Test Report: GC220A12
220W Single Output Switching Power Supply
DESIGN VERIFY TEST
Output Function Test
Input Function Test
Protection Function Test
Component Stress Test
SAFETY & E.M.C. TEST
Safety Test
E.M.C. Test
RELIABILITY TEST
ENVIRONMENT TEST
GC220A
series
Model: GC220A12 Test Report 2 / 7
DESIGN VERIFY TEST
OUTPUT FUNCTION TEST
NO TEST ITEM SPECIFICATION TEST CONDITION RESULT VERDICT
1 DC VOLTAGE (Typ.) 13.6V I/P 230 VAC
I/P 115 VAC
O/PFULL LOAD
Ta25
13.149 V /230V
13.147 V /115V P
2 CONTINUOS OUTPUT
CURRENT (Typ.)
13.5A I/P 230 VAC
I/P 115 VAC
O/PFULL LOAD
Ta25
13.220 A /230V
13.231A /115V P
3 LED INDICATOR Charging(CC) : RED
Floating charging(CV) : GREEN
I/P 230 VAC
O/Psetting
Ta25
< 1.392A,LED :RED
1.346A,LED :GREEN P
INPUT FUNCTION TEST
NO TEST ITEM SPECIFICATION TEST CONDITION RESULT VERDICT
1 INPUT VOLTAGE RANGE 90VAC~264 VAC I/PTESTING
O/PFULL LOAD
Ta25
69-45V~264V
P
I/P
LOW-LINE-3V= 87 V
HIGH-LINE+15%=300 V
O/PFULL/MIN LOAD
ON 30 Sec . OFF 30 Sec 10MIN
( AC POWER ON/OFF NO DAMAGE )
TEST OK
2 INPUT FREQUENCY
RANGE
47HZ ~63 HZ
NO DAMAGE OSC
I/P90 VAC ~ 264 VAC
O/PFULL~MIN LOAD
Ta25
TEST OK
P
3 POWER FACTOR 0.90 / 230 VAC(TYP) I/P 230 VAC
I/P 115 VAC
O/PFULL LOAD
Ta25
PF= 0.9246 / 230 VAC
P
0.98 / 115 VAC(TYP) PF= 0.9917 / 115 VAC
4 EFFICIENCY 89 % (TYP) I/P 230 VAC
O/PFULL LOAD
Ta25
90.654 %
P
5 INPUT CURRENT 230V/ 2 A (TYP) I/P 230 VAC
I/P 115 VAC
O/PFULL LOAD
Ta25
I =
0.8842 A/ 230 VAC
P
115V/ 4 A (TYP) I =
1.6866 A/ 115 VAC
6 INRUSH CURRENT 230V/ 120 A (TYP) I/P 230 VAC
O/PFULL LOAD
Ta25
I =
109 A/ 230 VAC
P
COLD START
7 LEAKAGE CURRENT < 1.5 mA / 240 VAC I/P 264 VAC
O/PMin LOAD
Ta25
L-FG 0.005 mA
P
N-FG
0.005 mA
GC220A
series
Model: GC220A12 Test Report 3 / 7
PROTECTION FUNCTION TEST
NO TEST ITEM SPECIFICATION TEST CONDITION RESULT VERDICT
1 OVER LOAD PROTECTION 90 %~ 110 % I/P 230 VAC
I/P 115 VAC
O/PTESTING
Ta25
98.31%/ 230 VAC
98.05%/ 115 VAC
Constant Current Limiting
P
2 OVER VOLTAGE PROTECTION CH1 14.28 V~ 18.36 V I/P 230 VAC
I/P 115 VAC
O/PMIN LOAD
Ta25
17.1 V/ 230 VAC
17.4 V/ 115 VAC
Shut down Re- power ON
P
3 OVER TEMPERATURE PROTECTION SPEC
TSW1 95 + 10 O.T.P.
NO DAMAGE
I/P 230 VAC
O/PFULL LOAD
O.T.P. Active
Shut down o/p voltagerecovers
automatically after temperature
goes down P
4 SHORT PROTECTION SHORT EVERY OUTPUT
1 HOUR NO DAMAGE
I/P 264 VAC
O/PFULL LOAD
Ta25
NO DAMAGE
Hiccup mode
P
5 NO LOAD POWER CONSUMPTION < :1W I/P 230 VAC
I/P 115 VAC
O/PMIN LOAD
Ta25
0.67 W/ 230 VAC
0.73 W/ 115 VAC
P