Aube TH232-AF-230 Bruksanvisning
Läs nedan 📖 manual på svenska för Aube TH232-AF-230 (4 sidor) i kategorin Termostat. Denna guide var användbar för 7 personer och betygsatt med 4.5 stjärnor i genomsnitt av 2 användare
Sida 1/4
TH232-AF-230 400-232-003-B 2010-05-26 1/4
• One (1) thermostat
• One (1) floor sensor
• One (1) wall plate
Turn off power to the heating system at the main power panel to
avoid electrical shock. Installation should be carried out by an
electrician.
All work must conform to the applicable country standards for
electrical installations and wiring.
This thermostat should be connected on a circuit equipped with
a fuse or a circuit breaker. It must be installed on a certified
electrical box equipped with non-metallic cable strain relief
adapters. Use separate adapters for the high-voltage wires and
for the sensor cable.
For a new installation, choose a location about 1.5 m above the
floor.
For electric baseboards, convectors and fan-forced heaters, the
thermostat must be installed facing the heating system and on
an inside wall.
Avoid locations where there are air drafts (top of staircase, air
outlet), dead air spots (behind a door), direct sunlight or
concealed chimneys or stove pipes.
NOTE: The terminals are designed to handle a cross-section of wire
measuring 0.33 to 3.1 mm2.
Loosen the captive screw underneath the base and remove the
faceplate from the base.
Before making the connections, make sure
that the base covers the electrical box
entirely. If not, install a wall plate at the
back of the base.
Connect the wires:
• :Power
Terminals 1 & 5
• Load:
Terminals 2 & 4
see note 1
• Pilot Wire:
Terminal 3
see note 2
• :Floor sensor
Terminals 6 & 7
(no polarity)
see note 3
WARNING: Ensure that the wires are tightly secured to the terminals.
Apply a minimum torque of 0.5 Nm (4.4 Lb/in) when tightening the
screws.
Note 1 If a contactor is used between the thermostat and the load,
install a snubber at the contactor’s coil terminal to ensure
the proper operation of the thermostat.
Note 2 This connection is required on some models only.
Note 3 The sensor cable must pass outside the electrical box and
travel inside the wall to the floor. For the proper operation of
the thermostat, the floor sensor must be centered between
two heater wires having a maximum temperature of 80 °C
(176 °F). The floor sensor wire must not cross any heater
wire or be placed close to it.
Push wires into the electrical box and
secure the base to the electrical box
anchorage. The head of the screw
must be less than 2 mm thick.
Return the faceplate
to the base.
Return power to the heating system.
NOTE: Keep the thermostat's air vents clean and unobstructed at all
times.
1.
2.
3.
Base
Faceplate
TH232-AF-230 400-232-003-B 2010-05-26 2/4
This thermostat provides the following temperature control modes:
Display
Apply power to the thermostat at the main electrical panel. At
power-up, the thermostat is in manual mode and displays the
actual (measured) temperature. The setpoint temperature is 28 °C
(82 °F).
LO The actual temperature is below 0 °C (32 °F).
HI The actual temperature is above 70 °C (158 °F).
Er The thermostat built-in sensor is defective. Replace the
thermostat.
E1 The floor sensor circuit is opened. Check the sensor
connections.
E2 The floor sensor circuit is shorted. Replace the sensor.
Press and hold the Clear button for 3 seconds. The current con-
trol mode is displayed ( )ctl .
Press the to select between A, AF and F.
NOTE
: If you have chosen the A or F mode, go to step 7. If you have
chosen the AF mode, the thermostat will control the ambient tempera-
ture while keeping the floor temperature within desired limits. If the
floor temperature is too low or too high, the thermostat will turn heating
on or off to maintain the floor temperature within the limits regardless
of the ambient temperature. The minimum and maximum floor temper-
ature limits are factory-set at 5 °C (41 °F) and 28 °C (82 °F) respec-
tively. To modify the limits, continue with the next step:
Press the
Clear
button briefly. The minimum limit is displayed (
FL:LO
).
Press the button to set the minimum limit.
Press the
Clear
button briefly. The maximum limit is displayed (
FL:HI
).
Press the buttons to set the maximum limit.
Press the Mode/Return button to exit and
save the changes.
NOTE: If no button is pressed for 60 seconds, the thermostat will
save the changes and return to normal display.
This procedure allows you to choose the following configurations:
Press and hold the Pgm button for 3 seconds. The current tem-
perature unit is displayed (unit).
Press the to toggle between °C and
°F.
Press the Pgm button briefly. The current time format is dis-
played (Hr).
Press the to toggle between 24H and 12H.
Press the Pgm button briefly. The current Early Start setting is
displayed (ES).
Press the to toggle between OFF and On.
Press the Mode/Return button to exit and
save the changes.
1.
A mode: controls and displays the ambient air temperature
F mode: controls and displays the floor temperature using
an external temperature sensor (default mode)
AF mode: controls and displays the ambient air temperature
maintains the floor temperature within desired
limits using an external temperature sensor
2.
3.
Day and
time setting
Schedule
programming
Mode selection /
Exit
Clear
Temperature
adjustment
Temperature
presets
On/Off button *
* Use this button to disable heating (e.g. in the summer). The
thermostat remains powered and continues to display the time
and temperature.
Time
Day
Temperature
Periods
Heating intensity
indicator
Automatic mode
Appears when the
setpoint temperature
is displayed
Appears when
heating is disabled
Mode indicator (A, F or AF)
Preset temperature
indicators
Manual mode
4.
Parameters Default settings
Temperature format °C
Time format 24H
Early Start setting (see the note below) On
TH232-AF-230 400-232-003-B 2010-05-26 3/4
NOTE: Early Start can be used in Automatic mode only. When this
function is set to On, the thermostat calculates the optimal time to
start heating in order to obtain the desired temperature by the set
time. The thermostat re-assesses the start time daily based on the
previous day’s results.
Press the button to set the hour.Hour
Set the Min button to set the minutes.
Set the Day button to set the day.
Press Mode/Return to exit and save the changes.
Daylight Savings (DLS) Time
When the DLS function is set to US, the thermostat switches to Day-
light Savings Time on the second Sunday of March and to normal
time on the first Sunday of November.
When the DLS function is set to Eu, the thermostat switches to Day-
light Savings Time on the last Sunday of March and to normal time
on the last Sunday of October.
NOTE: The DLS function is OFF (default setting) when the clock
loses its setting.
Press the Day button (3 seconds) until DLS appears
on the screen.
Press the to toggle between US, Eu
and OFF.
Press the Day button briefly. The year setting is dis-
played.
Press the to set
the current year.
Press the Day button briefly. The month setting is dis-
played.
Press the to set the current month.
Press the Day button briefly. The date setting is dis-
played.
Press the to set the current date.
Press Mode/Return to exit and save the changes.
The thermostat normally displays the actual (measured) temperature.
To view the setpoint, press one of the buttons once. The setpoint
will appear for the next 5 seconds.
To change the setpoint, press one of the buttons until the desired
temperature is displayed. To scroll faster, press and hold the button.
Backlight
The screen is lit for 12 seconds when any button is pressed.
The thermostat has 2 preset temperatures:
Comfort temperature
Economy temperature
To use a preset temperature, press the corresponding button. The
corresponding icon will be displayed.
The following table shows the intended use and the default value of
each of the preset temperatures.
To store a preset temperature:
Set the desired temperature using the buttons.
Press and hold the corresponding temperature preset button
until the corresponding icon is displayed.
The thermostat has 2 modes of operation: automatic mode and man-
ual mode.
Use automatic mode if you want the thermostat to fol-
low the programmed schedule. The schedule has 4
time periods and uses the 2 preset temperatures. The
thermostat switches to Comfort temperature in periods
1 and 3 and to Economy temperature in periods 2 and
4. The following table shows the intended use of each
time period.
To use the automatic mode, press the Mode button to display on
the screen. The current period number will also appear.
Preprogrammed schedule
The thermostat has been programmed with the following schedule.
Temporary bypass
You can override the temperature of the current period by pressing
the , or buttons. The new setpoint will be used until the begin-
ning of the next period. The clock icon flashes during the bypass.
To cancel the bypass, press the Mode button.
5.
6.
Icon Intended use A/AF modes F mode
Comfort
(when at home) 21 °C (70 °F) 28 °C (82 °F)
Economy (when asleep
or away from home) 16.5 °C (62 °F) 20 °C (68 °F)
7.
Period Temperature setting Typical use
Comfort Wake-up
Economy At work
Comfort At home
Economy Sleep
Period Temperature
setting
Period start time
MO TU WE TH FR SA SU
Comfort 6:00
am
6:00
am
6:00
am
6:00
am
6:00
am
6:00
am
6:00
am
Economy 8:30
am
8:30
am
8:30
am
8:30
am
8:30
am --:-- --:--
Comfort 4:00
pm
4:00
pm
4:00
pm
4:00
pm
4:00
pm --:-- --:--
Economy 11:00
pm
11:00
pm
11:00
pm
11:00
pm
11:00
pm
11:00
pm
11:00
pm
Produktspecifikationer
Varumärke: | Aube |
Kategori: | Termostat |
Modell: | TH232-AF-230 |
Färg på produkten: | Black, Stainless steel |
Vikt: | 2300 g |
Bredd: | 380 mm |
Djup: | 266 mm |
Höjd: | 21 mm |
Batterikapacitet: | 2950 mAh |
AC-adapterfrekvens: | 50 - 60 Hz |
AC-adapterns inspänning: | 100 - 240 V |
Blåtand: | Nee |
Skärm diagonal: | 15.6 " |
Upplösning: | 1366 x 768 Pixels |
Pekskärm: | Nee |
Original bildförhållande: | 16:9 |
Processorfrekvens: | 1.7 GHz |
Processorfamilj: | Intel® Core™ i5 |
Processormodel: | i5-3317U |
Antal processorkärnor: | 2 |
Wi-Fi-standarder: | 802.11b, 802.11g, Wi-Fi 4 (802.11n) |
Vormfaktor: | Clamshell |
Inkluderar operativsystem: | Windows 8 |
Ethernet LAN: | Ja |
Integrerad minneskortläsare: | Ja |
Kompatibla minneskort: | SD |
Ljudsystem: | SonicMaster Lite |
Processor litografi: | 22 nm |
LED-bakgrundsbelysning: | Ja |
Antal USB 2.0-portar: | 2 |
VGA (D-Sub) port(ar): | 1 |
Antal HDMI-portar: | 1 |
DVI-port: | Nee |
Antal Ethernet LAN (RJ-45)-portar: | 1 |
Monteringsalternativ för kabellås: | Nee |
Inbyggda högtalare: | Ja |
AC-adapter, ström: | 65 W |
HD typ: | HD |
Inbyggd mikrofon: | Ja |
Internminne: | 4 GB |
3D: | Nee |
Förvarings media: | HDD |
Batteritid/batteritid: | - uur |
Internminnestyp: | DDR3-SDRAM |
Ethernet LAN, dataöverföringshastigheter: | 10,100,1000 Mbit/s |
Kabelteknik: | 10/100/1000Base-T(X) |
Intel® Wireless Display (Intel® WiDi): | Ja |
Antal portar USB 3.2 Gen 1 (3.1 Gen 1) Typ A: | 1 |
Processoruttag: | BGA 1023 |
Stepping: | L1 |
Systembuss: | 5 GT/s |
Processor antal trådar: | 4 |
PCI Express-kortplatsversion: | 2.0 |
Processorns driftlägen: | 64-bit |
Processorns cache: | 3 MB |
Tjunction: | 105 °C |
Busstyp: | DMI |
PCI Express-konfigurationer: | 1x16, 2x8, 1x8+2x4 |
Thermal Design Power (TDP): | 17 W |
Kodnamnsprocessor: | Ivy Bridge |
Maximalt antal PCI Express-linjer: | 16 |
Typ av processorcache: | Smart Cache |
ECC stöds av processor: | Nee |
Processorfabrikant: | Intel |
Maximalt internminne: | 8 GB |
Total lagringskapacitet: | 500 GB |
Typ av optisk enhet: | DVD Super Multi |
Inbyggd grafikadapter: | Ja |
Separat grafikadapter: | Ja |
Familjens inbyggda grafikadapter: | Intel® HD Graphics |
Inbyggd grafikadaptermodell: | Intel® HD Graphics 4000 |
Grundläggande frekvens inbyggd grafikadapter: | 350 MHz |
Inbyggd grafikadapter dynamisk frekvens (max): | 1050 MHz |
Inbyggt grafikkort-ID: | 0x166 |
Numerisk knappsats: | Ja |
Instruktionsuppsättningar som stöds: | AVX |
Intel® My WiFi Technology (Intel® MWT): | Ja |
Intel® Hyper Threading Technology (Intel® HT Technology): | Ja |
Intel® Turbo Boost-teknik: | 2.0 |
Intel® Quick Sync-videoteknik: | Ja |
Intel® InTru™ 3D-teknik: | Ja |
Intel® Clear Video HD-teknik (Intel® CVT HD): | Ja |
Intel® Insider™: | Ja |
Intel® Flex Memory Access: | Ja |
Intel® AES nya instruktioner (Intel® AES-NI): | Ja |
Förbättrad Intel SpeedStep-teknik: | Ja |
Kör Disable Bit: | Ja |
Idle stater: | Ja |
Termisk övervakningsteknik: | Ja |
CPU-konfiguration (max): | 1 |
Intel® Enhanced Halt State: | Ja |
Intel® Clear Video Technology för mobila internetenheter (Intel® CVT för MID): | Nee |
Intel® VT-x med utökade sidtabeller (EPT): | Ja |
Inbyggda alternativ tillgängliga: | Nee |
Grafik & IMC litografi: | 22 nm |
Intel® Secure Key: | Ja |
Intel® 64: | Ja |
Intel® Virtualization Technology for Directed I/O (VT-d): | Ja |
Intel® Clear Video-teknik: | Nee |
Intel® Virtualization Technology (VT-x): | Ja |
Processorpaketstorlek: | 31.0 x 24.0 mm |
Konfliktfri processor: | Ja |
Intel® Identity Protection Technology (Intel® IPT): | Ja |
Versie Intel® Identity Protection Technology: | 1.00 |
Versie Intel® Secure Key Technology: | 1.00 |
ARK ID-processor: | 65707 |
Intel® Trusted Execution Technology: | Nee |
Intel® Anti-Theft Technology (Intel® AT): | Ja |
Kombinerad hörlurs/mikrofonport: | Ja |
SmartCard-kortplats: | Nee |
Nätverksfunktioner: | Gigabit Ethetrnet, WLAN |
Maximal processorturbofrekvens: | 2.6 GHz |
Processorkod: | SR0N8 |
Diskret grafikadaptermodell: | NVIDIA® GeForce® GT 635M |
Pekdon: | Touchpad |
AC-adapter, utspänning: | 19 V |
AC-adapter, utström: | 3.42 A |
Klockhastighetsminne: | 1600 MHz |
Minnesplatser: | 2x SO-DIMM |
Chipset moderkort: | Intel HM76 Express |
Specifik grafikminnestyp: | GDDR3 |
Grafikminne: | 2 GB |
Antalet installerade hårddiskar: | 1 |
HDD kapacitet: | 500 GB |
HDD-gränssnitt: | SATA |
CPU-multiplikator (bus/kärnförhållande): | 17 |
FSB-paritet: | Nee |
Bussprocessor på framsidan: | - MHz |
Intel® efterfrågebaserad växling: | Nee |
Typ av laddningsport: | DC-in ingang |
Medföljande drivrutiner: | Ja |
Typ CardBus PCMCIA-slot: | Nee |
Processorserie: | Intel Core i5-3300 Mobile series |
ExpressCard-kortplats: | Nee |
S/PDIF-utgång: | Nee |
Intel® Dual Display Capable Technology: | Ja |
Intel® FDI-teknik: | Ja |
Intel® Rapid Storage Technology: | Nee |
Intel® Fast Memory Access: | Ja |
Intel® Smart Cache: | Ja |
HDD storlek: | 2.5 " |
Wifi: | Ja |
Typ produkt: | Notebook |
Antal battericeller: | 4 |
Integrerad 4G WiMAX: | Ja |
Processorgenerering: | Derde generatie Intel® Core™ i5 |
Batterijcapaciteit: | 44 Wh |
Behöver du hjälp?
Om du behöver hjälp med Aube TH232-AF-230 ställ en fråga nedan och andra användare kommer att svara dig
Termostat Aube Manualer
26 Juli 2024
Termostat Manualer
- Termostat ATAG
- Termostat Bosch
- Termostat AEG
- Termostat Panasonic
- Termostat Honeywell
- Termostat Junkers
- Termostat Nefit
- Termostat Remeha
- Termostat Siemens
- Termostat Vaillant
- Termostat Ambiano
- Termostat Amfra
- Termostat Google
- Termostat Silvercrest
- Termostat Renkforce
- Termostat Itho
- Termostat De Dietrich
- Termostat TP Link
- Termostat Elro
- Termostat EMOS
- Termostat Truma
- Termostat Energenie
- Termostat Schneider
- Termostat Hama
- Termostat Fenix
- Termostat Theben
- Termostat Elektrobock
- Termostat Devi
- Termostat Stiebel Eltron
- Termostat Buderus
- Termostat Dimplex
- Termostat Emerson
- Termostat Vemer
- Termostat Ferroli
- Termostat Magnum
- Termostat Horstmann
- Termostat Salus
- Termostat Perel
- Termostat Tylö
- Termostat Somfy
- Termostat Corberó
- Termostat Oventrop
- Termostat King
- Termostat Arnold Rak
- Termostat Cotech
- Termostat Heatmiser
- Termostat Viessmann
- Termostat Carrier
- Termostat Nest
- Termostat Itho-Daalderop
- Termostat Danfoss
- Termostat Saunier Duval
- Termostat Netatmo
- Termostat Seitron
- Termostat Bticino
- Termostat Sygonix
- Termostat Tado
- Termostat Hunter
- Termostat Plieger
- Termostat Busch-Jaeger
- Termostat UPM
- Termostat Optima
- Termostat AWB
- Termostat Finder
- Termostat Fantini Cosmi
- Termostat Delta Dore
- Termostat Orbis
- Termostat EBERLE
- Termostat Grasslin
- Termostat Gira
- Termostat Jung
- Termostat Basetech
- Termostat HQ
- Termostat Eneco
- Termostat Frico
- Termostat Vasco
- Termostat Nobo
- Termostat Baxi
- Termostat Fibaro
- Termostat EQ3
- Termostat Homematic IP
- Termostat Go Green
- Termostat Landis Gyr
- Termostat Weishaupt
- Termostat ICY
- Termostat Computherm
- Termostat Avidsen
- Termostat Heimeier
- Termostat Crestron
- Termostat ORNO
- Termostat Drayton
- Termostat Cepra
- Termostat Heatit
- Termostat 2Heat
- Termostat Watts
- Termostat Etherma
- Termostat Emmeti
- Termostat Thermy
- Termostat Eurotronic
- Termostat Oregon Scientific
- Termostat Muller
- Termostat Econo-Heat
- Termostat Vimar
- Termostat PECO
- Termostat H-Tronic
- Termostat Intertechno
- Termostat Schwaiger
- Termostat EQ-3
- Termostat Tru Components
- Termostat Emko
- Termostat IMIT
- Termostat Innogy
- Termostat Maico
- Termostat HomePilot
- Termostat Ouellet
- Termostat Techno Line
- Termostat THERMAFLEX
- Termostat Wachendorff
- Termostat Yokis
- Termostat Eliwell
- Termostat Plugwise
- Termostat Johnson Control
- Termostat Drayton Erie
- Termostat Tellur
- Termostat RWE
- Termostat Lowes
- Termostat Jumo
- Termostat Warmup
- Termostat Qubino
- Termostat STI
- Termostat ELKO
- Termostat TrickleStar
- Termostat Gewiss
- Termostat Sinustec
- Termostat Rose LM
- Termostat Otio
- Termostat MundoControl
- Termostat Enda
- Termostat Bearware
- Termostat GENERAL Life
- Termostat Oreg
Nyaste Termostat Manualer
27 Oktober 2024
27 Oktober 2024
26 Oktober 2024
26 Oktober 2024
26 Oktober 2024
26 Oktober 2024
26 Oktober 2024
26 Oktober 2024
26 Oktober 2024
26 Oktober 2024