Air King DRLC702 Bruksanvisning

Air King Fläkt DRLC702

Läs nedan 📖 manual på svenska för Air King DRLC702 (12 sidor) i kategorin Fläkt. Denna guide var användbar för 11 personer och betygsatt med 4.5 stjärnor i genomsnitt av 2 användare

Sida 1/12
IMPORTANT INSTRUCTIONS -
OPERATING MANUAL
SAVE THESE INSTRUCTIONS
www.airkinglimited.com
210572063 Rev. E 12-15 1 of 12
Exhaust Fan with Light
Models: DRLC701, DRLC702,
DRLC703, DRLC709
READ AND SAVE THESE INSTRUCTIONS
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN
THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY
INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL
INJURY AND/OR PROPERTY DAMAGE!
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
GENERAL SAFETY INFORMATION
When using electrical appliances, basic precautions should
always be followed to reduce the risk of fire, electric shock and
injury to person, including the following:
WARNING: TO REDUCE THE RISK
OF FIRE, ELECTRIC SHOCK AND INJURY TO
PERSON, OBSERVE THE FOLLOWING:
a) Use this unit only in the manner intended by the manufacturer.If you have
questions, contact the manufacturer.
b) Before servicing or cleaning the unit, switch power off at service
panel and lock the service disconnecting means to prevent power
from being switched on accidentally. When the service disconnecting
means cannot be locked, securely fasten a prominent warning
device, such as a tag, to the service panel.
WARNING: TO REDUCE THE RISK
OF FIRE, ELECTRIC SHOCK AND INJURY TO
PERSON, OBSERVE THE FOLLOWING:
a) Installation work and electrical wiring must be done by qualified
person(s) in accordance with all applicable codes and standards,
including fire-related construction.
b) Sufficient air is needed for proper combustion and exhausting of
gases through the flue (chimney) of fuel burning equipment to prevent
back drafting. Follow the heating equipment manufacturer’s guideline
and safety standards such as those published by the National Fire
Protection Association (NFPA) and the American Society for Heating,
Refrigeration, and Air Conditioning Engineers (ASHRAE), and the local
code authorities.
c) When cutting or drilling into wall or ceiling, do not damage electrical
wiring and other hidden utilities.
CAUTION: FOR GENERAL VENTILATING USE ONLY.
DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE
MATERIALS AND VAPORS.
d) Ducted fans must always be vented to the outdoors.
e) This unit must be grounded.
f) To avoid motor bearing damage and noisy and/or unbalanced impellers,
keep drywall spray, construction dust, etc. off power unit.
g) Read all instructions before installing or using exhaust fan.
WARNING: TO REDUCE THE RISK OF FIRE,
ELECTRIC SHOCK, DO NOT USE THIS FAN WITH
ANY SOLID-STATE SPEED CONTROL DEVICE.
WARNING: DO NOT INSTALL OVER A TUB OR MOUNT IN A
SHOWER STALL ENCLOSURE.
WARNING: DO NOT USE IN KITCHENS.
INSTALLATION INSTRUCTIONS
CAUTION: MAKE SURE POWER IS SWITCHED OFF AT
SERVICE PANEL BEFORE STARTING INSTALLATION.
SECTION 1
Preparing the Exhaust Fan
1. Unpack fan from the carton and confirm that all pieces are present. In addition to the
exhaust fan you should have:
1 - Grill with Glass Light Lens
1 - Damper Assembly (attached)
2 - #8 Screws
2 - Lockwashers
4 - Mounting Rails
1 - Instruction/Safety Sheet
2. Remove the fan’s venturi assembly, which is secured in place with one screw through the
venturi (Figure 1). This is a captive screw and will stay installed in the venturi. Keep the
venturi assembly and the grill in the carton until needed so they do not get damaged or lost.
3. Choose the location for your fan. To ensure the best
air and sound performance, it is recommended that
the length of ducting and the number of elbows be
kept to a minimum, and that insulated hard ducting be
used. Larger duct sizes will reduce noise and airflow
restrictions. This fan will require at least 6” of clearance
in the ceiling or wall, and will mount through drywall
up to 3/4 thick. The fan can be mounted directly to the
joist using the mounting tabs on the side of the housing
or between 16” on center joists using the 4 provided
mounting rails.
4. Select the most convenient electrical knockout and
remove using a straight-blade screw driver (Figure 2).
SECTION 2
New Construction
1a. Mounting Rail Installation: Install the rails on the housing and position the housing next to
the joist. Using the gauge on the fan’s housing, line up housing so that it will be flush with
the finished ceiling. Secure the ends of the rails with screws or nails (not included) to the
joists and slide the housing into the nal position (Figure 3).
1b. Mounting Tab Installation: Using the gauge on the fan’s housing, line up housing so that
it will be flush with the finished ceiling. Position the fan so that the tabs rest flat against the
joist and secure with four nails (not provided) to ensure proper installation (Figure 4).
www.airkinglimited.com
210572063 Rev. E 12-15 2 of 12
SECTION 3
Existing Construction
1a. Mounting Rail Installation: Set housing in position between the joist and trace an outline
onto the ceiling material . Set housing aside and cut opening, being careful not (Figure 5)
to cut or damage any electrical or other hidden utilities. Install the rails on the housing and
position the housing in the previously cut hole so that it is flush with the finished ceiling.
Secure the ends of the rails to the joists (Figure 3).
1b. Mounting Tab Installation: Position housing against the joist and trace an outline of the
housing onto the ceiling material . Set housing aside and cut opening, being (Figure 6)
careful not to cut or damage any electrical or other hidden utilities. Place housing next
to the joist and insure that it is flush with the finished ceiling. Secure with four nails (not
provided) to ensure proper installation (Figure 4).
SECTION 4
Ducting
CAUTION: ALL DUCTING MUST COMPLY WITH LOCAL AND NATIONAL
BUILDING CODES.
1. Connect the ducting to the fan’s duct collar . Secure in place using tape or (Figure 7)
screw clamp. Always duct the fan to the outside through a wall or roof cap.
Figure 3
Housing
Joist
Mounting Rails
Figure 2
Figure 5
Figure 4
Figure 6
Figure 1
NOTE: If damper detaches from unit, reattach by snapping the collar back onto the unit. It is
designed to only fit one way.
SECTION 5
Wiring
CAUTION: MAKE SURE POWER IS SWITCHED OFF AT
SERVICE PANEL BEFORE STARTING INSTALLATION.
CAUTION: ALL ELECTRICAL CONNECTIONS MUST BE
MADE IN ACCORDANCE WITH LOCAL CODES, ORDINANCES, OR
NATIONAL ELECTRICAL CODE. IF YOU ARE UNFAMILIAR WITH METHODS OF INSTALLING
ELECTRICAL WIRING, SECURE THE SERVICES OF A QUALIFIED ELECTRICIAN.
1. Wiring Fan/Light Independently: Run wiring from an approved wall switch carrying the
appropriate rating. One neutral (white), one ground (green or bare copper), and two hot
(black lead connected to the switch). Secure the electrical wires to the housing with an
approved electrical connector. Make sure you leave enough wiring in the box to make the
connection to the fan’s receptacle.
1a. From where you have access to inside the fan’s junction box, connect the one white wire
from the house to both the white wire from the fan’s light receptacle and the white wire
from the fan’s exhaust receptacle. Connect the first black wire from the wall switch to the
red wire from the fan’s light receptacle. Connect the second black wire from the switch to
the fan’s exhaust receptacle. Connect the ground wire from the house to the green wire
from the fan’s grounding screw Use approved methods for all connections.(Figure 8).
2. Wiring Fan/Light together: Run wiring from an approved wall switch carrying the
appropriate rating. One neutral (white), one ground (green or bare copper), and one hot
(black lead connected to the switch). Secure the electrical wires to the housing with an
approved electrical connector. Make sure you leave enough wiring in the box to make the
connection to the fan’s receptacle.
2a. From where you have access to inside the fan’s junction box, connect the one white wire
from the house to both the white wire from the fan’s light receptacle and the white wire
from the fan’s exhaust receptacle. Connect the black wire from the wall switch to both the
red wire from the fan’s light receptacle and the black wire from the fan’s exhaust receptacle.
Connect the ground wire from the house to the green wire from the fan’s grounding screw
(Figure 9). Use approved methods for all connections.
www.airkinglimited.com
210572063 Rev. E 12-15 3 of 12
SECTION 6
Completing the Installation
1. Reinstall the fan’s venturi by holding it at approximately a 45 degree angle, hook the two
tabs on the venturi into the slots on the housing and secure in place by tightening the
venturi screw. Rotate the blower wheel by hand to ensure it spins freely. Now plug the
fan motor into the receptacle (Figure 10).
2. Remove glass light lens from grill by unscrewing knob at the top of lens (Figure 11).
3. Plug cord from lamp holders into the appropriate receptacle .(Figure 12)
4. Line up slots in the grill with lances on inside of housing. Insert included #8 screws
through grill slots and into housing lances. Tighten both screws until the grillts snugly
to the ceiling. DO NOT OVER TIGHTEN (Figure 13).
CAUTION: FAILURE TO SECURE THE REFLECTOR BOLT MAY RESULT
IN A RATTLING OR HUMMING NOISE.
5. Install 2 - 60 watt maximum, type A19 medium base incandescent bulbs (not included).
Figure 10
Figure 7
Supply
from
house White
Hot (Black)
Ground
Figure 8 Hot (Red)
Figure 9
Supply
from
house
White
Hot (Black)
Ground
Hot (Red)
Figure 11
Glass Lens
Knob
Figure 12
Cord
Lamp
Holder
Figure 13 #8 Screws
Lances
Grill

Produktspecifikationer

Varumärke: Air King
Kategori: Fläkt
Modell: DRLC702

Behöver du hjälp?

Om du behöver hjälp med Air King DRLC702 ställ en fråga nedan och andra användare kommer att svara dig




Fläkt Air King Manualer

Fläkt Manualer

Nyaste Fläkt Manualer