Zodiac Z200 Bruksanvisning

Läs nedan 📖 manual på svenska för Zodiac Z200 (12 sidor) i kategorin Värmare. Denna guide var användbar för 10 personer och betygsatt med 4.5 stjärnor i genomsnitt av 2 användare

Sida 1/12
Instrucons for installaon
2
Read this noce carefully before installing, maintaining or repairing this appliance!
The symbol indicates important informaon that you must take into account to avoid the risk of
damage to persons or the appliance.
The symbol indicates useful informaon as an indicaon.
Warning
As part of a connuous improvement process our products may be modied without prior noce.
Exclusive use: the heang of pool water (must not be used for any other purpose),
The appliance must be installed by a qualied technician, in compliance with the manufacturers instrucons
and in compliance with current local standards. The installer is responsible for the installaon of the
appliance and compliance with local regulaons in maers of installaon. Under no circumstances can the
manufacturer be held liable in the event that local installaon standards are not respected.
Incorrect installaon may cause damage to property or serious injuries (possibly causing death),
It is important that this appliance be handled by skilled and apt persons (physically and mentally) having
received the instrucons for use beforehand (by reading these instrucons). All persons not meeng these
criteria must not approach the appliance in order to avoid exposure to dangerous elements.
Wiring and installaon must be carried out in accordance with local and federal regulaons regarding the
installaon of an electrical device in relaon to the pool with an IP24 rang.
If the appliance suers a malfuncon: do not try to repair the appliance yourself, contact your reseller,
Before any intervenon on the appliance, make sure it has been powered o and locked out, and that
heang priority has been deacvated.
Before any operaons check that:
-the voltage indicated on the appliance plate corresponds to the mains voltage,
-the power supply is suitable for use with a heat pump, and that it has a ground connecon.
Eliminang or shunng any safety devices automacally voids the warranty, as does the replacement of
parts using parts not originang from our warehouses,
Keep the appliance out of the reach of children,
Do not release R410A coolant liquid into the atmosphere. This is a uoride greenhouse eect gas covered
by the Kyoto agreement with a global warming potenal (GWP) = 1975.
This heat pump is compable with all types of water treatment.
Addional recommendaons relave to pressurised appliances (PED-97/23/EC)
Installaon and maintenance
It is prohibited to install the appliance close to combusble materials or close to the air intake on an adjacent
building.
For some appliances it is imperave to use the protecon grate accessory if the installaon is located in an
unregulated access area.
During installaon, repair, or maintenance operaons it is prohibited to use piping as a step ladder: under
stress the piping could rupture and the coolant could cause serious burns.
During maintenance of the appliance the composion and condion of the heat transporng uid will be
checked as will the absence of traces of coolant.
During the annual appliance seal inspecon in compliance with applicable regulaons, check that the high and
low pressure switches are correctly connected to the refrigeraon circuit and that they cut the electric circuit
when triggered.
During the maintenance phase make sure there are no traces of corrosion or oil stains around the refrigerang
components.
Before any operaons on the refrigerang circuit it is imperave to shut down the appliance and to wait a few
minutes before ng temperature or pressure sensors. Some equipment such as the compressor and piping
can reach temperatures in excess of 100°C and high pressures which can cause serious burns.
Repairs
All welding operaons are to be carried out by qualied welders
Piping can only be replaced using copper tube in compliance with NF EN 12735-1 standard.
Leak detecon, pressure test:
-never use oxygen or dry air, there is a risk of re and explosion,
-use dehydrated nitrogen or a mixture of nitrogen and the coolant indicated on the idencaon plate,
-the test pressure on the low and high pressure sides must not exceed 42 bar.
For the high pressure circuit piping using copper pipes of a diameter = or > than 1’’5/8, a §2.1 cercate under
standard NF EN 10204 is to be requested from the supplier and kept with the installaon technical documents.
The technical informaon relave to the safety requirements for the dierent applicable direcves is indicated
on the idencaon plate. All this informaon must be recorded on the appliance installaon manual which
must be part of the installaon technical le: model, code, serial number, maximum and minimum service
voltage and service pressure, year of manufacture, CE marking, manufacturers address, coolant type and
weight, electric parameters, thermodynamic and acousc performances.
3
Are available in the appendices at the end of these instrucons:
Electric Diagram
Size
Descripon
Contents
1. Informaon before installing ................................................................................................................... 4
1.1 General delivery terms and condions ...................................................................................................... 4
1.2 Technical specicaons ................................................................................................................................ 4
2. Installaon ....................................................................................................................................................... 4
2.1 Selecon of the locaon .............................................................................................................................. 4
2.2 Installing the appliance ................................................................................................................................ 4
2.3 Hydraulic connecons .................................................................................................................................. 5
2.4 Electric connecons ...................................................................................................................................... 5
3. Use ....................................................................................................................................................................... 6
3.1 Presentaon of the regulaon .................................................................................................................... 6
3.2 Checks before commissioning ..................................................................................................................... 6
3.3 Starng up the appliance ............................................................................................................................. 6
3.4 Checks to carry out once the appliance is running .................................................................................. 7
3.5 Wintering ........................................................................................................................................................ 7
4. Maintenance ................................................................................................................................................... 7
4.1 Maintenance instrucons ............................................................................................................................ 7
4.2 Recycling ......................................................................................................................................................... 7
5. Troubleshoong ............................................................................................................................................ 8
5.1 Displays ........................................................................................................................................................... 8
5.2 Appliance malfuncons ................................................................................................................................ 8
5.3 FAQ ................................................................................................................................................................... 9
6. Registering the product .............................................................................................................................. 9

Produktspecifikationer

Varumärke: Zodiac
Kategori: Värmare
Modell: Z200

Behöver du hjälp?

Om du behöver hjälp med Zodiac Z200 ställ en fråga nedan och andra användare kommer att svara dig




Värmare Zodiac Manualer

Zodiac

Zodiac Z200 Bruksanvisning

31 Augusti 2024

Värmare Manualer

Nyaste Värmare Manualer