USER GUIDE
www.bxterra.com
MODBUS CARD
MODBUS 110
1
PRODUCT INTRODUCTION
INSTALLATION & OPERATION
Thank you for purchasing this bXterra Modbus card. This manual contains instructions
and warnings that should be followed during the installation, operation and storage of
the card. Please keep this manual for future reference.
Special Precautions
• If the card is stored prior to installation, it must be stored in a dry place
• The admissible storage temperature range is from 14ºF to 158ºF
1. RS-485 port 2. Address switch
3. Communication setting
4. Resistance switch
The Modbus card provides UPS systems with the functionality of communication with
PCs through the Modbus protocol it also:
• Implements Modbus RTU protocol
• Provides Modbus functions including read Holding Registers and write Registers
• Provides RS-485 interface
• Provides surge protection
Follow these steps to install and use this Modbus card:
1. for details)Congure Modbus ID (Refer to the Machine ID Conguration
2. for details)Congure communication format (Refer to Communication Format
3. Insert this Modbus card into the Network slot of your UPS
4. Connect the Modbus card to a computer with a RJ-45 cable, and it is not necessary to
turn the UPS o during card installation (Refer to the Connection section for details)
2
CONFIGURATION
Machine ID Conguration
Communication Format Conguration
RS-485 Resistance Conguration
There are eight bits to used present
the ID of each card. Use SW1 to set the
machine ID. From left to right, it’s 8 to
1. As shown in the diagram, when the
switch is pushed down, the bit is set to
“1”. Otherwise, the bit is set as “0”. The
ID of the Modbus card is set to 0x01 as
shown in the chart. Please check the
appendix for detailed ID number and
SW1 settings.
FUNCTION BIT SETTING MEANING
Baud
Rate
# 2 # 1
OFF OFF 2400bps
OFF ON 4800bps
ON OFF 9600bps
ON ON 19200bps(default)
Parity
Check
# 4 # 3
OFF OFF Even parity
ON OFF Odd parity
OFF ON No parity check 1 stop
bits (Default)
ON ON No parity check 2 stop
bits
Function Bit# Setting Meaning
Push up
resistance # 6
ON Enable (Default)
OFF Disable
Push down
resistance # 7
ON Enable (Default)
OFF Disable
Terminate
resistance # 8
ON Enable (Default)
Disable
Produktspecifikationer
Varumärke: | Bxterra |
Kategori: | UPS |
Modell: | MODBUS-110 |
Behöver du hjälp?
Om du behöver hjälp med Bxterra MODBUS-110 ställ en fråga nedan och andra användare kommer att svara dig
UPS Bxterra Manualer
19 September 2024
19 September 2024
19 September 2024
19 September 2024
19 September 2024
19 September 2024
19 September 2024
19 September 2024
19 September 2024
19 September 2024
UPS Manualer
- UPS AEG
- UPS IKEA
- UPS HP
- UPS Siemens
- UPS Apc
- UPS LC-Power
- UPS Tripp Lite
- UPS Energenie
- UPS Voltcraft
- UPS Emerson
- UPS Adj
- UPS Digitus
- UPS LevelOne
- UPS Eaton
- UPS Jung
- UPS CyberPower
- UPS Block
- UPS Liebert
- UPS Avocent
- UPS Minuteman
- UPS Maruson
- UPS V7
- UPS Vanson
- UPS Salicru
- UPS Equip
- UPS Approx
- UPS SurgeX
- UPS Murr Elektronik
- UPS Altronix
- UPS Ditek
- UPS Middle Atlantic
- UPS FSP
- UPS Atlantis Land
- UPS PowerWalker
- UPS FSP/Fortron
- UPS Online USV
Nyaste UPS Manualer
24 Oktober 2024
22 Oktober 2024
22 Oktober 2024
22 Oktober 2024
20 Oktober 2024
18 Oktober 2024
18 Oktober 2024
13 Oktober 2024
13 Oktober 2024
13 Oktober 2024