Milwaukee 2237-20 Bruksanvisning

Läs nedan 📖 manual på svenska för Milwaukee 2237-20 (20 sidor) i kategorin Multimeter. Denna guide var användbar för 5 personer och betygsatt med 4.5 stjärnor i genomsnitt av 2 användare

Sida 1/20
Cat. No. / No de cat.
2236-20, 2237-20
OPERATOR'S MANUAL
MANUEL de L'UTILISATEUR
MANUAL del OPERADOR
WARNING To reduce the risk of injury, user must read and understand operator's manual.
AVERTISSEMENT An de réduire le risque de blessures, l'utilisateur doit lire et bien
comprendre le manuel.
ADVERTENCIA Para reducir el riesgo de lesiones, el usuario debe leer y entender el manual.
CLAMP METERS
PINCE AFFICHEUR DE COURANT
MEDIDORES DE PINZA
2
WARNING
READ ALL SAFETY WARNINGS AND IN-
STRUCTIONS.
Failure to follow the warnings and instructions
may result in electric shock, re and/or serious
injury, as well as instrument damage and/or dam-
age to the equipment being tested.
Save these instructions - This operators manual
contains important safety and operating instruc-
tions for the MILWAUKEE Clamp Meters. Before
using, read this operators manual and all labels
on the Clamp Meters.
DANGER
Never make measurement on a circuit in which
voltage over AC600V exists. Use only leads rated
600V or better.
Do not attempt to make measurement in the pres-
ence of ammable gasses. Otherwise, the use of
the instrument may cause sparking, which can
lead to an explosion.
Transformer jaw tips are designed not to short the cir-
cuit under test. If equipment under test has exposed
conductive parts, however, extra precaution should
be taken to minimize the possibility of shorting.
Never attempt to use the instrument if its surface
or your hand is wet.
Do not exceed the maximum allowable input of
any measuring range.
Only test on unenergized circuits unless abso-
lutely necessary.
Check tool functionality on a known circuit rst.
Never assume tool is working. Assume circuits are
live until they can be proven de-energized.
Do not ground yourself while measuring. Avoid
body contact with earthed or grounded surfaces
such as pipes, radiators, ranges and refrigerators.
Never open the Battery cover during a measurement.
The instrument is to be used only in its intended
applications or conditions. Otherwise, safety func-
tions equipped with the instrument doesn’t work,
and instrument damage or serious personal injury
may be caused.
To reduce the risk of injury from shock and arc
blasts, always wear personal protective equipment
where live conductors are exposed.
WARNING
Never attempt to make measurement if any abnor-
mal conditions, such as broken case and exposed
metal parts are found on the instrument.
Do not rotate the Rotary Dial while the test leads
are being connected.
Verify proper operation on a known source before
use or taking action as a result of the indication
of the instrument.
Do not install substitute parts or make any modi-
cation to the instrument. For repair or re-cali-
bration, return the tool to a factory Service/Sales
Support Branch or authorized service station.
Do not try to replace the batteries if the surface of
the instrument is wet.
Disconnect all the cords and cables from the object
under test and power off the instrument before
opening the Battery Cover for Battery replacement.
This tool is designed to be powered by 2-AA batter-
ies properly inserted into the MILWAUKEE Clamp
Meters. Do not attempt to use with any other volt-
age or power supply.
Install battery according to polarity (+ and –) diagrams.
Do not leave batteries within the reach of children.
Do not mix new and used batteries. Do not mix
brands (or types within brands) of batteries.
Properly dispose of used batteries.
Do not incinerate or dismantle batteries.
Under abusive conditions, liquid may be ejected
from the battery, avoid contact. If contact acciden-
tally occurs, ush with water. If liquid contacts
eyes, additionally seek medical help. Liquid eject-
ed from the battery may cause irritation or burns.
CAUTION
Set the Rotary Dial to an appropriate position
before starting measurement.
Firmly insert the test leads.
Disconnect the test leads from the instrument for
current measurement.
Do not expose the instrument to the direct sun,
high temperature and humidity or dew fall.
Altitude 2000m or less. Appropriate operating
temperature is within -10ºC and 50ºC.
This instrument isn’t dust & water proofed. Keep
away from dust and water.
Be sure to power off the instrument after use. When
the instrument will not be in use for a long period,
place it in storage after removing the batteries.
Use a cloth dipped in water or neutral detergent
for cleaning the instrument. Do not use abrasives
or solvents.
GENERAL SPECIFICATIONS
Cat. No. 2236-20, 2237-20 ......................................
Accuracy is specied for 1 year after calibration, at
operating temperatures of 6F to 8F (1C to
28°C), with relative humidity at 0 % to 85 %.
Maximum voltage between any
terminal and earth ground ...................... 600 V
Jaw Opening .......................approx. 1.3" (33 mm)
(maximum conductor size)
Temperature
Operating .............14°F to 122°F (-10°C to 50°C)
Storage .............. -40°F to 140°F (-40°C to 60°C)
Temperature Coefcient ...............................0.1 x
(specied accuracy)/°C (<18°C or >28°C)
Operating Altitude ............................2,000 meters
Drop Test ................................................... 1 Meter
Battery ........................ 2 AA, NEDA 15 A,IEC LR6
Battery Life ..............Approx. 30 Hours all lights on
Safety Compliances ....... UL/CSA 61010-1 3rd Ed
UL/CSA 61010-2-033 1st Ed (Meters)
UL/CSA/IEC/EN 61010-031 1st Ed + A1 (Probes)
UL/CSA 61010-2-032 1st Edition (Clamp Assemblies)
Measurement Category III, 600V
Pollution Degree 2, EMC EN61326-1
Certications............................................... cULus
IMPORTANT
SAFETY
INSTRUCTIONS
3
SYMBOLOGY
Read Operator's Manual
Double insulation
Risk of electric shock
Indicates that this instrument can clamp
on bare conductors when measuring a
voltage corresponding to the applicable
measurement category, which is
marked next to this symbol.
Earth (Ground)
Danger, Warning, or Caution-
Consult the operator's manual for
additional safety information.
Battery compartment
CUS
UL Listing for Canada and U.S
Cat III Classication of transient overvoltages,
based on nominal line voltage to earth.
Do not dispose of this product as
unsorted municipal waste.
FUNCTIONAL DESCRIPTION
1. Current sensing jaws
2. NCVD indicator
3. Jaw opening trigger
4. Rotary Dial
5. Display
6. Zero button
1
3
10
11
5
9
7
6
4
4
2
Cat. No.
2237-20
Cat. No.
2236-20
7. °F/°C button (2236-20)
Hz button (2237-20)
8. Terminal inputs
9. Min/Max button
10. Worklight LED
11. Hold button
8
FUNCTIONS
Dial Position Range Resolution Accuracy
Voltage DC 60/600V 0.01V/0.1V ±1.0%rdg±3dgt
Voltage AC 0.0 to 600.0V 0.1V ±1.5%rdg±4dgt (50/60Hz)
±3.5%rdg±5dgt (40~400Hz)
Current AC
0 to 600.0A
Peak 1500A
CF=2.5@600A
CF=3.0@500A
0.1A
±2.0%rdg±5dgt(50/60Hz)
±3.5%rdg±5dgt(40 ~ 400Hz)
* Add 2% at CF>2
* < 5A, add 3dgt
Current DC
(2237-20) 0-600.0A 0.1A ±1.5%rdg±5dgt
Resistance 600Ω/6kΩ 0.1Ω/0.001kΩ ±1.0%rdg±5dgt
Capacitance 0.01nF - 4000μF
Auto-ranging
0.01nF/0.1nF/
0.001μF/0.01μF/
0.1μF/1μF
0.01nF-39.99nF 2.5% 2nF± ±
40.00nF-1000uF 2.5% 20dgt± ±
1000uF> 5% 20dgt± ±
Continuity Cont Buzzer
0-600.0Ω
Buzzer sounds at 35Ω ±10Ω or 25Ω or
less
uA Current
DC uA (2236-20) 0-600.0uA 0.1 ±1.5%rdg±5dgtuA
Temperature
(2236-20)
-40C - 400C
-40F - 32.0F
32.1F - 752F
0.1C
0.1F
±1.0%C ±2.0C
-40.0F to 20.0F; 1.5%F 4F± ±
20.1F to 752F; 1.5%F 2F± ±
Hz Hertz (2237-20) ACA: 40-400Hz,
ACV: 1Hz-10kHz
0.001/0.01/0.1Hz
0.001/0.01kHz
ACA: 40-400Hz 0.5%rdg 5dgt± ±
ACV:1Hz-10kHz ±0.5%rdg±5dgt
* Minimum Measurable inputs are: 70
Vrms for VAC or 50 Arms for ACA
* These instruments are True-RMS sensing. All voltage and current readings are True-RMS values.

Produktspecifikationer

Varumärke: Milwaukee
Kategori: Multimeter
Modell: 2237-20

Behöver du hjälp?

Om du behöver hjälp med Milwaukee 2237-20 ställ en fråga nedan och andra användare kommer att svara dig




Multimeter Milwaukee Manualer

Multimeter Manualer

Nyaste Multimeter Manualer