Worcester Greenstar 440CDi Highflow Bruksanvisning
Worcester
Pannor & pannor
Greenstar 440CDi Highflow
Läs nedan 📖 manual på svenska för Worcester Greenstar 440CDi Highflow (20 sidor) i kategorin Pannor & pannor. Denna guide var användbar för 8 personer och betygsatt med 4.5 stjärnor i genomsnitt av 2 användare
Sida 1/20
UK/IE
USER INSTRUCTIONS
FLOOR STANDING RSF GAS FIRED CONDENSING COMBINATION BOILER
GREENSTAR HIGHFLOW 440CDi & 550CDi
6720648665-00.1Wo
FOR SEALED CENTRAL HEATING SYSTEMS AND MAINS FED DOMESTIC HOT WATER
6 720 815 063 (2015/05)
The appliances are for use with:
Natural Gas or L.P.G. (Cat. II 2H3P type C13, C33 & C53)
Natural Gas:
440CDi ErP, GC number 47-406-85
550CDi ErP, GC number 47-406-87
L.P.G.:
440CDi ErP, GC number 47-406-86
550CDi ErP, GC number 47-406-88
ErP ErP
2
preface
GREENSTAR HIGHFLOW CDi ErP– 6 720 815 063 (2015/05)
PREFACE
PLEASE READ THESE INSTRUCTIONS CAREFULLY
These instructions are applicable to the Worcester, Bosch
Group boiler model stated on the front cover only.
These instructions apply in the UK/IE only and must be followed
except for any statutory obligation.
After installation please leave this User instruction Manual,
Installation, Commissioning and Servicing Instructions and
completed Benchmark Checklist with the user.
DEDICATED TO HEATING COMFORT
Thank you for purchasing a Greenstar gas-fired condensing
combination boiler manufactured by Worcester, Bosch Group.
The company prides itself on manufacturing boilers to the
strictest quality control standards throughout every stage of
production.
Worcester, Bosch group has led the field in innovative boiler
design and performance for 50 years. This heritage means all
our products are of exceptional quality and proven reliability.
The Greenstar range in particular is extremely energy efficient,
offering you economical running costs and value for money. It
sits in SEDBUK 2005 Band A, scoring highly in SEDBUK 2009,
and is therefore amongst the top energy rated boilers available.
There is also the reassurance of our no-nonsense 2 years parts
and labour guarantee - backed up by Worcester Total Cover, an
optional complete maintenance scheme to keep your boiler
operating at peak condition and efficiency.
CONTENTS
1 Symbols and safety precautions . . . . . . . . . 3
1.1 Explanation of symbols . . . . . . . . . . . 3
1.2 safety precautions . . . . . . . . . . . . . . . 3
2 Product details . . . . . . . . . . . . . . . . . . . . . . . . 4
2.1 General Information . . . . . . . . . . . . . . 4
2.2 Product data on energy consumption 4
3 Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
3.1 Switching the boiler ON/OFF . . . . . . . 6
3.1.1 Switching ON . . . . . . . . . . . . . . . . . . . 6
3.2 Setting the central heating temperature
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
3.2.1 Controlling the central heating . . . . . 6
3.3 Frost protection (for the boiler) . . . . 7
3.3.1 Frost protection (for the heating
system) . . . . . . . . . . . . . . . . . . . . . . . . 7
3.4 Setting the domestic hot water
temperature . . . . . . . . . . . . . . . . . . . . 7
3.5 ECO indicator . . . . . . . . . . . . . . . . . . . 8
3.6 Fault condition . . . . . . . . . . . . . . . . . . 9
4 System Pressure . . . . . . . . . . . . . . . . . . . . . . . 9
4.1 Sealed heating systems . . . . . . . . . . . 9
4.2 Locating the integral filling link . . . . 10
5 Clearances . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
6 Maintaining your Boiler . . . . . . . . . . . . . . . . 12
7 Fault Finding . . . . . . . . . . . . . . . . . . . . . . . . . 13
7.1 Error codes . . . . . . . . . . . . . . . . . . . . 14
7.2 Extreme cold weather . . . . . . . . . . . 15
8 Fault or Breakdown . . . . . . . . . . . . . . . . . . . 16
9 Tips on energy saving . . . . . . . . . . . . . . . . . . 17
10 Environment / disposal . . . . . . . . . . . . . . . . 18
11 Your guarantee . . . . . . . . . . . . . . . . . . . . . . . 18
12 Glossary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
3
Symbols and safety precautions
GREENSTAR HIGHFLOW CDi ErP – 6 720 815 063 (2015/05)
1 SYMBOLS AND SAFETY PRECAUTIONS
1.1 EXPLANATION OF SYMBOLS
WARNING SYMBOLS
Signal words indicate the seriousness of the hazard in terms of
the consequences of not following the safety instructions.
• indicates possible damage to property or NOTICE
equipment, but where there is no risk of personal injury.
• indicates possible personal injury.CAUTION
• indicates possible severe personal injury.WARNING
IMPORTANT INFORMATION
ADDITIONAL SYMBOLS
1.2 SAFETY PRECAUTIONS
IF YOU SMELL GAS
A gas leak could potentially cause an explosion. If you smell gas,
observe the following rules.
▶ Prevent flames or sparks:
– Do not smoke, use a lighter or strike matches.
– Do not operate any electrical switches or unplug any
equipment.
– Do not use the telephone or ring doorbells.
▶ Turn off the gas at the meter or regulator.
▶ Open windows and doors.
▶ Warn your neighbours and leave the building.
▶ Prevent anyone from entering the building.
▶ Well away from the building: call the National Gas
Emergency Service on 0800 111 999.
▶ L.P.G. boilers: Call the supplier’s number on the side of the
gas tank.
BOILER OPERATION:
This boiler must only be operated by a responsible adult who
has been instructed in, understands and is aware of the boiler's
operating conditions and effects.
COMBUSTIBLE AND CORROSIVE MATERIALS:
Chemically aggressive substances can corrode the boiler and
invalidate any guarantee.
• Do not store or use any combustible materials (paper,
thinners, paints, propellants, cleaning agents etc.) inside
the cupboard containing the boiler or within the vicinity of
the appliance.
FITTINGS AND MODIFICATIONS:
Only a competent engineer can remove the boiler case and
carry out any work, in accordance with the Gas Safety
(Installation and Use) Regulations.
• Do not remove the boiler case.
Any misuse or unauthorised modifications to the boiler, flue or
associated accessories and heating system will invalidate the
guarantee.
• Do not modify the boiler or flue system in any way.
Worcester, Bosch Group accepts no liability arising from any
such actions. This does not affect your statutory rights.
CLEANING THE BOILER CASE:
Use a damp, soft cloth to clean the outer painted metal case of
the boiler, do not use chemicals or abrasive materials.
Safety instructions in this document are
framed and identified by a
warning triangle which is printed on a grey
background.
Notes contain important information in
cases where there is no risk of
personal injury or material losses and are
identified by the symbol shown on the left.
They are bordered by horizontal lines above
and below the text.
Symbol Meaning
1. a numbered step in an action sequence
▶ a step in an action sequence
a reference number to identify or refer to a part or
item
• a list entry
– a list entry (second level)
1
Produktspecifikationer
Varumärke: | Worcester |
Kategori: | Pannor & pannor |
Modell: | Greenstar 440CDi Highflow |
Enhetsplacering: | Semi-ingebouwd |
Inbyggd display: | Ja |
Vikt: | 36000 g |
Bredd: | 600 mm |
Djup: | 550 mm |
Höjd: | 815 mm |
Nettoskatt: | 2400 W |
Antal platsinställningar: | 14 couverts |
Dörrfärg: | Niet van toepassing |
Sladdlängd: | 1.75 m |
Torkningsklass: | A |
Cykelns längd: | - min |
Ljudnivå: | 44 dB |
Årlig-energiförbrukning: | 266 kWu |
Förpackningens vikt: | 39000 g |
Energieffektivitetsklass (gammal): | A++ |
Installationsfackets bredd: | 600 mm |
Installationsfack djup: | 550 mm |
Vattenförbrukning per cykel: | 9.5 l |
Nuvarande: | 10 A |
Installationsfack höjd (min): | 815 mm |
Justerbara fötter: | Ja |
Djup när dörren är öppen: | 1150 mm |
Produktstorlek: | Volledige grootte (60 cm) |
Färgkontrollpanel: | Roestvrijstaal |
Tvättprogram: | Eco |
Energiförbrukning per cykel: | 0.93 kWu |
Årlig vattenförbrukning: | 2660 l |
Avloppsslangens längd: | 1.9 m |
Vattentillförselslangens längd: | 1.65 m |
Installationsfack höjd (max): | 875 mm |
Strömförbrukning (när avstängd): | 0.1 W |
AC-ingångsspänning: | 220 - 240 V |
AC-ingångsfrekvens: | 50 - 60 Hz |
Behöver du hjälp?
Om du behöver hjälp med Worcester Greenstar 440CDi Highflow ställ en fråga nedan och andra användare kommer att svara dig
Pannor & pannor Worcester Manualer
3 Oktober 2024
30 September 2024
18 September 2024
15 Augusti 2024
31 Juli 2024
30 Juli 2024
25 Juli 2024
25 Juli 2024
Pannor & pannor Manualer
- Pannor & pannor Electrolux
- Pannor & pannor ATAG
- Pannor & pannor Bosch
- Pannor & pannor AEG
- Pannor & pannor Philips
- Pannor & pannor Panasonic
- Pannor & pannor BEKO
- Pannor & pannor Inventum
- Pannor & pannor Junkers
- Pannor & pannor Nefit
- Pannor & pannor Remeha
- Pannor & pannor Siemens
- Pannor & pannor Whirlpool
- Pannor & pannor Vaillant
- Pannor & pannor ACV
- Pannor & pannor GE
- Pannor & pannor Orbegozo
- Pannor & pannor Fagor
- Pannor & pannor Gorenje
- Pannor & pannor Hitachi
- Pannor & pannor Teka
- Pannor & pannor Hisense
- Pannor & pannor Vox
- Pannor & pannor Hotpoint
- Pannor & pannor Sencor
- Pannor & pannor Midea
- Pannor & pannor De Dietrich
- Pannor & pannor Solac
- Pannor & pannor Svan
- Pannor & pannor Daikin
- Pannor & pannor Intergas
- Pannor & pannor Stiebel Eltron
- Pannor & pannor Buderus
- Pannor & pannor Dometic
- Pannor & pannor Elco
- Pannor & pannor Dimplex
- Pannor & pannor Masterwatt
- Pannor & pannor Nibe
- Pannor & pannor Ferroli
- Pannor & pannor Haier
- Pannor & pannor Ariston Thermo
- Pannor & pannor Elba
- Pannor & pannor Corberó
- Pannor & pannor Kelvinator
- Pannor & pannor Mora
- Pannor & pannor Buffalo
- Pannor & pannor Viessmann
- Pannor & pannor Franke
- Pannor & pannor Camry
- Pannor & pannor Jocel
- Pannor & pannor Atlantic
- Pannor & pannor Technika
- Pannor & pannor Plieger
- Pannor & pannor Bulex
- Pannor & pannor Tesy
- Pannor & pannor Waeco
- Pannor & pannor AWB
- Pannor & pannor HTW
- Pannor & pannor Quooker
- Pannor & pannor Edilkamin
- Pannor & pannor OSO
- Pannor & pannor Kunft
- Pannor & pannor Clage
- Pannor & pannor Noveen
- Pannor & pannor Joven
- Pannor & pannor Daalderop
- Pannor & pannor Cointra
- Pannor & pannor Baxi
- Pannor & pannor Rommer
- Pannor & pannor Biasi
- Pannor & pannor Quantum
- Pannor & pannor Morco
- Pannor & pannor Thermor
- Pannor & pannor Khind
- Pannor & pannor SolarEdge
- Pannor & pannor LERAN
- Pannor & pannor Ygnis
- Pannor & pannor Intellihot
- Pannor & pannor Airthereal
- Pannor & pannor Thermoflow
- Pannor & pannor Apricus
- Pannor & pannor Rinnai
- Pannor & pannor Sime
- Pannor & pannor Kospel
- Pannor & pannor Neopower
- Pannor & pannor Gleamous
- Pannor & pannor AquaMAX
- Pannor & pannor My-PV
- Pannor & pannor EvoHeat
- Pannor & pannor Rheem
- Pannor & pannor Mission Air
- Pannor & pannor Solahart
- Pannor & pannor ENEFT
- Pannor & pannor AquaTech
- Pannor & pannor Imarflex
- Pannor & pannor MicroHeat
- Pannor & pannor Noritz
Nyaste Pannor & pannor Manualer
26 Oktober 2024
23 Oktober 2024
23 Oktober 2024
22 Oktober 2024
22 Oktober 2024
22 Oktober 2024
22 Oktober 2024
22 Oktober 2024
22 Oktober 2024
22 Oktober 2024