Hikvision DS-K3B801BX-L Bruksanvisning

Läs nedan 📖 manual på svenska för Hikvision DS-K3B801BX-L (2 sidor) i kategorin Tillträdeskontrollsystem. Denna guide var användbar för 3 personer och betygsatt med 4.5 stjärnor i genomsnitt av 2 användare

Sida 1/2
DS-K3B801BX Series
Swing Barrier
Quick Start Guide
UD31569B
©2022 Hangzhou Hikvision Digital Technology Co., Ltd. All rights reserved.
About this Manual
The Manual includes instructions for using and managing the Product. Pictures, charts,
images and all other information hereinafter are for description and explanation only.
The information contained in the Manual is subject to change, without notice, due to
firmware updates or other reasons. Please find the latest version of this Manual at the
Hikvision website (https://www.hikvision.com/).
Please use this Manual with the guidance and assistance of professionals trained in
supporting the Product.
Trademarks
and other Hikvision’s trademarks and logos are the properties of Hikvision in
various jurisdictions.
Other trademarks and logos mentioned are the properties of their respective owners.
Disclaimer
TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, THIS MANUAL AND THE
PRODUCT DESCRIBED, WITH ITS HARDWARE, SOFTWARE AND FIRMWARE, ARE PROVIDED
AS IS” AND WITH ALL FAULTS AND ERRORS”. HIKVISION MAKES NO WARRANTIES,
EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION, MERCHANTABILITY,
SATISFACTORY QUALITY, OR FITNESS FOR A PARTICULAR PURPOSE. THE USE OF THE
PRODUCT BY YOU IS AT YOUR OWN RISK. IN NO EVENT WILL HIKVISION BE LIABLE TO YOU
FOR ANY SPECIAL, CONSEQUENTIAL, INCIDENTAL, OR INDIRECT DAMAGES, INCLUDING,
AMONG OTHERS, DAMAGES FOR LOSS OF BUSINESS PROFITS, BUSINESS INTERRUPTION,
OR LOSS OF DATA, CORRUPTION OF SYSTEMS, OR LOSS OF DOCUMENTATION, WHETHER
BASED ON BREACH OF CONTRACT, TORT (INCLUDING NEGLIGENCE), PRODUCT LIABILITY,
OR OTHERWISE, IN CONNECTION WITH THE USE OF THE PRODUCT, EVEN IF HIKVISION
HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES OR LOSS.
YOU ACKNOWLEDGE THAT THE NATURE OF THE INTERNET PROVIDES FOR INHERENT
SECURITY RISKS, AND HIKVISION SHALL NOT TAKE ANY RESPONSIBILITIES FOR ABNORMAL
OPERATION, PRIVACY LEAKAGE OR OTHER DAMAGES RESULTING FROM CYBER-ATTACK,
HACKER ATTACK, VIRUS INFECTION, OR OTHER INTERNET SECURITY RISKS; HOWEVER,
HIKVISION WILL PROVIDE TIMELY TECHNICAL SUPPORT IF REQUIRED.
YOU AGREE TO USE THIS PRODUCT IN COMPLIANCE WITH ALL APPLICABLE LAWS, AND
YOU ARE SOLELY RESPONSIBLE FOR ENSURING THAT YOUR USE CONFORMS TO THE
APPLICABLE LAW. ESPECIALLY, YOU ARE RESPONSIBLE, FOR USING THIS PRODUCT IN A
MANNER THAT DOES NOT INFRINGE ON THE RIGHTS OF THIRD PARTIES, INCLUDING
WITHOUT LIMITATION, RIGHTS OF PUBLICITY, INTELLECTUAL PROPERTY RIGHTS, OR DATA
PROTECTION AND OTHER PRIVACY RIGHTS. YOU SHALL NOT USE THIS PRODUCT FOR ANY
PROHIBITED END-USES, INCLUDING THE DEVELOPMENT OR PRODUCTION OF WEAPONS
OF MASS DESTRUCTION, THE DEVELOPMENT OR PRODUCTION OF CHEMICAL OR
BIOLOGICAL WEAPONS, ANY ACTIVITIES IN THE CONTEXT RELATED TO ANY NUCLEAR
EXPLOSIVE OR UNSAFE NUCLEAR FUEL-CYCLE, OR IN SUPPORT OF HUMAN RIGHTS
ABUSES.
IN THE EVENT OF ANY CONFLICTS BETWEEN THIS MANUAL AND THE APPLICABLE LAW,
THE LATTER PREVAILS.
Data Protection
During the use of device, personal data will be collected, stored and processed. To
protect data, the development of Hikvision devices incorporates privacy by design
principles. For example, for device with facial recognition features, biometrics data is
stored in your device with encryption method; for fingerprint device, only fingerprint
template will be saved, which is impossible to reconstruct a fingerprint image.
As data controller, you are advised to collect, store, process and transfer data in
accordance with the applicable data protection laws and regulations, including without
limitation, conducting security controls to safeguard personal data, such as,
implementing reasonable administrative and physical security controls, conduct periodic
reviews and assessments of the effectiveness of your security controls.
1System Wiring 2Installation
3Wiring
1. Draw a central line on the installation
surface of the left or right pedestal.
2. Draw other parallel lines for installing
the other pedestals.
The distance between the nearest
two lines is L + 190 mm. L represents
the lane width.
3. Slot on the installation surface and dig
installation holes according to the hole
position. Put 8 expansion bolts of
M12*120 for each pedestal.
4. Bury cables. Each lane buries 1 high
voltage cable and 1 low voltage cable. For
details, see the system wiring diagram.
High voltage: AC power input
Low voltage: interconnecting cables
The supplied interconnecting cables is 5.5 m
in length.
The suggested inner diameter of the low
voltage conduit is larger than 30 mm.
If you want to bury both of the AC power cord
and the low voltage cable, the two cables
should be in separated conduits to avoid
interference.
If more peripherals are required to connect,
you should increase the conduit diameter or
bury another conduit for the external cables.
The external AC power cord should be
double-insulated.
The network cable must be CAT5e or the
network cable has better performance.
Steps:
Steps:
1. Prepare installation tools and clean the installation base.
2. Disassemble the pedestal and keep the disassembled components and screws.
3. Drill holes on the ground according to the installation holes on the pedestals and
insert the expansion sleeves.
4. According to the entrance and exit marks on the pedestals, move the pedestals to
the corresponded positions.
5. Secure each pedestal with 8 nuts.
6. After installation, assemble the components and screws back to the pedestal.
Make sure the device is installed on flat surface.
Make sure the device is powered off during installation and other operations.
The installation tools are put inside the package of the pedestal.
If the installation area is close to the wall, make
sure the distance between the pedestal and the
wall should be more than 10 mm, or you might
cause damage to the device or cannot open the
pedestal's top panel.
Dimension
1
1
2
2
Access Control Board
Reserved
Reserved
Loudspeaker
Interface
Interconnecting
Interface
(For Sub Extended
Interface Board)
Network
Interface
SOC Serial Port
MCU Serial Port Reserved
DIP Switch
Reserved Main Lane
Control Board
Interface
Extended
Interface
12 VDC Output
RS-485 Interface
24 VDC Input
SOC
WIFI
LAN
SWITCH
BUS1
TO
MAIN
LANE
CONTROL
BOARD
USB
GND
12VOUT
RS485C-
RS485A-
RS485C+
RS485A+
24VIN
GND
MIC
SPK
MCU
BUS4
BUS3
MAIN
CROSS
DEBUG1
DEBUG2
Reset Button
SOC and MCU serial port are for debugging and
maintenance use only.
Hold the reset button for 5 s, the device will
beep for 3 s and start restoring to factory
settings.
The DIP switch is for study mode settings and
keyfob pairing. Refer to the user manual for
details.
RS-485A corresponds to UART 5 on web and is
for QR code scanner connection at entrance by
default; RS-485C corresponds to UART 7 on web
and is for card reader connection at entrance by
default.
RS-232A is on the extended interface of BUS3.
RS-232A corresponds to UART 1 on web and is
for fingerprint module connection at entrance
by default.
Entrance
Main Lane Control Board
Main and Sub
Lane Control
Board
Sub Lane
Control Board
Power Supply
Power Supply
Access Control Board
Card Reader Board (Optional)
Card Reader Board (Optional)
Access Control Board
Main Switch
Main Switch
Main Extended Interface Board
Main Extended Interface Board
Sub Extended Interface Board
Sub Extended
Interface Board
QR Code
Scanner
(Optional)
Fingerprint
Module
(Optional)
Secure each pedestal with 8
expansion bolts of M12*150.
1400 mm
500 mm 500 mm
90 mm
15 mm
L + 190 mm
L
High Voltage
Low Voltage Low Voltage
Main Switch
Main Switch
Access Control Board Access Control Board
Main Extended
Interface Board
Main Extended
Interface Board
Sub Extended
Interface Board
Sub Extended
Interface Board
Sub Lane
Control Board
Main Lane
Control Board
Main Lane
Control Board
Sub Lane
Control Board
Entrance
The diagram is for reference. Dimensions may differ in models.
10 mm 10 mm
175 mm 190 mm 1500 mm
1010 mm
Lane Width
Barrier
Height
Main Lane Control Board
Sub Lane Control Board
Scan the QR code to view the face recognition
installation and wiring video.
Regulatory Information
FCC Information
Please take attention that changes or modification not expressly approved by the party
responsible for compliance could void the user’s authority to operate the equipment.
FCC compliance: This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful interference to
radio communications. However, there is no guarantee that interference will not occur in
a particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the following
measures:
—Reorient or relocate the receiving antenna.
—Increase the separation between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
—Consult the dealer or an experienced radio/TV technician for help.
This equipment should be installed and operated with a minimum distance 20cm between
the radiator and your body.
FCC Conditions
This device complies with part 15 of the FCC Rules. Operation is subject to the following
two conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including interference that may
cause undesired operation.
This product and - if applicable - the supplied accessories too are
marked with "CE" and comply therefore with the applicable
harmonized European standards listed under the RE Directive
2014/53/EU, the EMC Directive 2014/30/EU, the RoHS Directive
2011/65/EU.
2006/66/EC (battery directive): This product contains a battery
that cannot be disposed of as unsorted municipal waste in the
European Union. See the product documentation for specific
battery information. The battery is marked with this symbol, which
may include lettering to indicate cadmium (Cd), lead (Pb), or
mercury (Hg). For proper recycling, return the battery to your
supplier or to a designated collection point. For more information
see: www.recyclethis.info
2012/19/EU (WEEE directive): Products marked with this symbol
cannot be disposed of as unsorted municipal waste in the
European Union. For proper recycling, return this product to your
local supplier upon the purchase of equivalent new equipment, or
dispose of it at designated collection points. For more information
see: www.recyclethis.info
Warning
In the use of the product, you must be in strict compliance
with the electrical safety regulations of the nation and
region.
Do not connect several devices to one power adapter as
adapter overload may cause over-heat or fire hazard.
If smoke, odors or noise rise from the device, turn off the
power at once and unplug the power cable, and then
please contact the service center.
The socket-outlet shall be installed near the equipment
and shall be easily accessible.
1. Do not ingest battery. Chemical burn hazard!
2. This product contains a coin/button cell battery. If the
coin/button cell battery is swallowed, it can cause severe
internal burns in just 2 hours and can lead to death.
3. Keep new and used batteries away from children.
4. If the battery compartment does not close securely,
stop using the product and keep it away from children.
5. If you think batteries might have been swallowed or
placed inside any part of the body, seek immediate
medical attention.
6. CAUTION: Risk of explosion if the battery is replaced by
an incorrect type.
7. Improper replacement of the battery with an incorrect
type may defeat a safeguard (for example, in the case of
some lithium battery types).
8. Do not dispose of the battery into fire or a hot oven, or
mechanically crush or cut the battery, which may result in
an explosion.
9. Do not leave the battery in an extremely high
temperature surrounding environment, which may result
in an explosion or the leakage of flammable liquid or gas.
10. Do not subject the battery to extremely low air
pressure, which may result in an explosion or the leakage
of flammable liquid or gas.
11. Dispose of used batteries according to the instructions
Caution
Do not drop the device or subject it to physical shock, and
do not expose it to high electromagnetism radiation. Avoid
the equipment installation on vibrations surface or places
subject to shock (ignorance can cause equipment
damage).
Do not place the device in extremely hot (refer to the
specification of the device for the detailed operating
temperature), cold, dusty or damp locations, and do not
expose it to high electromagnetic radiation.
Exposing the equipment to direct sun light, low ventilation
or heat source such as heater or radiator is forbidden
(ignorance can cause fire danger). The device cover for
indoor use shall be kept from rain and moisture.
Exposing the equipment to direct sun light, low ventilation
or heat source such as heater or radiator is forbidden
(ignorance can cause fire danger).
Please use a soft and dry cloth when clean inside and
outside surfaces of the device cover, do not use alkaline
detergents.
Biometric recognition products are not 100% applicable to
anti-spoofing environments. If you require a higher
security level, use multiple authentication modes.
The serial port of the equipment is used for debugging
only.
Wall Mounting: Install the equipment according to the
instructions in this manual. To prevent injury, this
equipment must be securely attached to the floor/wall in
accordance with the installation instructions.
Improper use or replacement of the battery may result in
hazard of explosion. Replace with the same or equivalent
type only. Dispose of used batteries according to the
instructions provided by the battery manufacturer.
This bracket is intended for use only with equipped
devices. Use with other equipment may result in instability
causing injury.
This equipment is for use only with equipped bracket. Use
with other (carts, stands, or carriers) may result in
instability causing injury.
Safety Instructions
4Wiring Diagram
• You will need to prepare the 14AWG power cable to connect the AC power input to power supply.
The supplied 2 interconnecting cables need connecting on-site:
1. Communication cable for connection between main lane control board and sub lane control board. The cable is 5.5 m in length and put inside the package of the right/middle pedestal.
2. CAT5e Communication cable. The cable is 5.5 m in length and put inside the package of the right/middle pedestal.
• ① and ② refer to the two sides of a same board.
• Face recognition terminals can be connected via RS-485 interface on the access control board (for entrance) or sub extended interface board (for exit).
Reserved
Reserved
12 VDC
Power Output
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Wiegand/Exit
Button Interface
Communication
Interface
(For Main Lane
Control Board)
RS-485B corresponds to UART 6 on web and is for QR code scanner connection
at exit by default; RS-485D corresponds to UART 4 on web and is for card
reader connection at exit by default; RS-232B corresponds to UART 2 on web,
RS-232C corresponds to UART 3 on web.
Access Control
Board Interface
Card Reader Board (Optional)
Main Extended Interface Board
Sub Extended Interface Board
125 K
Antenna
Debugging Port
DIP Switch
Reserved
13.56 M
Antenna
485-
485+
GND
12 VDC
Sub-1G
RS485B+
RS485D+
RS485B-
RS485D-
RS232BT
RS232CT
12VOUT
RS232BR
RS232CR
GND
LED1
LED2
SPK
BZ
W1
W0
GND
BTN
GND
GND
5VOUT
BUS2
BUS1
TO
SUB
SUB
CROSS
1
1
2
2
485/232
Terminals
12 VDC
Power Output
Wiegand/Exit
Button Interface
5 VDC
Power Output
Communication
Interface
(For Sub Lane
Control Board)
1
1
2
2
Reserved Reserved
Interconnecting
Interface
(For Access
Control Board)
Reserved
Reserved
Reserved
Sub-1G
RS485B+
RS485D+
RS485B-
RS485D-
RS232BT
RS232CT
12VOUT
RS232BR
RS232CR
GND
LED1
LED2
SPK
BZ
W1
W0
GND
BTN
GND
GND
5VOUT
BUS2
BUS1
TO
SUB
SUB
CROSS
Scan the QR code to view the user manual.
BUS2
1
1
2
2
485-
485B
13.56 M Antenna
125 K Antenna
485+
485A
GND
GND
VCC
12V
D1
D0
NC1
NC3
NC2
NC4
COM1
COM3
COM2
COM4
NO1
NO3
NO2
NO4
GND
GND
GND
GND
GND
GND
GND
5V
5V
24V
RS232A_RX
RS232A_TX
RS232A_TX
RS232A_RX
CASE2_OUT
XF_OUT
CASE1_OUT
BUTTON1_OUT
BUTTON2_OUT
GND
12VOUT
RS485C-
RS485A-
RS485C+
RS485A+
BUS1
TO
MAIN LANE
CONTROL
BOARD
Access Control Board
Main Extended Interface Board
1
1
2
2
Sub Extended Interface Board
Fingerprint Module
Fingerprint Module
(Exit)
QR Code Scanner
(Exit)
Card Reader Board
(Entrance)
QR Code Scanner
(Entrance)
BZ
W0
W1
GND
BTN
GND
GND
5VOUT
BZ
W0
W1
GND
BTN
GND
SPK
BUS3
MAIN
CROSS
GND
485B
5V
485A
RS232_TX
VCC
D1
D0
RS232_RX
GND
Card Reader
Board (Exit)
485-
13.56 M Antenna
125 K Antenna
485+
GND
12V
RS485B+
RS485D+
RS485B-
RS485D-
RS232BT/RS232B+
RS232BR/RS232B-
12VOUT
GND
Interconnecting
Interface
Lane Communication
Interface
Sub Lane Control Board
Main Lane Control Board
Supercapacitor
CAP
GND
Interconnecting
Interface
Lane Communication
Interface
Interconnecting Cable
Interconnecting Cable
Supercapacitor
Interface
Main Lane
1
1
2
2
Sub Lane
Third Party
Card Reader Third Party
Card Reader
Loudspeaker
BUS2
Supercapacitor
CAP
GND

Produktspecifikationer

Varumärke: Hikvision
Kategori: Tillträdeskontrollsystem
Modell: DS-K3B801BX-L

Behöver du hjälp?

Om du behöver hjälp med Hikvision DS-K3B801BX-L ställ en fråga nedan och andra användare kommer att svara dig




Tillträdeskontrollsystem Hikvision Manualer

Tillträdeskontrollsystem Manualer

Nyaste Tillträdeskontrollsystem Manualer