Q S GUICK TART UIDE
© 2012 Winland Electronics, Inc.
D-011-0099 Rev (0 /201 )F 7 5
ALWAYS TEST THE YSTEM S
Test the system to ensure proper operation prior to leaving the job site To test the system, either change the probe’s .
temperature so it exceeds your limits, or change the limits to simulate an alarm. If a delay has been programmed, take the
delay out, test the unit, and then put the delay back in.
FREEZER OOLER ONITORING/C M
Never install the EnviroAlert console in a cooler or freezer (condensing environment). Instead, use a remote probe (TEMP-L-S
or TEMP-L-W) and program your zone accordingly. Extend the length of probe wiring up to 1,000’ (304.8m) using 22-18 AWG
twisted pair.
AVOIDING ALSE LARMS ON A F A COOLER OR REEZER F
Both the EA200 and EA400 offer an alarm delay from 0-120 minutes for each zone When a cooler or freezer door is opened, .
the temperature will rise and the probe will detect that rise. Freezers periodically need to enter a defrost cycle which may
also cause the temperature to rise above your limits. Set delays to avoid nuisance alarms under these normal circumstances.
We cannot advise you on what to set for delays or limits.
O -BN OARD TEMP ENSOR ONLY S (EA200 )
The EA200 has an on-board ambient temperature sensor and it is programmed on Zone 1.
More information and product manuals can be found at: www.winland.com
Tech Support 8:00am - 5:00pm Central Time
(800) 635-4269 • +1-507-625-7231 P
www.winland.com
STEP 1: CONNECT POWER AND PROBE(S)
Connect power to the PWR IN terminals, as shown in Figure 1. Be sure to observe proper polarity. Connect the probe(s) to the
zone(s) you intend to monitor. Extend the length of probe wiring up to 1,000’ (304.8m) using 22-18 AWG twisted pair.
EA200 NOTE: Zone 1 is dedicated for the on-board temperature sensor. Remote probes must be programmed on Zone 2.
There is only one input for a remote probe on the EA200 - this is Zone 2.
EA400 NOTE: The EA400 does not have an on-board temperature sensor and uses only remote probes.
STEP 2: UNLOCK CONSOLE FOR PROGRAMMING
To unlock the console, press and simultaneously release the ENTER and ALARM SILENCE buttons. The
“lock” icon should change to “unlocked”.
STEP 3: SET THE TIME AND DATE
Press the TIME/DATE button. Using either the INCREASE or DECREASE button, adjust the hours and then press the ENTER
button. Continue in this manner to set the minutes, AM/PM, year, month, and day. If power is lost, the time and date must
be reset.
STEP 4: PROGRAM THE ZONE(S)
1. Press the ZONE button. The active zone number will be flashing.
2. Select the zone you wish to program using INCREASE or DECREASE and then press ENTER. The “no”
means “not operational” and indicates the zone is currently off. Any zone not programmed should
be set to “no” and therefore turned off.
3. Based on the chart (Figure 2), select the proper sensor type using INCREASE or DECREASE and press ENTER.
Figure 1 - EA200 and EA400 Wiring
POWER REQUIREMENTS:
EA200-12: 11 to 14 VDC @ 120mA 11 to 14 VDC @ 200mAEA400-12:
EA200-24: 23 to 26 VDC @ 120mA 23 to 26 VDC @ 200mAEA400-24:
AUX OUT
Zone 1
PWR IN
PWR OUT
Z one 2
REMOTE PROBE INPUT
ALARM OUTPUTS
(On-Board
Sensor)
Zone 2
(External
Probe)
EA200
AUX OUT
Zone 1
Z one 2
Z one 3
Z one 4
PWR IN
PWR OUT
Z one 1
Zone 2
Zone 3
Z one 4
REMOTE PROBE INPUTS
ALARM OUTPUTS
EA400
Lock Unlock
4. Continue in this manner to set the
• high limit
• low limit
• optional time delay in minutes (this defaults to 0)
• non-alarm relay state (ENERGIZE/DE-ENERGIZE)
NOTE: If you are powering this device
from a system with battery back-up,
DE-ENGERGIZE (the default) generally
makes the most sense. If an alarm
is desired upon loss of power to the
EnviroAlert, select ENERGIZE. However,
the normally-open (N.O.) and normally-
closed (N.C.) contacts shown in Figure 1
will then be functionally opposite.
STEP 5: ALARM WIRING
You have the option of using the AUX
relay for all-in-one notification or using
the individual relay outputs. The AUX relay will change state when any zone is in alarm and can be cancelled for 10 minutes
using the ALARM SILENCE button. The individual outputs are not affected by the ALARM SILENCE button.
NOTE: If you are using the individual relay outputs, Output 1 corresponds to Zone 1; Output 2 corresponds to Zone 2; etc.
See Figure 1.
STEP 6: TEST THE SYSTEM
Test the system to ensure proper operation prior to leaving the job site. To test the system, either change the probe’s
temperature so it exceeds your limits, or change the limits to simulate an alarm. If a delay has been programmed, take the
delay out, test the unit, and then put the delay back in.
ADDITIONAL FEATURES
OFFSET button: The EnviroAlert has the ability to adjust the displayed temperature reading for each zone to match to
a known-good reference (±9 degrees). To use this feature, press the OFFSET button, choose which zone you wish to offset,
press ENTER, adjust the value of the offset, and then press ENTER again.
ALARM HISTORY button: This will display the most recent eight alarm events. The display will toggle between
the time and date. To scroll through the alarm events, use the INCREASE or DECREASE buttons. Press the ALARM HISTORY
button again to exit. This feature relies on the time and date being set correctly. To clear the alarm history, press and hold the
ALARM HISTORY button until you see “CLr”.
Probe Type Description
°C or °F Legacy (discontinued) polarity-sensitive temperature probes
1106, 1107, 1108, 1109, 1109A
Red °C or
Red °F
TEMP-H-S (32° to 300° F) and TEMP-H-W (32° to 221° F)
High-temperature range thermistor probes
Blue °C or
Blue °F
TEMP-L-S (-58° to 158° F) and TEMP-L-W (-58° to 158° F)
Low-temperature range thermistor probes
HA-III+ Humidity probe (5 to 95 % RH)
W-S-S and W-UC-S
Water detection probe (surface and under-carpet) supervised
Figure 2 - Remote Probe Selections
To insure proper operation, test weekly.
Produktspecifikationer
Varumärke: | Winland |
Kategori: | Smarth hem |
Modell: | EnviroAlert EA-400 |
Behöver du hjälp?
Om du behöver hjälp med Winland EnviroAlert EA-400 ställ en fråga nedan och andra användare kommer att svara dig
Smarth hem Winland Manualer
25 September 2024
Smarth hem Manualer
- Smarth hem Bosch
- Smarth hem IKEA
- Smarth hem Philips
- Smarth hem Panasonic
- Smarth hem Gigaset
- Smarth hem Honeywell
- Smarth hem Abus
- Smarth hem Acer
- Smarth hem Ajax
- Smarth hem Alecto
- Smarth hem Aluratek
- Smarth hem Brennenstuhl
- Smarth hem Hikvision
- Smarth hem Nedis
- Smarth hem Livoo
- Smarth hem Manta
- Smarth hem Asus
- Smarth hem Renkforce
- Smarth hem Blaupunkt
- Smarth hem TP Link
- Smarth hem Lenovo
- Smarth hem Ezviz
- Smarth hem Trust
- Smarth hem Elro
- Smarth hem EMOS
- Smarth hem KlikaanKlikuit
- Smarth hem KKT Kolbe
- Smarth hem Denver
- Smarth hem Imou
- Smarth hem Hama
- Smarth hem Byron
- Smarth hem Smartwares
- Smarth hem Profile
- Smarth hem Salus
- Smarth hem Eufy
- Smarth hem Burg-Wachter
- Smarth hem Linksys
- Smarth hem Sanus
- Smarth hem Netgear
- Smarth hem LevelOne
- Smarth hem DIO
- Smarth hem Laica
- Smarth hem Hive
- Smarth hem Netatmo
- Smarth hem NGS
- Smarth hem FireAngel
- Smarth hem Chacon
- Smarth hem Reolink
- Smarth hem Tesla
- Smarth hem Rademacher
- Smarth hem Busch-Jaeger
- Smarth hem D-Link
- Smarth hem Logicom
- Smarth hem Tenda
- Smarth hem Vivax
- Smarth hem Niko
- Smarth hem Gira
- Smarth hem Jung
- Smarth hem Ring
- Smarth hem Nobo
- Smarth hem Fibaro
- Smarth hem Easy Home
- Smarth hem Qnect
- Smarth hem EQ3
- Smarth hem Homematic IP
- Smarth hem Home Easy
- Smarth hem X-Sense
- Smarth hem SPC
- Smarth hem Crestron
- Smarth hem Chuango
- Smarth hem ETiger
- Smarth hem Drayton
- Smarth hem Aqara
- Smarth hem Ferguson
- Smarth hem KanexPro
- Smarth hem Shelly
- Smarth hem Paulmann
- Smarth hem Kogan
- Smarth hem Intertechno
- Smarth hem V-Tac
- Smarth hem EQ-3
- Smarth hem Schellenberg
- Smarth hem EVOLVEO
- Smarth hem Gossen Metrawatt
- Smarth hem Brilliant
- Smarth hem Tellur
- Smarth hem TELE System
- Smarth hem Airthings
- Smarth hem SwitchBot
- Smarth hem Mach Power
- Smarth hem Sonoff
- Smarth hem Blebox
- Smarth hem Lutron
- Smarth hem Meross
- Smarth hem Origin Acoustics
Nyaste Smarth hem Manualer
27 Oktober 2024
21 Oktober 2024
18 Oktober 2024
14 Oktober 2024
9 Oktober 2024
6 Oktober 2024
3 Oktober 2024
2 Oktober 2024
2 Oktober 2024
2 Oktober 2024