ADDENDUM for the D22 MANUAL
Max Delay time
The D22 is now delivered with a max Delay time of
5200ms per channel. This applies for units with serial
numbers above 2000990 (see backpanel of unit).
If your unit has a serial number below 2000990 the max.
Delay time is either 1300ms or 2600ms.
For these units an upgrade-kit is available. Contact your
local dealer for more information.
This addendum cover changes to the manual revision 3.1.
Newest software is now 2.50.
The Complete manual including the changes below can be downloaded from www.tcelectronic.com
Frequently Asked Questions
Question: What parameters can be set using serial
remote control of the D22?
Answer: Preset change, Delay time and Bypass using an
RS485/422/232 controller.
Question: What serial protocol is used?
Answer: The serial protocol is 9600, N, 8, 1.
This means 9.6 kbaud, no parity, 8 bit, 1 stop.
Question: What is the command structure for the
remote protocol?
Answer: #AA,CMD,VALUE<CR>
AA is Unit Address number as set on the Utility page.
CMD is command. Commands could be:
PRE for preset change,
BYP for Bypass,
DEL for delay.
VALUE is (RAM) Preset number, 0 for Not Bypass,
1 for Bypass or amount of Delay.
<CR> is carriage return, the same as Enter or hex 0D.
Examples:
#05,PRE,10<CR> =Recall RAM preset no. 10 on D22
address 5.
#03,BYP,1<CR> =Bypass D22 address 3.
All commands and numbers are shown as ASCII.
Question: What is the data length of the delay time?
Answer: The delay is always a decimal number related to
the given delay unit of the D22. It is not possible to change
delay unit via the RS-485, so you must set this manually
before you send the command lines.
Example 1:
The delay unit is ms and you would like to set the delay to
10.5 ms:
#05,DEL,10.5<CR>
Example 2:
The delay unit is frames and you would like to set the delay
to 10.5 frames: #05,DEL,10.5<CR>
As you can see there is no difference between Example 1
and 2.
Example 3: The delay unit is ms and you would like to set
the delay to 10.5 frames:
You have to calculate the delay in ms yourself based on
the fps setting and then send a command-line.
Question: What ASCII characters should be sent for
Recall of RAM preset no. 10 on D22 address 5?
Answer: #05,PRE,10<CR> means these values (hex)
actually transmitted 23 30 35 2C 50 52 45 2C 31 30 0D
If you have questions left unanswered by the manual and
this addendum please refer to TC Support Interactive:
www.tcsupport.tc
TC Electronic, Sindalsvej 34, DK-8240 Risskov - tcdk@tcelectronic.com
D22 manual addendum
Rev 1 - SW - V 2.50
Prod. No. 608022311

Produktspecifikationer

Varumärke: TC Electronic
Kategori: Inte kategoriserad
Modell: D22

Behöver du hjälp?

Om du behöver hjälp med TC Electronic D22 ställ en fråga nedan och andra användare kommer att svara dig




Inte kategoriserad TC Electronic Manualer

Inte kategoriserad Manualer

Nyaste Inte kategoriserad Manualer