Fluke-700HTH-1
Hydraulic Test Hose
Instruction Sheet
Introduction
The Fluke-700HTH-1 Hydraulic Test Hose is designed to
work with the Fluke-700HTP-1 Hydraulic Test Pump. It is
self-sealing, with an easy, finger-tight connection, and low
volumetric expansion. The hose has the following
specifications:
Maximum pressure: 690 bar / 10,000 psi
Minimum bend radius: 60 mm / 2.36 in.
Working temperature: - 40 º ºC to + 120 C
( - 40 ºF to + 250 ºF)
Construction: nylon, stainless steel, zinc, plated steel,
and nitrile
Outer diameter: 6.0 mm (0.20 in.)
Fluids: water, mineral-based hydraulic oil
Box Contents
(1) .84 m (33 in) self-sealing hose assembly
(2) ¼ in NPT male hose fittings
(1) Adapter: 1/4 in NPT female to 1/4 in BSP male
Instruction Sheet
Contacting Fluke
To contact Fluke or for service, call one of the following
telephone numbers:
USA: 1-888-44-FLUKE (1-888-443-5853)
Canada: 1-800-36-FLUKE (1-800-363-5853)
Europe: +31 402-675-200
Japan: +81-3-3434-0181
Singapore: +65-738-5655
Anywhere in the world: +1-425-446-5500
Or, visit Fluke's Web site at www.fluke.com.
2
3
1
eve01f.eps
A Master Pressure Port
B Test Pressure Port
C Tee
BAA
eve02f.eps
A Hose Fitting
B Hose Assembly
700HTH-1
Instruction Sheet
2
Guidelines for Use
W Warning
To prevent personal injury, do not exceed
working pressure and ensure that all
connections are made correctly. Pressure built
up internally during use can be extremely high.
Uncontrolled release of high pressure can be
hazardous to individuals and may cause
damage to equipment.
1. Connect hose fitting to the test pressure port of the
700HTP-1 pump.
2. Connect other hose fitting to item under test.
3. Ensure hose connections are fully screwed down
before applying pressure.
4. Only use mineral-based hydraulic oil or distilled water.
5. Do not attempt to use hose if there are any signs of
damage to the outer covering, i.e., cuts, kinks, etc.
6. Do not bend hose more than the minimum bend radius
of 60 mm (2.36 inches).
7. Do not attempt to connect or disconnect the hose while
under pressures greater than 200 bar/3000 psi.
LIMITED WARRANTY AND LIMITATION OF LIABILITY
This Fluke product will be free from defects in material and
workmanship for one year from the date of purchase. This warranty
does not cover fuses, disposable batteries, or damage from
accident, neglect, misuse, alteration, contamination, or abnormal
conditions of operation or handling. Resellers are not authorized to
extend any other warranty on Fluke’s behalf. To obtain service
during the warranty period, contact your nearest Fluke authorized
service center to obtain return authorization information, then send
the product to that Service Center with a description of the problem.
THIS WARRANTY IS YOUR ONLY REMEDY. NO OTHER
WARRANTIES, SUCH AS FITNESS FOR A PARTICULAR
PURPOSE, ARE EXPRESSED OR IMPLIED. FLUKE IS NOT
LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR
CONSEQUENTIAL DAMAGES OR LOSSES, ARISING FROM
ANY CAUSE OR THEORY. Since some states or countries do not
allow the exclusion or limitation of an implied warranty or of
incidental or consequential damages, this limitation of liability may
not apply to you.
Fluke Corporation
P.O. Box 9090
Everett, WA 98206-9090
U.S.A.
Fluke Europe B.V.
P.O. Box 1186
5602 BD Eindhoven
The Netherlands
11/99

Produktspecifikationer

Varumärke: Fluke
Kategori: Pomp
Modell: 700HTH-1

Behöver du hjälp?

Om du behöver hjälp med Fluke 700HTH-1 ställ en fråga nedan och andra användare kommer att svara dig




Pomp Fluke Manualer

Pomp Manualer

Nyaste Pomp Manualer