Revision B: 7.26.2014
P/N 20-26480
READ AND SAVE THESE INSTRUCTIONS
*Includes End Panels. ^With Levelers Extended 1 1/4” From Base Frame
MOBILE NON-REFRIGERATED SELF-SERVICE MERCHANDISER
> ROLL-DOWN SECURITY DOORS ARE OPTIONAL ON ALL UNITS
M O B I L E S E R I E S
INSTALLATION AND
OPERATING MANUAL
I:\Oper Manuals\Oasis\CO37_CO47_CO57_CO67_20-26480.pub
888 E. Porter Road · Muskegon, MI 49441 Phone: 231.798.8888 Fax: 231.798.4960 www.structuralconcepts.com
Model CO37 Shown With Optional
Roll-Down Security Door
Model CO57 Shown With Optional
Roll-Down Security Door
MODEL CO37…..…..….36 1/4”L* x 33 1/4”D x 81”H^
MODEL CO47……….....47 1/4”L* x 33 1/4”D x 81”H^
|||||
|||||
MODEL CO57……………......59 1/4”L* x 33 1/4”D x 81” H^
MODEL CO67……….…..…...71 1/4”L* x 33 1/4”D x 81”H^
2
TABLE OF CONTENTS
SHIPMENT CONDITION / DAMAGE DURING DELIVERY or UNCRATING / SHORTAGES …………
OVERVIEW / COMPLIANCE / WARNINGS / PRECAUTIONS / WIRING DIAGRAM / CORDS &
PLUGS .……..…………………………………………………………………………………………………..
CASE REMOVAL FROM SKID [CASTERS OR LEVELERS] …….……………...………………..………
POSITIONING & ALIGNING CASE / ADJUSTING LEVELERS / CASTERS / FRAME SUPPORT
RAILS .……………………………...…..….………………………...………………………………….………
ELECTRICAL SETUP / MERCHANDISER START-UP ……….……………………….…………..………
LIGHT FIXTURES [STANDARD vs. LED STYLE] …..……………………………………………………...
OPTIONAL ROLL DOWN SECURITY DOOR [SEE NEXT PAGE FOR EXTENDED DOOR] ………...
OPTIONAL ROLL DOWN SECURITY DOOR [SEE PREVIOUS PAGE FOR RETRACTED DOOR] ...
STIFFENER [FOR OPTIONAL ROLL DOWN SECURITY DOOR] & STIFFENER BRACKETS ……...
MAINTENANCE FUNDAMENTALS: BOLTING ADJOINED UNITS ……………………………………...
MAINTENANCE FUNDAMENTALS: SHELF ASSEMBLY / SHELVES / LIGHT FIXTURE …………….
MAINTENANCE FUNDAMENTALS: BALLAST ACCESS ……………………………………………….
SERIAL LABEL & LOCATION / TECHNICAL INFORMATION / ADDITIONAL INFORMATION ……....
CLEANING SCHEDULE / TROUBLESHOOTING …………………………………………………..……..
TECHNICAL SERVICE CONTACT INFORMATION & WARRANTY INFORMATION ………………….
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
3
SHIPMENT CONDITION / DAMAGE DISCOVERED DURING DELIVERY or UNCRATING / SHORTAGES
1.Shipment Condition
 Before and during unloading check all equipment for damage.
2.Damage Discovered During Delivery
 3rd Party Carrier: Describe damage on freight bill and obtain
signature of driver. Carrier will supply necessary claim forms.
If these steps are not taken, carrier may refuse your claim.
 Prepaid and Add: Contact carrier (and follow same procedure as
with 3rd party carrier). Also contact Structural Concepts at
1-800-433-9489.
3.Damage Discovered After Uncrating
 3rd Party Carrier: Contact carrier within 10 days of delivery for
their procures; retain all packaging. If these steps are not taken,
carrier may refuse your claim.
 Prepaid and Add: Contact carrier (and follow same procedure as
with 3rd party carrier). Also contact Structural Concepts at
1-800-433-9489 within 10 days of delivery.
4.Shortages
 If a shortage exists (and it is the responsibility of Structural
Concepts) call 1-800-433-9489. Structural Concepts will
acknowledge shortages within 10 days from receipt of
equipment.
 If a shortage involves the carrier, notify carrier immediately and
request an inspection.