Drayton RTS10 Bruksanvisning
Läs nedan 📖 manual på svenska för Drayton RTS10 (2 sidor) i kategorin Termostat. Denna guide var användbar för 8 personer och betygsatt med 4.5 stjärnor i genomsnitt av 2 användare
Sida 1/2
RTS Thermostat
Installation instructions
Models
RTS1: Standard heating thermostat
RTS2 Heating thermostat with call for heat LED indicator
RTS3: Indoor frost thermostat
RTS4 Volt free heating/cooling change over switch
RTS9 & 10: Volt free heating/cooling changeover switch with call
for heating LED indicator
IMPORTANT NOTE
RTS thermostats are ELECTRONIC with a relay output.
Unless connected to a 230V mains supply the relay will
not operate, no 'click' will be heard and the call for heat
contact will remain open.
Location
Care should be taken to mount the thermostat in a position
which is not subject to direct sunlight or draughts. Preferably
it should be mounted on an inside wall about 1.5m (5ft)
above the floor in a position where it can respond to room
temperature but away from the direct influence of radiators
or other appliances giving off heat.
Note: If the thermostat is to be used as a frost protection
device it should be located in the coldest part of the premises.
Fixing
1. Loosen the securing screws, remove the wall-plate and, if
surface wiring is to be used, snap out the cable entry strip
on the bottom edge of the wall-plate with a pair of pliers.
2. Fix the wall-plate, terminals at the top, either direct onto a
flat wall using wall plugs and No 6 x 1” woodscrews or on a
flush mounting single conduit box using M 3.5 x 14 screws.
3. Complete the wiring to the wall-plate in accordance with
the relevant diagram shown overleaf in accordance with
I.E.E. regulations.
Note: The thermostat is for fixed wiring only and is double
insulated, the earthing continuity (loop) terminal is only
provided for convenience.
4. Plug the thermostat onto the wall-plate and tighten the
securing screws.
5. Before switching on the mains ENSURE THE CIRCUIT
FUSE IS 3A.
WARNING
Disconnect mains supply before fitting or removing from
wall-plate.
A switch having contact separation of at least 3mm in all
poles must be incorporated in the fixed wiring as a means
of providing full disconnection of the mains supply.
Setting
1. Set the desired room temperature on the control knob
against the setting mark.
2. The setting range may be limited or a particular setting
locked through the use of the mechanism to be found
under the control knob.
3. To adjust the limiters firstly set the thermostat to the
desired temperature and then carefully pull off the knob.
4. Lift and rotate the two limiting arms to re-position them in
the required notches.
5. Replace the knob with the previously set temperature
against the setting mark.
Technical data
Electrical supply: 230V ac 50Hz fused 3A
Double insulated (no earth required)
Temp. range: RTS1, 2, 4 & 9 10 to 30 C° °
RTS3 (Frost) 3 to 10 C° °
Switch type: 3 S.P.S.T 2(1)A 230V ac live RTS 1, 2 &
output
RTS4, 9 & 10 eS.P.D.T 2(1)A 230V ac volt fre
Temp. sensor: Electronic
RTS10 14 to 30 C° °
06490053001 Iss B
0205
Customer Service Tel: +44 (0) 845 130 5522
Technical Helpline Tel: +44 (0) 845 130 7722
Room thermostats
Make Model
Drayton RTS 1 & 2 N L 3
Drayton RTS 4, 5, 9 & 10 NL 21 3
2311 tatsigiDnotyarD
ACL Lifestyle PT271/371 N L 21 3
ACL Lifestyle TS 142 E 4 1 2
ACL Lifestyle TA 350 5 21 3
Drayton Digistat (old version) 4 31 2
Drayton RT & RTE 4 31 2
Danfoss Randall TP1 E N L 1 2
2315 & 4 ,3 ,2PT .1TRlladnaR ssofnaD
Danfoss Randall RD3, RD3A 4 1 2
Danfoss Randall RTC, RTM, RSR E N 23 1
213N405RlladnaR ssofnaD
Honeywell 6060, 6061, 6063 2 41 3
CBA002TCllewyenoH
Horstman HRT 1 E 4 1 2
Landis & Gyr RAD 1 E 31 2
Potterton PRT 1 N L H
Potterton PRT 2 & 100 ST N TL H
Potterton PRT 100 DT N TL H C
Sunvic TLX 2259 E N L 1 2
Sunvic TLX 2356 E 23 1
Sopac TA 350 E 21 3
Sopac TA 351 E 4 21 3
Switchmaster SRT 2 5 21 3
Tower SS E 4 1 2
Earth
Neutral
Live
Common
Demand
Satisfied
Wiring (schematic)
Note: It is essential to make a neutral connection to terminal N.
Note: Link between terminals L and 1 if mains voltage is
required on the thermostat switch.
Information
The RTS room thermostat replaces earlier models of both
ACL and Drayton room thermostats subject to a maximum
load of 2(1)A 230V ac. The wiring conversion between
these models is:
ACL ACL Drayton RTS RTS
TS142 TA350 Roomstat 1,2 4, 9,
RT (E) & 3 & 10
Live supply 1 – 1 L L
Neutral 4 – 4 N N
(accelerator heater)
Call for heat 2 3 2 3 3
Heating satisfied – 2 3 – 2
(call for cooling)
Volt free – 1 – – 1
switch common
Earth connection E 5 – – –
Conforms to the essential requirements of the following
directives:
Relevant EC Directives
2006/95/EC Low Voltage Directive
2004/108/EC Electromagnetic
Compatibility Directive
2011/65/EU RoHS Directive
Applied Standards
EN60730-1, EN60730-2-9
N L 1 2 3
N
230V AC 50HZ
fused 3A
LCall for
heat
RTS1, RT S2 and RTS3
N L 1 2 3
N
230V AC 50HZ
fused 3A
L
Call for
heat
RTS4 TS9 nd, R a RTS10
COM
Heating o satisfied
r
call fo coolinr g
Energy Class: IV = 2%
(According to EU
811/2013, 812/2013,
813/2013, 814/2013)
Produktspecifikationer
Varumärke: | Drayton |
Kategori: | Termostat |
Modell: | RTS10 |
Behöver du hjälp?
Om du behöver hjälp med Drayton RTS10 ställ en fråga nedan och andra användare kommer att svara dig
Termostat Drayton Manualer
17 Oktober 2024
17 Oktober 2024
17 Oktober 2024
17 Oktober 2024
17 Oktober 2024
5 Oktober 2024
25 September 2024
25 September 2024
25 September 2024
25 September 2024
Termostat Manualer
- Termostat ATAG
- Termostat Bosch
- Termostat AEG
- Termostat Panasonic
- Termostat Honeywell
- Termostat Junkers
- Termostat Nefit
- Termostat Remeha
- Termostat Siemens
- Termostat Vaillant
- Termostat Ambiano
- Termostat Amfra
- Termostat Google
- Termostat Silvercrest
- Termostat Renkforce
- Termostat Itho
- Termostat De Dietrich
- Termostat TP Link
- Termostat Elro
- Termostat EMOS
- Termostat Truma
- Termostat Energenie
- Termostat Schneider
- Termostat Hama
- Termostat Fenix
- Termostat Theben
- Termostat Elektrobock
- Termostat Devi
- Termostat Stiebel Eltron
- Termostat Buderus
- Termostat Dimplex
- Termostat Emerson
- Termostat Vemer
- Termostat Ferroli
- Termostat Magnum
- Termostat Horstmann
- Termostat Salus
- Termostat Perel
- Termostat Tylö
- Termostat Somfy
- Termostat Corberó
- Termostat Oventrop
- Termostat King
- Termostat Arnold Rak
- Termostat Cotech
- Termostat Heatmiser
- Termostat Viessmann
- Termostat Carrier
- Termostat Nest
- Termostat Itho-Daalderop
- Termostat Danfoss
- Termostat Saunier Duval
- Termostat Netatmo
- Termostat Seitron
- Termostat Bticino
- Termostat Sygonix
- Termostat Tado
- Termostat Hunter
- Termostat Plieger
- Termostat Aube
- Termostat Busch-Jaeger
- Termostat UPM
- Termostat Optima
- Termostat AWB
- Termostat Finder
- Termostat Fantini Cosmi
- Termostat Delta Dore
- Termostat Orbis
- Termostat EBERLE
- Termostat Grasslin
- Termostat Gira
- Termostat Jung
- Termostat Basetech
- Termostat HQ
- Termostat Eneco
- Termostat Frico
- Termostat Vasco
- Termostat Nobo
- Termostat Baxi
- Termostat Fibaro
- Termostat EQ3
- Termostat Homematic IP
- Termostat Go Green
- Termostat Landis Gyr
- Termostat Weishaupt
- Termostat ICY
- Termostat Computherm
- Termostat Avidsen
- Termostat Heimeier
- Termostat Crestron
- Termostat ORNO
- Termostat Cepra
- Termostat Heatit
- Termostat 2Heat
- Termostat Watts
- Termostat Etherma
- Termostat Emmeti
- Termostat Thermy
- Termostat Eurotronic
- Termostat Oregon Scientific
- Termostat Muller
- Termostat Econo-Heat
- Termostat Vimar
- Termostat PECO
- Termostat H-Tronic
- Termostat Intertechno
- Termostat Schwaiger
- Termostat EQ-3
- Termostat Tru Components
- Termostat Emko
- Termostat IMIT
- Termostat Innogy
- Termostat Maico
- Termostat Levica
- Termostat HomePilot
- Termostat Ouellet
- Termostat Techno Line
- Termostat THERMAFLEX
- Termostat Wachendorff
- Termostat Yokis
- Termostat Eliwell
- Termostat Plugwise
- Termostat Johnson Control
- Termostat Webasto
- Termostat Drayton Erie
- Termostat Tellur
- Termostat RWE
- Termostat Lowes
- Termostat Jumo
- Termostat Warmup
- Termostat Qubino
- Termostat STI
- Termostat ELKO
- Termostat TrickleStar
- Termostat Gewiss
- Termostat Sinustec
- Termostat Rose LM
- Termostat Otio
- Termostat MundoControl
- Termostat Enda
- Termostat Bearware
- Termostat GENERAL Life
- Termostat Oreg
Nyaste Termostat Manualer
27 Oktober 2024
27 Oktober 2024
26 Oktober 2024
26 Oktober 2024
26 Oktober 2024
26 Oktober 2024
26 Oktober 2024
26 Oktober 2024
26 Oktober 2024
26 Oktober 2024