JANDY JCP07-3AT-N Bruksanvisning
Läs nedan 📖 manual på svenska för JANDY JCP07-3AT-N (108 sidor) i kategorin Pomp. Denna guide var användbar för 9 personer och betygsatt med 4.5 stjärnor i genomsnitt av 2 användare
Sida 1/108
WARNING
FOR YOUR SAFETY - This product must be installed and serviced by a contractor who is licensed and
qualified in pool equipment by the jurisdiction in which the product will be installed where such state or
local requirements exist. The maintainer must be a professional with sufficient experience in pool equipment
installation and maintenance so that all of the instructions in this manual can be followed exactly. Before
installing this product, read and follow all warning notices and instructions that accompany this product.
Failure to follow warning notices and instructions may result in property damage, personal injury, or death.
Improper installation and/or operation may void the warranty.
Improper installation and/or operation can create unwanted electrical hazard which can
cause serious injury, property damage, or death.
ATTENTION INSTALLER - This manual contains important information about the installation,
operation and safe use of this product. This information should be given to the owner/
operator of this equipment.
INSTALLATION AND
OPERATION MANUAL
JCP Series High Performance
Commercial Pumps
JCP05-1CT-S
JCP07-1BD-S
JCP05-3AT-S
JCP07-3AT-S
JCP10-3AT-S
JCP15-3AT-S
JCP05-1CT-N
JCP07-1BD-N
JCP05-3AT-N
JCP07-3AT-N
JCP10-3AT-N
JCP15-3AT-N
H0679300_REV C
ENGLISH | FRAN AIS | ESPAÑOLÇ
Page 2
Jandy® JCP Series High Performance Commercial Pumps | Installation & Operation Manual
ENGLISH
Table of Contents
EQUIPMENT INFORMATION RECORD
DATE OF INSTALLATION
INSTALLER INFORMATION
INITIAL PRESSURE GAUGE READING (WITH CLEAR FILTER)
PUMP MODEL HORSEPOWER
NOTES:
Section 1. Important Safety Instructions 3 .......
1.1 Safety Instructions 3 ..............................................
1.2 Pool Pump Suction Entrapment Prevention
Guidelines 5 ..........................................................
Section 2. General Description 6 .......................
2.1 JCP Series Pump Operations............................. 6
Section 3. Mechanical and Electrical
Installation and Pressure
Testing 7 .............................................
3.1 Pump Handling 7 ...................................................
3.2 Pump Location 7 ...................................................
3.3 Mechanical Installation 8 .......................................
3.4 Electrical Installation 8 ...........................................
3.5 Strainer Pot Service 10 .........................................
3.6 Pressure Testing, Strainer Pot ...........................11
Section 4. Jandy JCP Pump Operation 13 ........
4.1 Priming ............................................................. 13
Section 5. Maintenance and Storage 14 ............
5.1 Maintenance ..................................................... 14
5.2 Storage ............................................................. 14
Section 6. Servicing 15 .......................................
6.1 Required Tools.................................................. 15
6.2 Replacement Parts 15 ...........................................
6.3 Alternate Parts 15 ..................................................
6.4 Pump Disassembly 15 ...........................................
6.5 Pump Assembly ................................................ 17
Section 7. Troubleshooting and Repair 18 ........
Section 8. Replacement Parts List 21 ................
8.1 JCP R-Kit List 24 ...................................................
Section 9. Product Dimensions 28 .....................
Section 10. Product Specications ................. 30
10.1 Specications ................................................... 30
Section 11. Technical Data 31 ..............................
Page 3
Jandy® JCP Series High Performance Commercial Pumps | Installation & Operation Manual
WARNING
RISK OF SUCTION ENTRAPMENT HAZARD, WHICH, IF NOT AVOIDED, CAN RESULT IN SERIOUS INJURY
OR DEATH. Do not block pump suction, as this can cause severe injury or death. Do not use this pump for
wading pools, shallow pools, or spas containing bottom drains, unless the pump is connected to at least two
(2) functioning suction outlets. Suction outlet (drain) assemblies and their covers must be certified to the latest
published edition of ANSI®/ASME® A112.19.8, or its successor standard, ANSI/APSP-16.
WARNING
To reduce the risk of injury, do not permit children and/or people with reduced physical, sensory or mental
capabilities or lack of experience to use this product.
WARNING
To reduce the risk of property damage or injury, do not attempt to change the valve position with the pump running.
WARNING
Jandy pumps are powered by a high voltage electric motor and must be installed by a licensed or certified
electrician or a qualified swimming pool service technician.
WARNING
Due to the potential risk of fire, electric shock, or injuries to persons, Jandy pumps must be installed in accordance
with the National Electrical Code® (NEC®), all local electrical and safety codes, and the Occupational Safety
and Health Act (OSHA). Copies of the NEC may be ordered from the National Fire Protection Association, 1
Batterymarch Park, Quincy, MA 02169, or from your local government inspection agency.
WARNING
RISK OF ELECTRIC SHOCK, FIRE, PERSONAL INJURY, OR DEATH. (For all permanently installed units
intended for use on 15 or 20 ampere, 120 through 240 volt, single phase branch circuits). Connect only to a
branch circuit that is protected by a ground-fault circuit-interrupter protection for personnel (GFCI). Contact a
qualified electrician if you cannot verify that the circuit is protected by a GFCI. A GFCI should be provided by the
installer and should be tested on a routine basis. To test the GFCI, push the test button. The GFCI should interrupt
power. Push the reset button. Power should be restored. If the GFCI fails to operate in this manner, the GFCI
is defective. If the GFCI interrupts power to the pump without the test button being pushed, a ground current is
flowing, indicating the possibility of electrical shock. Do not use the device. Disconnect the device and have the
problem corrected by a qualified service representative before using.
WARNING
Incorrectly installed equipment may fail, causing severe injury, property damage or death.
ENGLISH
Section 1. Important Safety Instructions
READ AND FOLLOW ALL INSTRUCTIONS
1.1 Safety Instructions
All electrical work must be performed by a licensed electrician and conform to all national, state, and local codes.
When installing and using this electrical equipment, basic safety precautions should always be followed, including the
following:
Produktspecifikationer
Varumärke: | JANDY |
Kategori: | Pomp |
Modell: | JCP07-3AT-N |
Behöver du hjälp?
Om du behöver hjälp med JANDY JCP07-3AT-N ställ en fråga nedan och andra användare kommer att svara dig
Pomp JANDY Manualer
27 Oktober 2024
9 September 2024
7 September 2024
7 September 2024
Pomp Manualer
- Pomp Nefit
- Pomp Vaillant
- Pomp Al-ko
- Pomp Bartscher
- Pomp Eurom
- Pomp Ozito
- Pomp Gude
- Pomp Silvercrest
- Pomp Bestway
- Pomp Vonroc
- Pomp Crivit
- Pomp Hyundai
- Pomp Ryobi
- Pomp Sicce
- Pomp Outwell
- Pomp Metabo
- Pomp Worx
- Pomp Tacklife
- Pomp Hazet
- Pomp Einhell
- Pomp Ultimate Speed
- Pomp SKS
- Pomp Gardena
- Pomp Hayward
- Pomp Eheim
- Pomp Nibe
- Pomp Husqvarna
- Pomp Oase
- Pomp Biltema
- Pomp Powerplus
- Pomp Sanibroyeur
- Pomp Danfoss
- Pomp Michelin
- Pomp Zodiac
- Pomp Powerfix
- Pomp Topeak
- Pomp Hozelock
- Pomp Lezyne
- Pomp Fluke
- Pomp For_Q
- Pomp Simpson
- Pomp Fieldmann
- Pomp Fluval
- Pomp Fuxtec
- Pomp Astralpool
- Pomp Abac
- Pomp Waldbeck
- Pomp Coleman
- Pomp Maruyama
- Pomp Jabsco
- Pomp Toolcraft
- Pomp Pontec
- Pomp ESPA
- Pomp Osram
- Pomp Pedrollo
- Pomp Park Tool
- Pomp Vivaria
- Pomp Plantiflor
- Pomp Little Giant
- Pomp Panduit
- Pomp Anova
- Pomp DAB
- Pomp Wayne
- Pomp T.I.P.
- Pomp Neptun
- Pomp Elpumps
- Pomp Lifan
- Pomp Enermax
- Pomp Liberty Pumps
- Pomp BluGarda
- Pomp Alpha Tools
- Pomp Grundfos
- Pomp Eco-Flo
- Pomp SHURflo
- Pomp EvoHeat
- Pomp MSW
- Pomp OKAY
- Pomp FIAP
- Pomp Barwig
- Pomp Ribimex
- Pomp Ebara
- Pomp Perlick
- Pomp Basement Watchdog
- Pomp Ergotools Pattfield
- Pomp Zéfal
- Pomp Zehnder Pumpen
- Pomp Comet
- Pomp SANDPIPER
- Pomp Heissner
- Pomp Blackburn
- Pomp OSIP
- Pomp Franklin Electric
Nyaste Pomp Manualer
26 Oktober 2024
26 Oktober 2024
26 Oktober 2024
16 Oktober 2024
15 Oktober 2024
15 Oktober 2024
15 Oktober 2024
15 Oktober 2024
15 Oktober 2024
12 Oktober 2024