Rossmax X9 BT Bruksanvisning
Rossmax
Blodtrycksmätare
X9 BT
Läs nedan 📖 manual på svenska för Rossmax X9 BT (13 sidor) i kategorin Blodtrycksmätare. Denna guide var användbar för 4 personer och betygsatt med 4.5 stjärnor i genomsnitt av 2 användare
Sida 1/13
www.rossmax.com
Model: X9
Blood Pressure Monitor
2
Blood pressure measurements determined with X9 are equivalent to those obtained by
a trained observer using cu/stethoscope auscultation method, within the limits pre-
scribed by the American National Standard, Electronic or Automated Sphygmomanom-
eters. This unit is to be used by adult consumers in home, physicians’ oces, hospitals,
clinics and other medical facilities. The patient is an intended operator. Do not use this
device on infants or neonates. X9 is protected against manufacturing defects by an es-
tablished International Warranty Program. For warranty information, you can contact
the manufacturer, Rossmax International Ltd.
Attention: Consult the accompanying documents. Please read this manual care-
fully before use. For specic information on your own blood pressure, contact your
physician. Please be sure to keep this manual.
Introduction
PARR(Pulse Arrhythmia) Technology
The upper chambers of the heart (the atria) do not contract, but quiver and thus blood
is driven irregularly and with lower eciency into the ventricles. Subsequently irregular
heartbeats occurs, which mostly are associated with a fast, yet highly instable heart rate.
Pulse Arrhythmia (PARR) technology specically detects the existence of pulse arrhyth-
mia, including atrial brillation (AFib), Atrial and / or Ventricular Premature Contractions
(PC), Tachycardia (TACH), and Bradycardia (BRAD). Pulse Arrhythmia may be related to
cardiac disorders, needs medical attention and thus early diagnosis is of paramount
importance. The PARR technology detects arrhythmia during regular blood pressure
checks without any additional user skills, user interaction and measurement prolonga-
tion. Beside the blood pressure diagnosis a specic pulse arrhythmia diagnosis is pro-
vided with PARR.
Note: The PARR detection of AFib, PC, TACH and BRAD is provided with a clinically
proven high detection probability [1]. However, the sensitivity and specicity is
limited, thus most, but not all pulse arrhythmia will be detected and displayed.
In certain patients with uncommon clinical conditions the PARR technology may
not be able to detect pulse arrhythmia. This partly comes from the fact that some
arrhythmia can only be found with an ECG diagnosis, but not with a pulse diagno-
sis. Thus PARR is not meant to replace any medical ECG diagnosis by your doctor.
PARR provides an early detection of certain pulse arrhythmia, which inevitably
need to be presented to your doctor in charge.
Remark: [1] Clinical Investigation of PARR - A new Oscillometric Pulse Arrhythmia Type
Discriminating Detection Technology
Atrial Fibrillation Detection (AFib)
4
A fast heart rate of higher than 100 beats per minute (bpm) in adults. Unless being
caused by physical or mental stress, a tachycardia may be an indicator for both cardiac
(e.g. Coronary heart disease, valvular disorder), or extra-cardiac disorders (e.g. hyperthy-
roidism, fever, hypoxemia), as well as medication and stimulant substance side eects
(e.g. caeine). The unit is able to detect Tachycardia (TACH). The ARR and TACH icons (
) are displayed right after the measurement if tachycardia has been detected.
Note: It is strongly recommended, that you consult your physician, if either the TACH
icon occurs newly for several times, or, if your TACH is known to your doctor, but
the incidence of TACH readings changes over time. Your doctor will then be able
to provide all required medical test and possible therapeutic procedures.
Tachycardia Detection (TACH)
A slow heart rate of less than 55 beats per minute (bpm) in adults. Unless not genetically
determined or subsequent to a high cardiac endurance training adaptation, bradycar-
dia may be related to multitude of cardiac disorders (e.g. valvular heart disease, heart
failure) or extra-cardiac disorders (e.g. hypothyroidism, electrolyte imbalance) or medi-
cations (e.g. beta-receptor blocker). This unit is able to detect Bradycardia (BRAD). The
ARR and BRAD icons ( ) are displayed right after the measurement if bradycar-
dia was detected.
Note: It is strongly recommended, that you consult your physician, if either the BRAD
icon occurs newly for several times, or, if your BRAD is known to your doctor, but
the incidence of BRAD readings changes over time. Your doctor will then be able
to provide all required medical test and possible therapeutic procedures.
Bradycardia Detection (BRAD
Once the occurrence of pulse arrhythmia has been detected in the course of your blood
pressure measurement, the icon ARR is displayed. In the case, that the found pulse ar-
rhythmia can be specied by the PARR technology, the ARR icon is accompanied by the
specically detected type of arrhythmia, e.g. PC, AFib, TACH or BRAD. Once the kind of
found pulse arrhythmia cannot be safely determined by PARR, the device is displaying
ARR without any additional pulse arrhythmia type icon.
Note: It is strongly recommended, that you consult your physician, if either the ARR icon
occurs newly for several times, or, if your ARR is known to your doctor, but the in-
cidence of ARR readings changes over time. This is independent whether the ARR
icon is specied by another pulse arrhythmia icon or not. Your doctor will then
be able to provide all required medical test and possible therapeutic procedures.
Pulse Arrhythmia Detection (ARR)
Produktspecifikationer
Varumärke: | Rossmax |
Kategori: | Blodtrycksmätare |
Modell: | X9 BT |
Behöver du hjälp?
Om du behöver hjälp med Rossmax X9 BT ställ en fråga nedan och andra användare kommer att svara dig
Blodtrycksmätare Rossmax Manualer
18 Oktober 2024
21 September 2024
21 September 2024
21 September 2024
10 September 2024
6 September 2024
5 September 2024
5 September 2024
31 Augusti 2024
21 Augusti 2024
Blodtrycksmätare Manualer
- Blodtrycksmätare Braun
- Blodtrycksmätare Panasonic
- Blodtrycksmätare Nokia
- Blodtrycksmätare Topcom
- Blodtrycksmätare AnD
- Blodtrycksmätare Aponorm
- Blodtrycksmätare Silvercrest
- Blodtrycksmätare Nedis
- Blodtrycksmätare Thomson
- Blodtrycksmätare Tristar
- Blodtrycksmätare Trisa
- Blodtrycksmätare Beurer
- Blodtrycksmätare Clatronic
- Blodtrycksmätare Taurus
- Blodtrycksmätare Sencor
- Blodtrycksmätare Solac
- Blodtrycksmätare Medisana
- Blodtrycksmätare Omron
- Blodtrycksmätare Citizen
- Blodtrycksmätare Cresta
- Blodtrycksmätare Marquant
- Blodtrycksmätare Visomat
- Blodtrycksmätare Homedics
- Blodtrycksmätare Sanitas
- Blodtrycksmätare Microlife
- Blodtrycksmätare Welch Allyn
- Blodtrycksmätare Laica
- Blodtrycksmätare Boso
- Blodtrycksmätare Konig
- Blodtrycksmätare Mx Onda
- Blodtrycksmätare IHealth
- Blodtrycksmätare Withings
- Blodtrycksmätare Etekcity
- Blodtrycksmätare Ecomed
- Blodtrycksmätare Magic Care
- Blodtrycksmätare Elta
- Blodtrycksmätare Medel
- Blodtrycksmätare Geratherm
- Blodtrycksmätare Truelife
- Blodtrycksmätare Heine
- Blodtrycksmätare Bioland
- Blodtrycksmätare Orava
- Blodtrycksmätare Levita
- Blodtrycksmätare Scala
- Blodtrycksmätare Silvergear
- Blodtrycksmätare Uebe
- Blodtrycksmätare Duronic
- Blodtrycksmätare MTLogic
- Blodtrycksmätare Hartmann
- Blodtrycksmätare Kinetik
- Blodtrycksmätare Eks
- Blodtrycksmätare Gima
- Blodtrycksmätare Time 2
- Blodtrycksmätare My Life My Shop
- Blodtrycksmätare Welby
- Blodtrycksmätare Sendo
- Blodtrycksmätare Oro-Med
- Blodtrycksmätare A&D
- Blodtrycksmätare Dr. Senst
Nyaste Blodtrycksmätare Manualer
21 Oktober 2024
20 Oktober 2024
18 Oktober 2024
18 Oktober 2024
16 Oktober 2024
16 Oktober 2024
14 Oktober 2024
13 Oktober 2024
10 Oktober 2024
10 Oktober 2024