBI12D ställ en fråga nedan och andra användare kommer att svara dig




Inte kategoriserad REDARC Manualer

Inte kategoriserad Manualer

Nyaste Inte kategoriserad Manualer