How to use:
Measuring human body temperature in the ear canal
1. Press the on/recall button to turn on
the thermometer, a beep sound is
heard and the LCD displays as Fig A in
one second. When the LCD displays as
Fig B, now it’s ready to measure.
2. Straighten the ear canal by pulling the
outer ear up and back to give a clear
view of the eardrum.
For children under 1 year, pull the ear
straight back.
For children ages 1 year to adult, pull
the ear up and back.
Fig A
Newborn –
1year
1 year – adult
Fig B
(Caution: Many pediatricians suggest use of ear thermometers for children
older than 6 months).
3. While pulling the outer ear, insert the probe snugly into the ear canal
(best to insert deep), press the “scan” button. Release it, when you hear
a beep sound. A beep indicates measurement is complete. Remove the
thermometer from the ear. The display shows the measure temperature.
4. Measuring again: If measuring again, please unclinch the “scan” button and
wait for the “ ” symbol to display, then press “scan” button to measure
again.
Note: The time between each reading should be not less than 1 min.
5. Memory search: Press the “on/recall”
button, the last ten memories
(No.9–No. 0) will take turns to display
on the LCD as Fig C and Fig D.
6. The LCD will display “ER 1” as Fig E and
cannot display temperature when the
ambient temperature is of the range
of 10 °C to 35 °C.
Note: Before measuring, the
thermometer shall be stabilized at
the operating ambient condition for a
minimum of 30 min.
Fig C Fig D
Fig E
7. Shut o: The thermometer shall automatically shut o without
3
ENGLISH
manipulating in one minute.
Note:
In order to avoid spreading germs,
please use a new disposable probe
cover for each measurement.
Check to ensure probe cover is tted
on rmly before use (please see the
diagrams right). If the probe cover is
broken or discarded, apply a new one
immediately.
Incorrect Correct
Cleaning and storage:
1. Store thermometer and the disposable probe cover in a dry location free
from dust and contamination and away from direct sunlight. The ambient
temperature at the storage location should remain fairly constant and
within the range of -10 °C to 55 °C.
2. Use an alcohol swab or cotton swab moistened with alcohol (70%) to clean
the thermometer casing and the measuring probe. Ensure that no liquid
enters the interior of the thermometer.
3. Never use abrasive cleaning agents, thinners
or gasoline for cleaning and never immerse the
instrument in water or other cleaning liquids. Take
care not to scratch the surface of the probe membrane
or display.
Replacing the batteries:
1. When voltage of the batteries are low, the LCD will display “ ” symbol,
please replace two new batteries in the unit. The thermometer cannot work
accurately under the condition of low voltage.
2. The thermometer is supplied with two 1.5 V AAA alkalescency batteries.
Insert new batteries when the low voltage symbol appears on the LCD.
3. Place two new batteries according to the + and –.
4. Please take out the batteries to avoid battery leaking if unit not used for
over six months.