SkyRC BD250 Bruksanvisning

Läs nedan 📖 manual på svenska för SkyRC BD250 (4 sidor) i kategorin Batteriladdare. Denna guide var användbar för 13 personer och betygsatt med 4.5 stjärnor i genomsnitt av 2 användare

Sida 1/4
1. Connect battery to BD250
INTRODUCTION
OPERATION
-1- -2-
INSTRUCTION MANUAL
SK-600133
BATTERY DISCHARGER & ANALYZER
FEATURES
It displays real time battery voltage, discharged capacity and discharge current.
It can test battery capacity that helps select batteries with desired capacity.
It saves time when user wishes to store their large capacity batteries.
It helps activate the best performance of your batteries for competition.
Thank you for choosing the SkyRC Battery Discharger & Analyzer (BD250). The BD250 is a powerful
discharging device that allows the user to discharge a battery at up to 35 amps or 250 watts and also
measures and compares the performance of batteries. BD250 allows for the precise measurement of battery
capacity and takes the guesswork out of choosing the best battery for your application.
The BD250 is much more than a simple battery discharger or a battery load tester. It will test virtually any
type or size of battery, any chemistry or number of cells, up to 35 volts.
The BD250 is ruggedly built and uses XT60 connector for battery connection. It is small with a high performance
cooling system. Digital LED indicates battery voltage, discharged capacity and discharge current.
2. Power ON
Press the dial once to
power ON the discharger,
the LED(V/mAh) will
blink with beep sound.
3. Select cut-off voltage and discharge current
By rotating the dial to change cut-off voltage, then press dial once to confirm.
By rotating the dial to change discharge current.
V / mAh V / mAh
A A
4. Start discharging process.
Press and hold dial for 2 seconds, the discharger will start with
beep sound.
During the discharging process, the digital LED(V/mAh) will
alternate the display of battery voltage and discharging capacity.
V / mAh V / mAh
6. Process finished.
When the discharging process has finished, the discharger will beep 5 times, and the LED(V/mAh)
will show battery voltage and discharge capacity respectively.
Digital LED(V/mAh)
Battery Voltage
/ Capacity Display
Digital LED(A)
Current Display
Rotary Dial
for Setting Cutoff Voltage
Discharging Current
Start Stop Button/
Temperature Controlled
Cooling Fan
XT60 Battery
Port
Data Link
Heat Sink
The LED(V/mAh) shows the current battery voltage.
Current Display Accuracy:
Voltage Display Accuracy:
Dimension:
Weight:
0.01-10.00A ±60mA
10.00-35.00A ±3%
5.4-10V ±80mV
10-20V ±120mV
20-35V ±160mV
136.6x104.8x107mm
879g
SPECIFICATION
Accepted Voltage Range: 5.40-35.00V
Low Voltage Alert: <5.2V
High Voltage Alert: >35V
Max. Discharge Power: 250W
Discharge Current Range: 0.01A-35.00A
Current Consumption in Sleep Mode: <100uA
Capacity Display Accuracy: 3%±
5. Stop discharging process.
A
During the discharging process, Press the dial once to stop the
discharging process, the digital LED(A) shows “Stop”.
NOTE:
After the discharge process completes, rotate the button to view the real-time battery voltage every
30 seconds for the first six minutes.
At certain intervals, the slower the voltage reduces during discharge, the better the battery
performances.
This feature can help to select good-performance battery for your race or flight.
If the discharger can't be powered on, the fuse
may be burnt.
You can replace the fuse by yourself and there
is one piece of replacement in the package. The specification is
40A/32V blade fuse.
HOW TO REPLACE THE FUSE
-3- -4-
WARRANTYAND SERVICE
We guarantee this product to be free of manufacturing and assembly defects for a period of one year from the time of purchase.
The warranty only applies to material or operational defects, which are present at the time of purchase. During that period, we will
repair or replace free of service charge for products deemed defective due to those causes.
This warranty is not valid for any damage or subsequent damage arising as a result of misuse, modification or as a result of failure to
observe the procedures outlined in this manual.
The warranty service is valid in China only.
If you need warranty service overseas, please contact your dealer in the first instance, who is responsible for processing
guarantee claims overseas. Due to high shipping cost, complicated custom clearance procedures to send back to China.
Please understand SkyRC can't provide warranty service to overseas end user directly.
If you have any questions which are not mentioned in the manual, please feel free to send email to info@skyrc.cn
Note:
1.
2.
3.
RoHS
Manufactured by
SKYRC TECHNOLOGY CO LTD  ., .
www skyrc com. . 7504-1290-01
LiPo
LiHV
NiMH
2S
3S
4S
5S
6S
7S
8S
2S
3S
4S
5S
6S
7S
8S
6S
7S
8S
9S
10S
11S
12S
13S
14S
15S
16S
17S
18S
19S
20S
6.0
9.0
12.0
15.0
18.0
21.0
24.0
6.2
9.3
12.4
15.5
18.6
21.7
24.8
5.4
6.3
7.2
8.1
9.0
9.9
10.8
11.7
12.6
13.5
14.4
15.3
16.2
17.1
18.0
8.40
12.60
16.80
21.00
25.20
29.40
33.60
8.70
13.05
17.40
21.75
26.10
30.45
34.80
9.00
10.50
12.00
13.50
15.00
16.50
18.00
19.50
21.00
22.50
24.00
25.50
27.00
28.50
30.00
35.00
27.77
20.83
16.66
13.88
11.90
10.41
35.00
26.88
20.16
16.12
13.44
11.52
10.08
35.00
35.00
34.72
30.86
27.77
25.25
23.14
21.36
19.84
18.51
17.36
16.33
15.43
14.61
13.88
29.76
19.84
14.88
11.90
9.92
8.50
7.44
28.73
19.15
14.36
11.49
9.57
8.21
7.18
27.77
23.80
20.83
18.51
16.66
15.15
13.88
12.82
11.90
11.11
10.41
9.80
9.25
8.77
8.33
When there is an error, digital LED will display the error code
ERROR MESSAGE
Input voltage is too high. This discharger accepts battery voltage from 5.4 to 35V,
if battery voltage is higher than 35V, it will stop working and show error message.
Over-temperature protection.
Input voltage is too low. This discharger accepts battery voltage from 5.4 to 35V,
if battery voltage is lower than 5.4V, it will stop working and show error message.
Min. Cut-off
Voltage
No. of
Cell
Battery
Type Voltage Min. Discharge Current (A)
Discharging power: 250W
Max. Discharge Current (A)
Discharging power: 250W
MAXIMUM DISCHARGE POWER CHART
OPTIONAL PARTS
LiPoPal (SK-500007)
The LiPoPal can check the voltage of each cell of a
lithium battery pack and remaining capacity in
percentage % during discharging process.
Improper usage may lead to fire, property damage and physical injury.
SAFETY NOTE
Never discharge a battery below its recommended cutoff voltage. Over-discharge may damage battery and cause
FIRE or EXPLOSION.
Never discharge a battery at a higher discharge rate than it is designed for.
Never leave the discharger unattended when it is connected to battery. If any malfunction is found,
TERMINATE THE PROCESS AT ONCE.
Place the discharger and battery on a non-flammable surface, and keep away from inflammables.
Never discharge swollen, leaky, or damaged batteries.
Batteries shall be discharged within a room temperature range of 10-40 .
Disconnect the battery and discharger once discharging has finished.
Recharge batteries immediately with an appropriate battery charger after discharge process is completed.
Some battery types do not like to remain discharged for extended periods of time.
PC SOFTWARE
PC software supplied with the BD250 is easy to use, intuitive. There
are two discharge mode: 1. Constant Power; 2. Constant Current.
The software can automatically sense battery cell count and
recommend a minimum safe discharge voltage. Discharge tests
may be viewed in Amp Hours, Watt Hours or Minutes. Results can
be graphed as Voltage vs. Amp hours, Watt hours, Minutes.
NOTE:
With PC software connected, BD250 allows you to export the battery voltage value at 30 seconds intervals
(for the first six minutes).

Produktspecifikationer

Varumärke: SkyRC
Kategori: Batteriladdare
Modell: BD250

Behöver du hjälp?

Om du behöver hjälp med SkyRC BD250 ställ en fråga nedan och andra användare kommer att svara dig




Batteriladdare SkyRC Manualer

Batteriladdare Manualer

Nyaste Batteriladdare Manualer