Data sheet
Data sheet
Data sheet
Data sheetData sheet 3RV2011-0HA10
3RV2011-0HA10
3RV2011-0HA10
3RV2011-0HA103RV2011-0HA10
Circuit breaker size S00 for motor protection, CLASS 10 A-release
0.55...0.8 A N-release 10 A screw terminal Standard switching
capacity
Product brand name
Product brand name
Product brand name
Product brand nameProduct brand name SIRIUS
Product designation
Product designation
Product designation
Product designationProduct designation Circuit breaker
Design of the product
Design of the product
Design of the product
Design of the productDesign of the product For motor protection
Product type designation
Product type designation
Product type designation
Product type designationProduct type designation 3RV2
General technical data
Size of the circuit-breaker
Size of the circuit-breaker
Size of the circuit-breaker
Size of the circuit-breakerSize of the circuit-breaker S00
Size of contactor can be combined company-specific
Size of contactor can be combined company-specific
Size of contactor can be combined company-specific
Size of contactor can be combined company-specificSize of contactor can be combined company-specific S00, S0
Product extension
Product extension
Product extension
Product extensionProduct extension
● Auxiliary switch Yes
Power loss [W] total typical
Power loss [W] total typical
Power loss [W] total typical
Power loss [W] total typicalPower loss [W] total typical 6W
Surge voltage resistance rated value
Surge voltage resistance rated value
Surge voltage resistance rated value
Surge voltage resistance rated valueSurge voltage resistance rated value 6kV
maximum permissible voltage for safe isolation
maximum permissible voltage for safe isolation
maximum permissible voltage for safe isolation
maximum permissible voltage for safe isolationmaximum permissible voltage for safe isolation
● in networks with grounded star point between
main and auxiliary circuit
400V
● in networks with grounded star point between
main and auxiliary circuit
400V
Protection class IP
Protection class IP
Protection class IP
Protection class IPProtection class IP
● on the front IP20
● of the terminal IP20
3RV2011-0HA10 Subject to change without notice
Page 1/
8
06/07/2019 © Copyright Siemens
Shock resistance
Shock resistance
Shock resistance
Shock resistanceShock resistance
● acc. to IEC 60068-2-27 25g / 11 ms
Mechanical service life (switching cycles)
Mechanical service life (switching cycles)
Mechanical service life (switching cycles)
Mechanical service life (switching cycles)Mechanical service life (switching cycles)
● of the main contacts typical 100000
● of auxiliary contacts typical 100000
Electrical endurance (switching cycles)
Electrical endurance (switching cycles)
Electrical endurance (switching cycles)
Electrical endurance (switching cycles)Electrical endurance (switching cycles)
● typical 100000
Certificate of suitability according to ATEX directive
2014/34/EU
DMT 02 ATEX F 001
Protection against electrical shock
Protection against electrical shock
Protection against electrical shock
Protection against electrical shockProtection against electrical shock finger-safe
Reference code acc. to DIN EN 81346-2
Reference code acc. to DIN EN 81346-2
Reference code acc. to DIN EN 81346-2
Reference code acc. to DIN EN 81346-2Reference code acc. to DIN EN 81346-2 Q
Ambient conditions
Installation altitude at height above sea level
Installation altitude at height above sea level
Installation altitude at height above sea level
Installation altitude at height above sea levelInstallation altitude at height above sea level
● maximum 2000m
Temperature compensation
Temperature compensation
Temperature compensation
Temperature compensationTemperature compensation -20...+60°C
Relative humidity during operation 10...95%
Main circuit
Number of poles for main current circuit
Number of poles for main current circuit
Number of poles for main current circuit
Number of poles for main current circuitNumber of poles for main current circuit 3
Adjustable pick-up value current of the current-
Adjustable pick-up value current of the current-
Adjustable pick-up value current of the current-
Adjustable pick-up value current of the current-Adjustable pick-up value current of the current-
dependent overload release
dependent overload release
dependent overload release
dependent overload releasedependent overload release
0.55...0.8A
Operating voltage
Operating voltage
Operating voltage
Operating voltageOperating voltage
● rated value 690V
● at AC-3 rated value maximum 690V
Operating frequency rated value
Operating frequency rated value
Operating frequency rated value
Operating frequency rated valueOperating frequency rated value 50...60Hz
Operating current rated value
Operating current rated value
Operating current rated value
Operating current rated valueOperating current rated value 0.8A
Operating current
Operating current
Operating current
Operating currentOperating current
● at AC-3
— at 400 V rated value 0.8A
Operating power
Operating power
Operating power
Operating powerOperating power
● at AC-3
— at 230 V rated value 120W
— at 400 V rated value 180W
— at 500 V rated value 250W
— at 690 V rated value 370W
Operating frequency
Operating frequency
Operating frequency
Operating frequencyOperating frequency
● at AC-3 maximum 151/h
Auxiliary circuit
Number of NC contacts for auxiliary contacts
Number of NC contacts for auxiliary contacts
Number of NC contacts for auxiliary contacts
Number of NC contacts for auxiliary contactsNumber of NC contacts for auxiliary contacts 0
Number of NO contacts for auxiliary contacts
Number of NO contacts for auxiliary contacts
Number of NO contacts for auxiliary contacts
Number of NO contacts for auxiliary contactsNumber of NO contacts for auxiliary contacts 0
Number of CO contacts
Number of CO contacts
Number of CO contacts
Number of CO contactsNumber of CO contacts
● for auxiliary contacts 0
3RV2011-0HA10 Subject to change without notice
Page 2/
8
06/07/2019 © Copyright Siemens
Protective and monitoring functions
Product function
Product function
Product function
Product functionProduct function
● Ground fault detection No
● Phase failure detection Yes
Trip class
Trip class
Trip class
Trip classTrip class CLASS 10
Design of the overload release
Design of the overload release
Design of the overload release
Design of the overload releaseDesign of the overload release thermal
Operational short-circuit current breaking capacity
Operational short-circuit current breaking capacity
Operational short-circuit current breaking capacity
Operational short-circuit current breaking capacityOperational short-circuit current breaking capacity
(Ics) at AC
(Ics) at AC
(Ics) at AC
(Ics) at AC(Ics) at AC
● at 240 V rated value 100kA
● at 400 V rated value 100kA
● at 500 V rated value 100kA
● at 690 V rated value 100kA
Maximum short-circuit current breaking capacity (Icu)
Maximum short-circuit current breaking capacity (Icu)
Maximum short-circuit current breaking capacity (Icu)
Maximum short-circuit current breaking capacity (Icu)Maximum short-circuit current breaking capacity (Icu)
● at AC at 240 V rated value 100kA
● at AC at 400 V rated value 100kA
● at AC at 500 V rated value 100kA
● at AC at 690 V rated value 100kA
Breaking capacity short-circuit current (Icn)
Breaking capacity short-circuit current (Icn)
Breaking capacity short-circuit current (Icn)
Breaking capacity short-circuit current (Icn)Breaking capacity short-circuit current (Icn)
● at 1 current path at DC at 150 V rated value 10kA
● with 2 current paths in series at DC at 300 V
rated value
10kA
● with 3 current paths in series at DC at 450 V
rated value
10kA
Response value current
Response value current
Response value current
Response value currentResponse value current
● of instantaneous short-circuit trip unit 10A
UL/CSA ratings
Full-load current (FLA) for three-phase AC motor
Full-load current (FLA) for three-phase AC motor
Full-load current (FLA) for three-phase AC motor
Full-load current (FLA) for three-phase AC motorFull-load current (FLA) for three-phase AC motor
● at 480 V rated value 0.8A
● at 600 V rated value 0.8A
Short-circuit protection
Product function Short circuit protection
Product function Short circuit protection
Product function Short circuit protection
Product function Short circuit protectionProduct function Short circuit protection Yes
Design of the short-circuit trip
Design of the short-circuit trip
Design of the short-circuit trip
Design of the short-circuit tripDesign of the short-circuit trip magnetic
Design of the fuse link for IT network for short-circuit
Design of the fuse link for IT network for short-circuit
Design of the fuse link for IT network for short-circuit
Design of the fuse link for IT network for short-circuitDesign of the fuse link for IT network for short-circuit
protection of the main circuit
protection of the main circuit
protection of the main circuit
protection of the main circuitprotection of the main circuit
● at 690 V gL/gG 6 A
Installation/ mounting/ dimensions
Mounting position
Mounting position
Mounting position
Mounting positionMounting position any
Mounting type
Mounting type
Mounting type
Mounting typeMounting type screw and snap-on mounting onto 35 mm standard mounting rail
according to DIN EN 60715
Height
Height
Height
HeightHeight 97mm
Width
Width
Width
WidthWidth 45mm
Depth
Depth
Depth
DepthDepth 97mm
3RV2011-0HA10 Subject to change without notice
Page 3/
8
06/07/2019 © Copyright Siemens
Produktspecifikationer
Varumärke: | Sirius |
Kategori: | Strömbrytare |
Modell: | 3RV2011-0HA10 |
Behöver du hjälp?
Om du behöver hjälp med Sirius 3RV2011-0HA10 ställ en fråga nedan och andra användare kommer att svara dig
Strömbrytare Sirius Manualer
6 September 2024
Strömbrytare Manualer
- Strömbrytare Cotech
- Strömbrytare Hager
- Strömbrytare Vimar
- Strömbrytare Uni-T
- Strömbrytare Klein Tools
Nyaste Strömbrytare Manualer
4 Oktober 2024
26 September 2024
20 September 2024
20 September 2024
17 September 2024
17 September 2024
16 September 2024
16 September 2024
16 September 2024
16 September 2024