Programming :
1. To start programming, press key
Prog”, the first program step
flashes.
2. Set the first switching time with key +
or “-
3. Use the ” button to choose between on/off
circuit:
ON and circuit OFF.
ON = work authorization period.
OFF = work banning period.
4. Enter the settings by pressing
Prog(short press).
You must now choose
the days of the week
that the settings apply to.
5. With key and ”, display one after the + -
other each day of the week and select with
key “on/off if the program applies to this
day or not.
Days to which the switching is to be applied
must be visible at the bottom of the display
e.g. 1 2 3 4 5 visible, means switching will
be applied Monday to Friday.
6. Press “Prog” to enter this program step.
7. To adjust the time settings
as well as the assignments to the
days of the week ;
Repeat operation 2 to 6 for further
programmes. (maximum 20)
If no buttons are pressed within 2 min.,
the device switches back to automatic mode
without recording your settings.
8. To record your settings and
return to automatic mode press
Progfor more than 2 seconds.
4
Description:
The programmable light sensitive switch EE171
has two main functions:
• a light sensitive switch comprising:
Override selector switch to allow permanent
setting ON or OFF, auto or test mode.
Lighting range selector.
Potentiometer to set light level.
Indicator to show output switching.
• a programmer to establish the automatic
operating cycle.
The programmer comprises 4 keys:
on/off to choose whether the circuit is on or off
Prog to set the program and scroll program
steps
reset
+ -and to change settings
On the display are indicated :
A. the current time
B.the working status ON (authorization) or
OFF (banning)
C.The days to which the program applies.
(1= Monday, 2 = Tuesday ...............7 = Sunday)
Setting time and day:
Press key + or -.
A continuous pressing on this keys will scroll up or
down minutes, hours and then days.
6E 7524.f
EE171
Operating principle:
The EE171 programmable light sensitive
switch controls light sytems according to
a program set by the user, depending on
natural illumination.
- during the work authorization period,
depending on wether the measured light
level is below or above the required level,
it will be switched on or off.
- during the work banning period, the
contact remains open, whatever the light
level is.
The light sensitive switch includes a built in
time delay which avoid unnecessary swit-
ching due to temporary factors such as car
beams etc...
Lux
T
6:00 8:00 17:00 23:00
ON ON
OFF OFF OFF
11 10
12
N
51 2
L
6
6E0585a
230 V 50 Hz
16A 250V
10 11 12
AC1
test
auto
2000
50
Lux
100
5
12
12
12
12
12
7
7
7
77 8
8
8
88 9
9
9
99
10
10
10
10
10
11
11
11
11
11
6
6
6
66
1
1
1
11 2
2
2
22 3
3
3
33 4
4
4
44 5
5
5
55
127 8 9 10 11
61 2 3 4 5
on/off Prog
+
To check your settings :
In automatic mode :
Press “Prog” repeatedly to display the day, the
time and the circuit status (ON or OFF).
To switch back to automatic mode, press
Progfor more than 2 sec.
To reset the time switch :
Press the “resetbutton, the program will be
cancelled.
Make sure the light sensitive switch is
unplugged before connecting the cell.
§Programmable light
sensitive switch
User instructions
6E 7524.f
Warranty
Technical specification:
Electrical specification
- Voltage rating : 230V ~+10/-15% 50 Hz
- Consumption : 1,5 VA max.
- Output : 1 voltage free changeover contact
Max. breaking capacity :
AC1 16A 250V ~
Incandescent lamp 2000W 230V ~
Halogen lamp 1000W 230V ~
Fluorescent lamp :
uncompensated 1000W 230V~
compensated in series (10μF) 1000W 230V ~
// compensated (15μF) 200W 230V ~
duo 1000W 230V ~
Functional characteristics
- 2 sensitivity ranges 5 to 100 lux
50 to 2000 lux
- weekly cycle
- 8 predefined programs
- program setting : 1 minute increments
- accuracy : ± 6 min./ annum
- operating reserve : lithium battery total of
3 years of supply failure
- on and off delay : 15 to 60 s.
- working temperature :
-30 °C to +60 °C (cell),
-10 °C to +50 °C (Modular device)
- Storage temperature :
- 20 °C to +60 °C
- Protection class (cell) : IP54
- Insulation class (cell) : II
Connection capacity
- modular device : 0,5 to 4 mm2
- cell : 0,75 to 2,5 mm2
Max lenght between cell and modular
device : 50 m
mounting of the cell with 2 screws
Ø 2,5 mm
Permanent overrides
the override selector allows permanent
overrides which have priority on programming
and the measured light level.
permanent override "ON"
permanent override "OFF"
Setting of the working level:
The test position of the override selector
makes easier the setting of the working level,
it removes the ON and OFF delay.
Select the sensitivity range which suits whith
the appliccation (selector ) :
5 to 100 lux (low light level) applica-
tion examples : public lighting, shop
windows, signals....
50 to 2000 lux (high light level) applica-
tion examples : control of shades.
At the appropriate moment of the day, put
the selector in testposition ; turn the
potentiometer up to the switching point
(the indicator lights) ; put the selector back
to position auto”, the normal operating mode
of the device.
Mounting of the cell:
To ensure a good working of the light sensi-
tive switch, the cell must not be influenced by
artificial light or direct solar radiation and has to
be sheltered from dust and humidity.
In case of disconnection of the link between
the cell and the light sensitive switch, the
output of the device will be switched on.
test
auto
test
auto
A warranty period of 24 months is offered on hager products,
from date of manufacture, relating to any material of manufac-
turing defect. If any product is found to be defective it must be
returned via the installer and supplier (wholesaler). The warranty
is withdrawn if :
- after inspection by hager quality control dept the device is
found to have been installed in a manner which is contrary to
IEE wiring regulations and accepted practice within the industry
at the time of installation.
- the procedure for the return of goods has not been followed.
Explanation of defect must be included when returning goods.
GB
L
N
1
10 11 12
2 5 6
Make sure the light sensitive switch is
unplugged before connecting the cell.
www.hager.com2
Descrizione del dispositivo:
L’interruttore crepuscolare programmabile EE171 si
compone di due parti:
• Un interruttore crepuscolare costituito da:
Commutatore per la selezione delle forzature
permanentemente aperte o chiuse, della
modalità automatico o del modo test.
Commutatore per la selezione della gamma di
luminosità.
Potenziometro per la regolazione della soglia di
luminosità.
Spia luminosa per la visualizzazione dello stato
dell’uscita.
• un programmatore per stabilire il ciclo automatico
di funzionamento.
E’ dotato di 4 pulsanti:
on/off per selezionare lo stato dell’uscita
Prog per la programmazione e la visualizzazione
dei passi di programma
reset per l’azzeramento del programmatore
+ -e per lo scorrimento ore e minuti
Sul display sono evidenziate le seguenti indicazioni:
A. Visualizzazione delle ore e minuti attuali.
B.Periodo di autorizzazione (ON), o di divieto (OFF)
di apertura.
C.Giorni ai quali il programma si applica:
(1=lunedì, 2=martedì,.............7=domenica)
Impostazione della data e dell'ora
La regolazione dell’ora avviene tramite pressione
più o meno lunga sul pulsante o “+ -”.
Una pressione lunga evidenzia rapidamente i minuti,
le ore ed i giorni.
6E 7524.f
EE171
Principio di funzionamento:
L’interruttore crepuscolare programmabile EE171
permette di comandare automaticamente
circuiti d’illuminazione secondo un programma
stabilito dall’utente, in funzione della luce
naturale.
- Durante il periodo di chiusura del contatto
del temporizzatore, l’uscita è attiva o meno,
a seconda del livello d’illuminazione misu-
rato dalla fotocellula fotoresistente.
- Senza il consenso del temporizzatore,
l’uscita è inattiva qualunque sia il livello di
luminosità.
Un breve ritardo pre-impostato del contatto,
alla chiusura e all’apertura, permette di evitare
commutazioni intempestive in presenza di
variazioni brutali di luminosità: lampi, fari
d’auto, ecc...
Lux
T
6:00 8:00 17:00 23:00
ON ON
OFF OFF OFF
11 10
12
N
51 2
L
6
6E0585a
230 V 50 Hz
16A 250V
10 11 12
AC1
test
auto
2000
50
Lux
100
5
12
12
12
12
12
7
7
7
77 8
8
8
88 9
9
9
99
10
10
10
10
10
11
11
11
11
11
6
6
6
66
1
1
1
11 2
2
2
22 3
3
3
33 4
4
4
44 5
5
5
55
127 8 9 10 11
61 2 3 4 5
on/off Prog
+
Programmazione:
1. Premere suProg” per
iniziare la programmazione.
Il primo comando lampeggia.
2. Con “ e “ regolare il primo orario di + -
commutazione.
3. Con il pulsante on/off, scegliere lo stato
dei contatti:
ON = abilitato
OFF = disabilitato.
4. Memorizzare tramite il tasto
Prog(breve pressione).
Occorre ora definire i giorni
ai quali applicare questo
comando.
5. Con i pulsanti e “ , fare scorrere i giorni + -
della settimana e selezionare con il pulsante
on/off” se attribuire o meno il comando al
giorno selezionato.
6. Premere suProg” per confermare questo
passo di programma.
7. Per impostare gli orari di
commutazione e i giorni della
settimana successivi,
ripetere le operazioni
da 2 a 6 (massimo 20 passi).
Se non sarà premuto alcun pulsante entro due
minuti, il programmatore tornerà alla modalità
automatico senza tenere conto delle vostre
scelte.
8. Per confermare la programmazione
e passare alla modalità automatico,
premere il pulsante “ entro Prog
2 secondi.
Per rileggere il vostro programma:
In modo automatico:
tramite pressioni successive sul pulsante
Prog”, si visualizzano i vari comandi: orari
di commutazione, stato dei contatti e giorni
scelti.
Per ritornare al funzionamento automatico,
premere il pulsante “ per più di dueProg
secondi.
Per azzerare il programmatore :
Premere il pulsante “ per cancellare il reset
programma.
Al momento del collegamento della foto-
cellula, o prima di qualsiasi intervento su di
essa, interrompere l’alimentazione 230V
dell’interruttore crepuscolare.
Interruttore crepuscolare
programmabile
Istruzioni d’uso

Produktspecifikationer

Varumärke: Hager
Kategori: Växla
Modell: EE171

Behöver du hjälp?

Om du behöver hjälp med Hager EE171 ställ en fråga nedan och andra användare kommer att svara dig




Växla Hager Manualer

Hager

Hager SBB225 Bruksanvisning

21 September 2024
Hager

Hager JAB406B Bruksanvisning

18 September 2024
Hager

Hager JAB403B Bruksanvisning

17 September 2024
Hager

Hager SB432PV Bruksanvisning

17 September 2024
Hager

Hager HA358 Bruksanvisning

17 September 2024
Hager

Hager JAB402B Bruksanvisning

17 September 2024
Hager

Hager EGN400AU Bruksanvisning

16 September 2024
Hager

Hager TXA610B Bruksanvisning

7 September 2024
Hager

Hager SR00T Bruksanvisning

3 September 2024

Växla Manualer

Nyaste Växla Manualer