Infresco Dimmer 6Kw Bruksanvisning
Infresco
Temperaturkontroll
Dimmer 6Kw
Läs nedan 📖 manual på svenska för Infresco Dimmer 6Kw (2 sidor) i kategorin Temperaturkontroll. Denna guide var användbar för 5 personer och betygsatt med 4.5 stjärnor i genomsnitt av 2 användare
Sida 1/2
Specificati
o
Infresco M
a
Mains Volt
a
Max load a
t
Power Con
s
PIR Set Ti
m
Temperatu
r
Factory Se
t
IP Rating
Gland Dia
m
2 Lamp Ins
t
Operating
T
IP Rating
Max Unit O
p
Dimension
s
PIR Move
m
Operating
V
Direction
Detect
Outdoor T
e
Dimension
s
WARNING
It is import
a
It is recom
m
heat
dissipation
It is recom
m
reference t
o
qualified/tr
a
These regu
Internation
a
o
ns
a
in Unit
a
ge
t
20°C ambient
s
umption
m
e Period
r
e Set point
t
Temperature trip poi
n
m
eter
t
allation
T
emperature
p
erating Temperature
s
m
ent Sensor (option
a
V
oltage
e
mperature Sensor
(
s
a
nt that the Infresco I
R
m
ended that the heats
m
ended that installatio
o
the current edition o
f
a
ined personnel.
lations contain import
a
a
l Standards refer to I.
230
V
6 kW
50m
A
5 Mi
n
5°C t
o
n
t 20°C
65
Max
C
Must
-20°
C
IP65
65°C
W=2
8
‘D’ in
c
a
l)
12V
d
90°A
d
18 M
e
(
optional)
W=1
1
R
is not mounted direc
t
ink be spaced off any
n and maintenance o
f
f
the I.E.E. wiring reg
u
a
nt requirements reg
a
E.C/ directive IEC95
0
V
ac +/-10% 50 Hz
A
n
utes
o
25°C
C
able Entry 2.5mm²
be fitted in Parallel
C
to 30°C
8
0mm D=200mm H=
8
c
lusive of Glands
d
c
d
justable
e
tres
1
5mm D=110mm H=
5
t
ly to any flammable
m
the mounting wall usi
f
this equipment shou
l
u
lations (BS7671) by
s
a
rding safety of electri
c
0
).
8
0mm
5
5mm
m
aterial i.e. wood.
ng pillars to aid in
d be done with
s
uitably
c
al equipment (for
INFRE
S
S
CO
Installa
M
6kW
tion & U
s
M
anual
IR Cont
r
s
ers’
r
ol
INTRODUCTION
The Infresco has been designed specifically to work with Infra Red Heaters, with a rating of 4kW it
will allow you to control a variety of heating and lighting solution.
The Infresco has a 1 to 10 step setting allowing you to find the optimum comfort setting in you
specific area. With energy saving a major factor in the design brief, once the Infresco is switched
on it will automatically manage the heating system. With a built in temperature sensor only
allowing the unit to switch on when required and a PIR that will detects a requirement for the
heater to switch on only when needed. An optional remote control allows for the unit to be fitted
out of the way so safety is paramount. The Infresco has a built in soft start function which will add
up to an additional 30% life to your heater lamp.
APPLICATIONS
Any application were high inrush current is an issue or control is required. Typical use is for Infra Red
Heating lamps, Garden lighting
FEATURES
Soft Start – up to 30% extended life of Lamp
Variable Control – Ability to find comfort level
Simple Installation – Ability to plug directly in 13A Plug with up to 3kW load
Energy Saving – Automated system. (Only heat when required)
Temperature Monitoring – If ambient temperature is above preset the Infresco unit remains
switched off
SAFETY FIRST
Please read these instructions before installing and operating this product. (See warning for
additional information).
Installation
The ideal site for the PIR to be mounted is approximately 2.5 + Meters of the floor. Ceiling
mounting is preferred but not essential
The PIR must not be mounted.
• Directly in line of the lamps output
• Highly reflective surfaces
• Radiators or other thermostatically controlled heaters
• Open door ways with people walking past
Commissioning
NOTE: On switch on the PIR takes 60 seconds to set before detection takes place
NOTE: The PIR continues to monitor the area and will reset to the set time every time it detects
movement.
Before testing ensure the wiring is correct. The temperature trip point has already been preset at
the factory. The timer is preset to 5 minutes.
The expected detection area can now be “walked tested” using the diagram shown in mind. The
area should be crossed in various directions to ensure coverage is as expected.
Display Features
Display shows ‘t’ The Infresco is turned OFF as the ambient temperature
is above the trip level set by TEMP. SET.
Display shows ‘F’ The Infresco is set to FULL output.
Display decimal point pulses The PIR input is waiting to be enabled i.e. no movement.
Display decimal point fully on The Infresco is in Standby mode pressing the remote
control POWER button will toggle the power ON and OFF.
You can check the remote control is transmitting by observing the decimal point flashing rapidly.
UijthovenInfrarood
Nijverheidstraat31
4261TKWijkenAalburgTheNetherlands
Phone:0031416532724
Fax:0031416532719
E‐mail:info@uithoven.nl
Web:www.terrastopper.nl
Produktspecifikationer
Varumärke: | Infresco |
Kategori: | Temperaturkontroll |
Modell: | Dimmer 6Kw |
Behöver du hjälp?
Om du behöver hjälp med Infresco Dimmer 6Kw ställ en fråga nedan och andra användare kommer att svara dig
Temperaturkontroll Infresco Manualer
10 September 2024
Temperaturkontroll Manualer
- Temperaturkontroll Bosch
- Temperaturkontroll Honeywell
- Temperaturkontroll Junkers
- Temperaturkontroll Nefit
- Temperaturkontroll Remeha
- Temperaturkontroll Ventus
- Temperaturkontroll Barbecook
- Temperaturkontroll Bulex
- Temperaturkontroll ICY
- Temperaturkontroll Sentiotec
- Temperaturkontroll Thermomax
Nyaste Temperaturkontroll Manualer
18 Oktober 2024
5 Oktober 2024
21 September 2024
15 September 2024
Barbecook Digitale thermometer Temperatuurregeling Bruksanvisning
15 September 2024
29 Augusti 2024
28 Augusti 2024
22 Augusti 2024
22 Augusti 2024
20 Augusti 2024