Telair TG 480 Bruksanvisning

Telair Generator TG 480

Läs nedan 📖 manual på svenska för Telair TG 480 (44 sidor) i kategorin Generator. Denna guide var användbar för 3 personer och betygsatt med 4.5 stjärnor i genomsnitt av 2 användare

Sida 1/44
Installation / Use / Maintenance Manual
Installation must be performed by skilled workshops
Vers. 4 8_2013
Eco Energy & Innovative Devices
• The “key” points for the installer are indicated by the symbol
• This handbook is to be delivered to the user client
• The installation procedure for models TG 480 and TG 600 is the same
• The “key” points for the User Client are indicated by using symbol
To get the best from your Eco Energy TG 480/600, we suggest you use service batteries
with > = 160 to 250 Ah overall capacity (e.g. No. 2 100 Ah parallel•connected batteries)
The present handbook describes the conditions of safety, installation, use and maintenance of the
“12V Eco Energy TG 480/600“
below called “Eco Energy TG 480/600”
Please read this handbook before starting installation, use or maintenance operations.
CONTENTS
1.Safety
For the Installer
3. Packaging content
5. Identification of components
8. Installation – Connection diagram
15. Testing
17. Installation – LPG gas system
For the User Client
24. Use of Eco Energy
27. Tips for proper use
28. Maintenance
29 Troubleshooting
31. Transport
31. Disposal
32. Technical Specifications and “CE Declaration of conformity”
34. Warranty
O
I
1
Safety
The Eco Energy TG 480/600 is safe and reliable in all its phases of work (transport, installation, use and
maintenance) on condition that the instructions given by this handbook are respected.
You must be aware of and have understood the handbook content before proceeding to even one phase of
installation or use.
Failing that can cause personal injuries, damages to the Eco Energy TG 480/600, to the connected fixtures or to the
vehicle on which it has been installed.
The Eco Energy TG 480/600 has been designed and manufactured for installation and use on motorhomes/caravans
(for recreational use only).
Anomalous operation or noise
In case of anomalous operation or noise: deactivate the Eco Energy and contact Telair s.r.l. (or authorised service
centres).
• The engine exhaust gas is toxic
The exhaust gas has always to be piped outwards .
Do not run the Eco Energy in closed or unsuitable environments (garages, ferry•boat holds, car transporters and any
other closed place): make sure that the Eco Energy is off (switch on control unit in 0 or OFF position, Eco Energy TG
480/600 knife•switch open or Eco Energy TG 480/600 gas tap closed).
• Cooling air and exhaust gas
Outlets for hot air (Eco Energy TG 480/600 cooling) and exhaust gas of Eco Energy TG 480/600 MUST NOT be
clogged or piped inside the motorhome. Exhaust gas and cooling air must not penetrate the living areas of the
motorhome.
• Cooling fan
Warning!! Open the electric knife•switch before removing the service cover.
By removing the service cover you can also access the cooling fan which can suddenly start running.
• Installation
The Eco Energy has to be installed outside the motorhome and, in any case, in open and ventilated environment.
Never install the Eco Energy in domestic environments (such as cellars, garages, or closed spaces of any kind).
The ground clearance of the Eco Energy must ensure safety also in reverse and when travelling on rough grounds,
humps and ramps!
Do not make electrical connections between the Eco Energy TG 480/600 and the 12V service system different from
those specified in this handbook, otherwise the Eco Energy TG 480/600, the connected fixtures or the vehicle on
which it has been installed could be damaged.
The Eco Energy TG 480/600 must be supplied with LPG gas pressure of 30 mbar. A 30 mbar (±2) pressure reducer
(normally provided on all motorhomes) must always be provided upstream of the Eco Energy. Never connect the Eco
Energy directly to the LPG gas tank or bottle.
• LPG gas is toxic, flammable and explosive
Do not smoke or use open flames in the vicinity of the bottle compartment or the Eco Energy as well as during the
installation and LPG gas refueling operations. LPG gas refueling must always be made in open spaces.
2

Produktspecifikationer

Varumärke: Telair
Kategori: Generator
Modell: TG 480

Behöver du hjälp?

Om du behöver hjälp med Telair TG 480 ställ en fråga nedan och andra användare kommer att svara dig




Generator Telair Manualer

Telair

Telair TG 480 Bruksanvisning

16 September 2024

Generator Manualer

Nyaste Generator Manualer