5020 0105- CO2 Monitor ( Temp. Operating Instructions CO2+ +RH)
Product Overview
Thank you for selecting -0105 desktop monitor, -0105 monitor is smart, compact and easy- -use. In addition to measuring 5020 CO25020 CO2to
the CO concentration, - can also measure the ambient temperature and the relative humidity25020 0105 (CO2 Temp. RH)+ + . This product is
developed to detect the presence of in ambient air and help people to take care of Indoor Air Quality. - can be widely used in the CO25020 0105
office building, school, exhibition hall, shopping mall, meeting room, fitness center, restaurant and other public places where personal comfort,
healthy is important.
Features:
,V Three different LED display shows the current Indoor Air Quality
,V Press MUTE button for alarm on/off.
,V Built in the LCD Backlight for easy reading in the dark.
Warnings:
,V Please take off the AC power adapter and store it well when this CO2 monitor left idle for
long.
,V This CO2 monitor is for home use, not suitable for certifying the test results.
,V If use this CO2 monitor for testing,5020-0105 does not guarantee the test results.
EMC/RFI
Readings may be affected if the unit is operated within radio frequency electromagnetic field strength of approximately 3 volts per meter, but the
performance of the instrument will not be permanently affected.
Note: Under the electromagnetic field of 3V/m, the reading will not meet the specification.
Warm-Up Time: 2 MIN.
Using the MUTE function:
Safety Instructions
Warning: Your safety is very important to us .To ensure to use the product correctly and safely, we would like to draw your attention to read the warning and
entire User Manual before using the product. These are important safety information and should be observed at all times.
1. Please handle the devices lightly, not subject the product to impact or shock. do
2. Do not immerse the product in water. Water can cause electric shock, fire or malfunction which may result in . damage
3. Do not keep the product under the hot and moisture environment. Keep the product away f m the heat source or near water. ro
4. Please use only the included power adaptor. Improper power adaptor or power sources can cause serious damage to the product, or result in injury or death
to the user.
Caring for product
To ensure you receive the maximum benefit from using this product, please observe the follow guidelines.
1. Cleaning Disconnect the power before clean. Use a damp cloth, do not use the liquid cleaning agent, such as benzene, thinner or aerosols.
2. Repair----Do not attempt to repair the product or modify the circuitry by yourself. Please contact with the local dealer or a qualified repairman if the product
1. Green LED Display (<800ppm)
2. Yellow LED Display (800-1200ppm)
3. Red LED Display ( >1200ppm ) & buzzer alarm
4 Mute Button .
5. Power Inlet
6. Housing Stand
7. Screw Position
1. 2 min. warm-up time when first time power.
2. The LCD shows 4 bars with 1sec blank cycle during warm- up
3. up The MUTE button is disabled during warm-
4. up The device shows the CO2 reading after warm-
Press MUTE button to select buzzer on/off. If the M function is off, while CO2 concentration exceed the alarm level (>1200 ppm), there will be a buzzer.“ UTE”
Note: The device setting with alarm is buzzer when power on first time, user can set the alarm on/off under MUTE function. on
needs servicing.
3. Air circulati ---The vents allow the air circulation liquid for measurement of the CO2 concentration and the ventilation should not be blocked. on
SPECIFICATIONS
Method - NDIR
Display - LCD Independent CO2, RH and Temperature readings
Sample Method - Diffusion or flow through (50 ~200 ml/min)
CO2 & Temperature Specification:
CO2 Specification:
Measurement Range
0-3,000 ppm display
Display Resolution
1 at 0~1,000ppm; at 1, 1 ,000ppm; 10ppm at 2, 1~ 000ppm ppm 5ppm 00 ~2 00 3,
Repeatability
±20 ppm @ 400ppm
Response Time
About 2min for 63% of step change
Warm-Up Time
2 min. at 22°C
Zone LED Display
Green: <800ppm; Yellow: 800~1200ppm;Red: >1200 ppm
Temperature Specification:
Temperature Range
0°C to 50°C display
Display Resolution
0.1°C
Display Unit
°C
Response Time
20-30 minutes (case must equalize with environment)
RH Specification:
n:
n:
n:n:
Measurement Range
20%-90% RH
Display Resolution
1%RH
Response time:
< min for 63% of step change 5
Operating Conditions:
Operating Temperature
0°C to 50°C
Humidity Ran ge
0 ~ 95% RH non-condensing
Storage Conditions:
Storage Temperature
-20°C to 60°C
Power Supply:
Power Supply
USB or 5 VDC from external AC/DC adapter which is included in package (Use specified AC adapter only)
DC Output voltage
5 VDC, 1000mA
AC Input voltage & Frequency
100 ~ 240 VAC, 0.2A 50 / 60 Hz
Dimension
Fault Codes & Troubleshooting Guide
Fault Icon
Description of the fault
Suggested Actions
The ambient temperature has exceeded the operating
temperature range 0°C to 50°C
This error will clear when the temperature returns the range between to
0°C to 50°C
EEPROM System Problem
Please reconnect AC adapter to 5020- CO2 Monitor. 0105
If the r5, Err6 s please contact the Service Department for “Er ” still appear ,
further assistance.