Worcester-Bosch GB162 Bruksanvisning

Läs nedan 📖 manual på svenska för Worcester-Bosch GB162 (12 sidor) i kategorin Panna. Denna guide var användbar för 3 personer och betygsatt med 4.5 stjärnor i genomsnitt av 2 användare

Sida 1/12
UK/IE
Operating Instructions
Wall hung gas fired condensing boiler
Worcester Commercial Boiler Series
GB162-50/65/85/100 V2
6720814332-0.1TD
For central heating systems and indirect fed domestic hot water
6720814333 (2018/04) UK/IE
If you smell gas:
Well away from the building: In Great Britain call the National
Gas Emergency Service on 0800 111 999.
In Northern Ireland call 0800 002 001 and in Ireland call
1850 20 50 50
L.P.G. boilers: Call the suppliers number on the side of the
gas tank.
These appliances are for use with Natural Gas or L.P.G.
(Cat. II2H3P type C13, C33 & C53)
Model GC Number
Natural Gas 50 kW 41-406-66
65 kW 41-406-67
Key to symbols and safety instructions
6720814333 (2018/04)2
Table of Contents
1 Key to symbols and safety instructions . . . . . . . . . . . . . . . . . . . 2
1.1 Key to symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
1.2 General safety instructions . . . . . . . . . . . . . . . . . . . . . . . . 2
2 Product information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
2.1 Declaration of Conformity . . . . . . . . . . . . . . . . . . . . . . . . 3
2.2 Appliance types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
2.3 Energy efficiency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
3 Operating the boiler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
3.1 Overview of components . . . . . . . . . . . . . . . . . . . . . . . . . 5
3.2 Opening the gas isolation valve . . . . . . . . . . . . . . . . . . . . 5
3.3 Opening service valves . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
3.4 Switch on the boiler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
3.5 Check water pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
3.6 Setting the maximum boiler temperature . . . . . . . . . . . . 5
3.7 Heating controller settings . . . . . . . . . . . . . . . . . . . . . . . . 5
4 Operating the appliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
4.1 Information menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
4.2 Setup menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
4.3 Anti-Freeze Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
4.4 Key lock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
5 Inspection and servicing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
5.1 Refilling the heating system . . . . . . . . . . . . . . . . . . . . . . . 8
5.2 Cleaning the casing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
6 Shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
6.1 Standard shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
6.2 Shutting down when there is a risk of frost . . . . . . . . . . . 8
7 Display information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
7.1 Display codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
7.2 A fault has occurred but no fault code is displayed . . . . . 9
8 Energy saving and environmental protection . . . . . . . . . . . . . . 9
8.1 Energy savings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
8.2 Environment / disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
1 Key to symbols and safety instructions
1.1 Key to symbols
Warnings
The following keywords are defined and can be used in this document:
NOTICE indicates a situation that could result in damage to property
or equipment.
CAUTION indicates a situation that could result in minor to medium
injury.
WARNING indicates a situation that could result in severe injury or
death.
DANGER indicates a situation that will result in severe injury or
death.
Important information
Additional symbols
1.2 General safety instructions
Instructions for the target group
These operating instructions are intended for the heating system user.
All instructions must be observed. Failure to comply with instructions
may result in material damage and personal injury, including possible
loss of life.
Read and retain the operating instructions (heat source, heating
controller, etc.) prior to operation.
Observe safety instructions and warnings.
If you smell gas
A gas leak could potentially cause an explosion. If you smell gas, observe
the following rules.
Avoid producing flames or sparks:
Do not smoke, do not use a lighter or strike matches.
Do not operate any electrical switches or unplug any equipment.
Do not use the telephone or ring doorbells.
Turn off the gas supply at the main shut-off valve or at the gas meter.
Open windows and doors.
Warn your neighbours and leave the building.
Prevent anyone from entering the building.
Stay well away from the building: call the emergency services and the
gas supplier.
Warnings in this document are identified by a warning
triangle printed against a grey background.
Keywords at the start of a warning indicate the type and
seriousness of the ensuing risk if measures to prevent
the risk are not taken.
This symbol indicates important information where
there is no risk to people or property.
Symbol Explanation
Step in an action sequence
Cross-reference to another part of the document
List entry
List entry (second level)
Table 1
Product information
6720814333 (2018/04) 3
Correct use
The wall hung gas fired condensing boiler may only be used in sealed
heating systems for central heating and Domestic Hot Water.
Any other use is not permitted. We assume no responsibility for damage
caused by incorrect use.
Inspection and servicing
If there is a lack of cleaning, inspection or maintenance, or if these are
carried out incorrectly, this may result in material damage and/or
personal injury, including possible loss of life.
Have work carried out only by an approved installer.
Have any defects rectified immediately.
Have the heating system inspected once a year by an approved Gas
Safe registered contractor, and have any required maintenance or
cleaning work carried out.
We recommend that you enter into a contract covering an annual
inspection and needs-based maintenance with an approved
contractor.
Conversion and repairs
Modifications to the heat source or other parts of the heating system can
result in personal injury and/or material damage.
Have work carried out by an approved Gas Safe contractor only.
Never remove the casing of the heat source.
Never carry out any modifications to the heat source or to other parts
of the heating system.
Never close, block or obstruct the outlet of the pressure relief valves.
Heating systems with DHW cylinder: During heat-up, water can
escape from the pressure relief valve of the DHW cylinder.
Open flue operation
The installation location must be adequately ventilated, if the heat
source draws its combustion air from the room.
Never cover or reduce the size of ventilation apertures in doors,
windows and walls.
Consult a contractor to ensure that ventilation requirements are met:
if structural modifications are made (e.g. replacing windows and
doors)
if appliances with an air discharge outside are subsequently
installed (e.g. extractor fans, kitchen fans or air conditioning
units).
Condensate pipe work
Condensate is produced in this boiler and removed via a condensate
pipe to a drain. Modification or blocking of the condensate pipe work is
not permitted.
Combustion air/ambient air
The air in the installation room must be free of combustible or chemically
aggressive substances.
Do not use or store combustible or explosive materials (paper,
propellants, thinners, paints, etc.) within the vicinity of the
appliance.
Do not use or store corrosive substances (solvents, adhesives,
chlorinated cleaning agents, etc.) within the vicinity of the appliance.
Appliance operation
This appliance can be used by children aged from 8 years and above and
persons with reduced physical, sensory or mental capabilities or lack of
experience and knowledge, if they have been given supervision or
instruction concerning the use of the appliance, in a safe way, and
understand the hazards involved.
Children shall not play with the appliance.
Cleaning and user maintenance shall not be made by children without
supervision.
2 Product information
2.1 Declaration of Conformity
2.2 Appliance types
This document refers to the following appliance types:
GB162-50 V2
GB162-65 V2
GB162-85 V2
GB162-100 V2
The designation of the boiler comprises the following:
Worcester: manufacturer
GB162 V2: product name
50, 65, 85 or 100: type name (output)
The design and operating characteristics of this product
comply with the European and national requirements.
The CE marking declares that the product complies with
all the applicable EU legislation, which is stipulated by
attaching this marking.
The complete text of the Declaration of Conformity is
available on the Internet (à address on the back cover of
these instructions).

Produktspecifikationer

Varumärke: Worcester-Bosch
Kategori: Panna
Modell: GB162

Behöver du hjälp?

Om du behöver hjälp med Worcester-Bosch GB162 ställ en fråga nedan och andra användare kommer att svara dig




Panna Worcester-Bosch Manualer

Panna Manualer

Nyaste Panna Manualer