Tripp Lite SRQ24U Bruksanvisning

Läs nedan 📖 manual på svenska för Tripp Lite SRQ24U (28 sidor) i kategorin Server. Denna guide var användbar för 3 personer och betygsatt med 4.5 stjärnor i genomsnitt av 2 användare

Sida 1/28
SmartRack®
Quiet Rack Enclosure
with Sound Suppression
Models: SRQ18U, SRQ24U
Owner’s Manual
1111 W. 35th Street, Chicago, IL 60609 USA • www.tripplite.com/support
Copyright © 2018 Tripp Lite. All trademarks are the sole property of their respective owners.
Important Safety Instructions 2
Overview 2
Feature Identification 3
Enclosure Installation 4
Preparation 4
Unpacking 4
Placement 5
Ground Connection 6
Enclosure Configuration 6
Adjusting Mounting Rails 6
Equipment Installation 7
Installing or Removing Cage Nuts 7
Operation 8
Specifications 8
Storage and Service 8
Warranty and Product Registration 9
Español 10
Français 19
PROTECT YOUR INVESTMENT!
Register your product for quicker service and ultimate peace of mind.
You could also win an ISOBAR6ULTRA surge protector—a $100 value!
www.tripplite.com/warranty
2
Important Safety Instructions
SAVE THESE INSTRUCTIONS
All sections of this manual contain instructions and warnings that should be followed during the installation and use of the SmartRack Enclosures described in
this manual. Read all instructions and warnings thoroughly before attempting to move, install or use the SmartRack Enclosures described in this manual.
Failure to comply will create a risk of personal injury and property damage and may invalidate the warranty.
Keep the enclosure in a controlled indoor environment, away from moisture, temperature extremes, flammable liquids and gasses, conductive contaminants,
dust and direct sunlight.
Leave adequate space at the front and rear of the enclosure for proper access. Do not block, cover or insert objects into the external ventilation openings of
the enclosure.
The enclosure is extremely heavy. Use caution when handling the enclosure. Do not attempt to unpack, move or install it unassisted. Use a mechanical
device such as a forklift or pallet jack to move the enclosure in the shipping container.
Do not place any object on the enclosure, especially containers of liquid, and do not attempt to stack the enclosures.
Inspect the shipping container and the enclosure for shipping damage. Do not use the enclosure if it is damaged.
Leave the enclosure in the shipping container until it has been moved as close to the final installation location as possible. The casters are designed for
minor position adjustments within the final installation area only. The casters are not designed for moving the enclosure over longer distances.
Install the enclosure in a structurally sound area with a level floor that is able to bear the weight of the enclosure, all equipment that will be installed in the
enclosure and any other enclosures and/or equipment that will be installed nearby.
Do not push the enclosure from the side panels to move it. Pushing from the side panels will cause a tipping hazard.
When rolling the enclosure on its casters, always push it from behind, never pull it toward you.
A rolling enclosure can cause personal injury and property damage if not properly supervised. If rolling the enclosure down a ramp is required, use extreme
caution. Do not attempt to use ramps that have a slope steeper than 1:12.
Use caution when cutting packing materials. The enclosure could be scratched, causing damage not covered by the warranty.
Save all packing materials for later use. Repacking and shipping the enclosure without the original packing materials may cause product damage that will void
the warranty.
Do not re-ship the enclosure with additional equipment. The combined weight of the enclosure and installed equipment must not exceed the load capacity of
the pallet. Tripp Lite is not responsible for any damage that occurs during re-shipment.
Use of this equipment in life support applications where failure of this equipment can reasonably be expected to cause the failure of the life support
equipment or to significantly affect its safety or effectiveness is not recommended.
Overview
The SRQ18U/SRQ24U SmartRack Quiet Rack Cabinet with Sound Suppression uses foam sound-dampening panels built into its doors, side panels, and top and
bottom panels to reduce external acoustic levels caused by network equipment. A unique airflow design draws in cool air through its bottom panel intake,
passes it horizontally through the enclosure, and uses internal fans to push warm air out through two chambers located on its side panels. SRQ18U/SRQ24U
enclosures ship fully assembled for quick and easy deployment. All standard 19-inch rack-mount equipment is compatible with this unit.
Front Rear
3
Feature Identification
A Locking Front Doors with Foam Sound-Dampening Baffles
B Mounting Rails (Provide horizontal and vertical mounting points for equipment.)
C Cool-Air Intakes
D Side Panels with Foam Sound-Dampening Baffles
Note: Side panels are not removable.
E Locking Rear Doors with Foam Sound-Dampening Baffles
F Power Strip (for use with Exhaust Fans)
G Brush Strip Plate
H Exhaust Fans
I Hot Air Chambers
J Hot Air Exhaust Vents
K Casters
L Keys
Not Shown: Mounting hardware, documentation, shipping brackets and other shipping materials.
Front View
Rear View
A
B C
C
C
D
E
F
GH
I
J
K
K
K
K
L
H
D

Produktspecifikationer

Varumärke: Tripp Lite
Kategori: Server
Modell: SRQ24U

Behöver du hjälp?

Om du behöver hjälp med Tripp Lite SRQ24U ställ en fråga nedan och andra användare kommer att svara dig




Server Tripp Lite Manualer

Server Manualer

Nyaste Server Manualer