King WR120-B-KIT Bruksanvisning
Läs nedan 📖 manual på svenska för King WR120-B-KIT (4 sidor) i kategorin Termostat. Denna guide var användbar för 2 personer och betygsatt med 4.5 stjärnor i genomsnitt av 2 användare
Sida 1/4

Page 1
This thermostat is designed to reinforce positive energy habits while limiting landlord energy expenses. For use on 120 Volt AC and a total of 16 Amps
load inductive Continuous.
Check the voltage to make sure you have the right thermostat for your heater voltage. A 1-pole or single-wide breaker indicates a 12 Volt circuit.
Be safe and smart! Electricity can cause severe injury or death if not treated with respect and caution.
This thermostat will provide years of comfort control for your family in use with small fan driven electric heaters, baseboards, radiant ceiling, wall panel
heaters, cove heaters or any line voltage resistance heating systems that do not have an electric motor over 1/3 hp.
OPERATION:
The is a precision electronic thermostat and uses a very sensitive thermistor near the bottom to sense room air
temperature, sending the information on the microprocessor. As the temperature drops, the information sent will indicate if heat is needed.
This saves energy and provides the best temperature control of an area.
The thermostat has an extra contact terminal block for remote set back to 40°F/5°C. Intended for window or door open
contacts. The 40°F/5°C temperature is a fixed setting and not adjustable. The maximum operating temperature is stopped at 74°F/23°C, helping to
change human behaviors that increase energy costs.
INSTALLATION:
This line voltage device should be installed and serviced by a qualified electrician. The thermostat has been designed to mount to a standard
2” x 4” elctrical outlet box. Leveling of the thermostat is not required. #6-32 Phillips head mounting screws are provided.
Mount the thermostat in an open area about 5 feet above the floor, avoiding outside walls as they are too cold and will inhibit the thermostats
performance. A general rule of thumb is to place the thermostat above the wall switch for that room. This works well for most bedrooms, making
it very convenient to turn the heat lower upon leaving. Avoid mounting the thermostat where there may be plumbing pipes in the wall or placing
a lamp or TV too close to the thermostat. Heat from such items negatively affect thethermostats performance.
SPECIFICATIONS:
Temperature range: 40°F/5°C to 74°F/23°C
Temperature Default: Your set point 60°F/16°C
to 40°F/5°C
Display Format: Liquid Crystal Display (LCD)
Display size: Large Format
Sample Rate: Every 60 seconds
Heat indicator: LCD “heater on”
Window Contacts OPEN. (LCD) OPN
Relay Rating: 16 Amps inductive or resistive
Accuracy: ± 0.9°F/±0.5°C
Maximum Amps: 16 inductive continuos
Maximum Watts: 1875 @ 120V
3328 @ 208V
3840 @ 240V
Total inductive motor load combined can not exceed
16 amps
Minimum Watts:0
Power Supply Rated 208/240 VAC
Operating Range 200 to 250 VAC

Page 2
SPECIFICATIONS:
Temperature range: 40°F/5°C to 74°F/23°C
Temperature Default: Your set point 60°F/16°C
to 40°F/5°C
Display Format: Liquid Crystal Display (LCD)
Display size: Large Format
Sample Rate: Every 60 seconds
Heat indicator: LCD “heater on”
Window Contacts OPEN. (LCD) OPN
Relay Rating: 16 Amps inductive or resistive
Accuracy: ± 0.9°F/±0.5°C
Maximum Amps: 16 inductive continuos
Maximum Watts: 1875 @ 120V
3328 @ 208V
3840 @ 240V
Total inductive motor load combined can not exceed
16 amps
Minimum Watts:0
Power Supply Rated 208/240 VAC
Operating Range 200 to 250 VAC
8. Turn ON power. Test by increasing set point to higher than current room temperature by tapping the UP arrow button. You will hear a small click and
“Heater ON” will appear in the LCD display; the heater should be ON now. Turn the thermostat down by tapping on the Down arrow button.

The small 22 gauge wire connection on the back of the thermostat
is for the remote 40°/5°C or 60°/16°C activation. This is a volt-free
set of control wires that can be used with any switch, such as:
window and door contacts, motion sensors, key cards, hotel
panels and evrything that can make or break contact. 40°/5°C or
60°/16°C set back is activated on contact open.
Page 3
SPECIFICATIONS:
Temperature range: 40°F/5°C to 74°F/23°C
Temperature Default: Your set point 60°F/16°C
to 40°F/5°C
Display Format: Liquid Crystal Display (LCD)
Display size: Large Format
Sample Rate: Every 60 seconds
Heat indicator: LCD “heater on”
Window Contacts OPEN. (LCD) OPN
Relay Rating: 16 Amps inductive or resistive
Accuracy: ± 0.9°F/±0.5°C
Maximum Amps: 16 inductive continuos
Maximum Watts: 1875 @ 120V
3328 @ 208V
3840 @ 240V
Total inductive motor load combined can not exceed
16 amps
Minimum Watts:0
Power Supply Rated 208/240 VAC
Operating Range 200 to 250 VAC
40°F/5°C
WINDOW
CONTACTS 60°F/16°C
MOTION
SENSOR
CONTACTS
Optional:
60°F/16°C set back on open
Contact factory.
May need special order.
40°F/5°C set back
on open contacts
BLUE/ WHITE
240V/ 120V
BLUE/ WHITE
240V/ 120V
Produktspecifikationer
Varumärke: | King |
Kategori: | Termostat |
Modell: | WR120-B-KIT |
Behöver du hjälp?
Om du behöver hjälp med King WR120-B-KIT ställ en fråga nedan och andra användare kommer att svara dig
Termostat King Manualer

12 September 2024

12 September 2024

4 September 2024

27 Augusti 2024

22 Augusti 2024

22 Augusti 2024

19 Augusti 2024

17 Augusti 2024

16 Augusti 2024

13 Augusti 2024
Termostat Manualer
- Termostat ATAG
- Termostat Bosch
- Termostat AEG
- Termostat Panasonic
- Termostat Honeywell
- Termostat Junkers
- Termostat Nefit
- Termostat Remeha
- Termostat Siemens
- Termostat Vaillant
- Termostat Ambiano
- Termostat Alecto
- Termostat Airwell
- Termostat Amfra
- Termostat Brennenstuhl
- Termostat Google
- Termostat GE
- Termostat Silvercrest
- Termostat Renkforce
- Termostat Itho
- Termostat De Dietrich
- Termostat TP Link
- Termostat Daikin
- Termostat Elro
- Termostat EMOS
- Termostat Truma
- Termostat Energenie
- Termostat Schneider
- Termostat Hama
- Termostat Fenix
- Termostat Theben
- Termostat AVM
- Termostat Elektrobock
- Termostat Devi
- Termostat Stiebel Eltron
- Termostat Buderus
- Termostat Velleman
- Termostat Dimplex
- Termostat Emerson
- Termostat Vemer
- Termostat Ferroli
- Termostat Magnum
- Termostat Horstmann
- Termostat Salus
- Termostat Perel
- Termostat Tylö
- Termostat Somfy
- Termostat Corberó
- Termostat Oventrop
- Termostat AcuRite
- Termostat Technoline
- Termostat Arnold Rak
- Termostat Cotech
- Termostat Heatmiser
- Termostat Viessmann
- Termostat Carrier
- Termostat Nest
- Termostat Itho-Daalderop
- Termostat Hive
- Termostat Danfoss
- Termostat Saunier Duval
- Termostat Netatmo
- Termostat Seitron
- Termostat Hager
- Termostat Bticino
- Termostat Sygonix
- Termostat TFA
- Termostat Tado
- Termostat Hunter
- Termostat Plieger
- Termostat Aube
- Termostat Tesla
- Termostat Rademacher
- Termostat Busch-Jaeger
- Termostat Zehnder
- Termostat Bulex
- Termostat UPM
- Termostat Optima
- Termostat AWB
- Termostat Finder
- Termostat Xavax
- Termostat Fantini Cosmi
- Termostat Delta Dore
- Termostat Orbis
- Termostat Niko
- Termostat Boneco
- Termostat EBERLE
- Termostat Grasslin
- Termostat Gira
- Termostat Jung
- Termostat Basetech
- Termostat Wolf
- Termostat HQ
- Termostat Eneco
- Termostat Frico
- Termostat Vasco
- Termostat Radson
- Termostat Nobo
- Termostat Baxi
- Termostat Fibaro
- Termostat Nexa
- Termostat EQ3
- Termostat Homematic IP
- Termostat Go Green
- Termostat Landis Gyr
- Termostat Weishaupt
- Termostat REMKO
- Termostat ICY
- Termostat HomeMatic
- Termostat Computherm
- Termostat Avidsen
- Termostat Heimeier
- Termostat SPC
- Termostat Crestron
- Termostat ORNO
- Termostat Drayton
- Termostat Westfalia
- Termostat Cepra
- Termostat Heatit
- Termostat 2Heat
- Termostat Bryant
- Termostat Watts
- Termostat Eqiva
- Termostat Etherma
- Termostat Veria
- Termostat Emmeti
- Termostat Thermy
- Termostat Ferguson
- Termostat Eurotronic
- Termostat Oregon Scientific
- Termostat POER
- Termostat Muller
- Termostat Worcester-Bosch
- Termostat Econo-Heat
- Termostat VDH
- Termostat Vimar
- Termostat PECO
- Termostat IR-V
- Termostat H-Tronic
- Termostat EasyTemp
- Termostat Elgato
- Termostat Intertechno
- Termostat Schwaiger
- Termostat Helios (Amfra)
- Termostat EQ-3
- Termostat Tru Components
- Termostat Emko
- Termostat Easy Timer
- Termostat Z-Wave
- Termostat Hugo Muller
- Termostat IMIT
- Termostat Innogy
- Termostat Wallair
- Termostat Maico
- Termostat Levica
- Termostat HomePilot
- Termostat Ouellet
- Termostat Techno Line
- Termostat THERMAFLEX
- Termostat Wachendorff
- Termostat Yokis
- Termostat ChiliTec
- Termostat Eliwell
- Termostat Plugwise
- Termostat Johnson Control
- Termostat Webasto
- Termostat Drayton Erie
- Termostat OJ ELECTRONICS
- Termostat Tellur
- Termostat RWE
- Termostat ATTACK
- Termostat Lowes
- Termostat Jumo
- Termostat Warmup
- Termostat Qubino
- Termostat STI
- Termostat ELKO
- Termostat TrickleStar
- Termostat Gewiss
- Termostat Sinustec
- Termostat Rose LM
- Termostat Otio
- Termostat MundoControl
- Termostat Enda
- Termostat Bearware
- Termostat GENERAL Life
- Termostat Oreg
- Termostat Braeburn
- Termostat Konyks
- Termostat Feller
- Termostat Sorel
- Termostat Wodtke
Nyaste Termostat Manualer

22 Mars 2025

21 Mars 2025

27 Februari 2025

27 Februari 2025

21 Februari 2025

2 Februari 2025

29 Januari 2025

16 Januari 2025

16 Januari 2025

16 Januari 2025