Sanibroyeur Sanipump ZPG 71 Bruksanvisning
Sanibroyeur
Pomp
Sanipump ZPG 71
Läs nedan 📖 manual på svenska för Sanibroyeur Sanipump ZPG 71 (18 sidor) i kategorin Pomp. Denna guide var användbar för 4 personer och betygsatt med 4.5 stjärnor i genomsnitt av 2 användare
Sida 1/18

SANIPUMP®ZPG71
9035
02.20
EN
Submersible greywater pump • Operating/installation manual
DE
Abwasser-Tauchpumpe • Bedienungs-/Installationsanleitung
FR
Pompe submersible pour évacuation des eaux grises
•
Notice de service/montage
ES
Bomba sumergible para aguas residuales • Manual de funcionamento
IT
Pompa sommersa per acque reflue • Manuale per l’uso e l’installazione
NL
Afvalwater-dompelpomp • Gebruikers-/installatiehandleiding
PT
Bomba submersível para águas residuais •
Manual de instalação/utilização

English 3 ......................................
Deutsch 14 .....................................
Français 26 ....................................
Italiano 38 .....................................
Nederlands 50 ................................
Español 62 .....................................
Português 74 .................................

10
- Sound out position of guide pipe frame for coupling pedestal, adjust coupling pedestal on shaft bottom and
mount it with the heavy-duty dowels which are included in the delivery.
- Install pressure pipe and valves in a tension-free manner.
- Slip the guide pipe on the coupling pedestal, shorten it to correct length, slip on pipe clamp and tighten it for good.
- Mount coupling element and lowering chain to the pump, lower pump with the chain (insert guide pipe into
coupling element) and couple it, hang the chain up on the pipe clamp so that it is ready to hand.
- Lay supply cable. Avoid kinks and lay supply cable without tensile loading and without causing chafe marks.
5.3 Level control system
The pumps SANIPUMP® ZPG 71 have to be controlled by means of a level control in such a way, that a
decline of the water level beneath the minimum allowable level (bottom line of motor housing) is avoided at
all costs.
The level control can be effected by means of a floating switch, electropneumatically (press switch) or by
means of other applicable methods. The switching point of the pump should be set in such a way, that the
pump is entirely submersed under water.
6. COMMISSIONING
Check all connections for correct assembly, set gate valve on passage and check level control system
for proper operation.
During the initial test run, check pipes for tightness and reseal them, if necessary.
7. MAINTENANCE AND REPAIR
Disconnect the power supply before carrying out any kind of
work on the plant!
After an operation time of six to twelve months, the oil storage inside the seal carrier always has to be
controlled as follows:
- put the pump on its side on a clean surface and position it in such a way that the oil filling screw faces upwards,
- take out the screw and check the oil level.
If only a small quantity of oil is lacking, the oil storage can be filled up without any problems. If a
considerable quantity of oil is lacking, or if the oil is mingled with water, the customer department has
to be informed.
All other maintenance works on the pump and on the electrical equipment should be carried out by the
manufacturer or an authorised qualified company in intervals of six to twelve months (or also in shorter
intervals, according to case of operation). Please immediately inform the customer department in case
of damage to the pump and/or the electrical equipment.
8. MALFUNCTIONS, CAUSES AND TROUBLESHOOTING
Disconnect the power supply before carrying out any kind of work
on the plant!
Produktspecifikationer
Varumärke: | Sanibroyeur |
Kategori: | Pomp |
Modell: | Sanipump ZPG 71 |
Behöver du hjälp?
Om du behöver hjälp med Sanibroyeur Sanipump ZPG 71 ställ en fråga nedan och andra användare kommer att svara dig
Pomp Sanibroyeur Manualer

30 December 2025

31 Augusti 2024

23 Augusti 2024

21 Augusti 2024

19 Augusti 2024

19 Augusti 2024

16 Augusti 2024

14 Augusti 2024
Pomp Manualer
- Pomp Karcher
- Pomp Nefit
- Pomp Vaillant
- Pomp Al-ko
- Pomp Vetus
- Pomp Bartscher
- Pomp Eurom
- Pomp Generac
- Pomp Ozito
- Pomp Gude
- Pomp Silvercrest
- Pomp Makita
- Pomp Black And Decker
- Pomp Bestway
- Pomp Vonroc
- Pomp Crivit
- Pomp Hyundai
- Pomp Ryobi
- Pomp Sicce
- Pomp Outwell
- Pomp Metabo
- Pomp Worx
- Pomp Milwaukee
- Pomp Sun Joe
- Pomp Tacklife
- Pomp Hazet
- Pomp Einhell
- Pomp Ultimate Speed
- Pomp SKS
- Pomp Gardena
- Pomp Hayward
- Pomp Eheim
- Pomp Nibe
- Pomp Ferroli
- Pomp Husqvarna
- Pomp Melinera
- Pomp Oase
- Pomp Biltema
- Pomp Powerplus
- Pomp Danfoss
- Pomp Michelin
- Pomp Scheppach
- Pomp Zodiac
- Pomp Powerfix
- Pomp Topeak
- Pomp Hozelock
- Pomp Bulex
- Pomp Technaxx
- Pomp Lezyne
- Pomp Fluke
- Pomp Blumfeldt
- Pomp For_Q
- Pomp Simpson
- Pomp Zipper
- Pomp Fieldmann
- Pomp WHALE
- Pomp Fluval
- Pomp Fuxtec
- Pomp Astralpool
- Pomp Abac
- Pomp Waldbeck
- Pomp Cannondale
- Pomp Lavorwash
- Pomp Coleman
- Pomp Testo
- Pomp Maruyama
- Pomp Jabsco
- Pomp Toolcraft
- Pomp Eufab
- Pomp Pontec
- Pomp Aerotec
- Pomp Batavia
- Pomp Gardenline
- Pomp Westfalia
- Pomp ESPA
- Pomp POLARIS
- Pomp Osram
- Pomp Pedrollo
- Pomp Park Tool
- Pomp Velda
- Pomp Vivaria
- Pomp Plantiflor
- Pomp Verto
- Pomp Little Giant
- Pomp Panduit
- Pomp Wetelux
- Pomp Germania
- Pomp Anova
- Pomp Ubbink
- Pomp DAB
- Pomp Esotec
- Pomp Wayne
- Pomp T.I.P.
- Pomp Rule
- Pomp JANDY
- Pomp Neptun
- Pomp Elpumps
- Pomp Hollex
- Pomp B-Air
- Pomp Baracuda
- Pomp Lifan
- Pomp Enermax
- Pomp Monzana
- Pomp Liberty Pumps
- Pomp BluGarda
- Pomp Alpha Tools
- Pomp Grundfos
- Pomp Madimack
- Pomp Sauermann
- Pomp Eco-Flo
- Pomp Nowax
- Pomp Zoeller
- Pomp Superior Pump
- Pomp SHURflo
- Pomp EvoHeat
- Pomp MSW
- Pomp OKAY
- Pomp FIAP
- Pomp Barwig
- Pomp Ribimex
- Pomp Ebara
- Pomp Perlick
- Pomp Basement Watchdog
- Pomp Ergotools Pattfield
- Pomp Zéfal
- Pomp Zehnder Pumpen
- Pomp Comet
- Pomp SANDPIPER
- Pomp Heissner
- Pomp Blackburn
- Pomp OSIP
- Pomp Franklin Electric
Nyaste Pomp Manualer

29 Mars 2025

29 Mars 2025

29 Mars 2025

29 Mars 2025

29 Mars 2025

29 Mars 2025

29 Mars 2025

29 Mars 2025

27 Mars 2025

27 Mars 2025