OPERATOR'S MANUAL
MANUEL de L'UTILISATEUR
MANUAL del OPERADOR
TO REDUCE THE RISK OF INJURY, USER MUST READ AND UNDERSTAND OPERATOR'S
MANUAL.
AFIN DE RÉDUIRE LE RISQUE DE BLESSURES, L'UTILISATEUR DOIT LIRE ET BIEN
COMPRENDRE LE MANUEL DE L'UTILISATEUR.
PARA REDUCIR EL RIESGO DE LESIONES, EL USUARIO DEBE LEER Y ENTENDER EL
MANUAL DEL OPERADOR.
TRUE RMS MULTIMETER (DMM)
MULTIMÈTRE D'EFFICACITÉ VÉRITABLE (DMM)
MULTÍMETRO CON RMS VERDADERO (DMM)
Cat. No.
No de cat.
2217-20

23
IMPORTANT SAFETY INSTRUCTIONS
WARNING READ ALL SAFETY WARNINGS AND INSTRUCTIONS. Failure to
follow the warnings and instructions may result in electric shock, fi re and/or serious
injury, as well as instrument damage and/or damage to the equipment being tested. Save these
instructions - This operator’s manual contains important safety and operating instructions
for the MILWAUKEE True RMS Multimeters (DMM). Before using, read this operator’s manual
and all labels on the True RMS Multimeters.
DANGER
Never make measurement on a circuit in which voltage over 600V rms exists. Use only leads
rated 600V CATIII or better.
Do not apply more than the rated voltage, as marked on the DMM, between terminals or be-
tween any terminal and earth ground.
Do not attempt a current measurement when the open voltage is above the fuse protection
rating. Suspected open circuit voltage can be checked with voltage function.
Do not use the DMM to measure voltages in circuits that could be damaged by the DMM’s low
input impedance in Lo-Z Function. Impedance is approximately 4K .Ω
Do not attempt to make measurement in the presence of fl ammable gases. Otherwise, the use
of the instrument may cause sparking, which can lead to an explosion.
Never attempt to use the instrument if its surface or your hand is wet.
Do not exceed the maximum allowable input of any measuring range.
Only test on unenergized circuits unless absolutely necessary.
Check tool functionality on a known circuit fi rst. Never assume tool is working. Assume circuits
are live until they can be proven de-energized.
Never open the Battery cover during a measurement.
Do not ground yourself while measuring. Avoid body contact with earthed or grounded sur-
faces such as pipes, radiators, ranges and refrigerators.
This instrument is to be used only in its intended applications or conditions. Otherwise, the instru-
ment's safety functions may not work, resulting in serious personal injury and instrument damage.
To reduce the risk of injury from shock and arc blasts, always wear personal protective
equipment where live conductors are exposed.
WARNING
Never attempt to make measurement if any abnormal conditions, such as broken case and
exposed metal parts are found on the instrument.
Comply with local and national safety requirements when working in hazardous locations.
Keep fi ngers behind the guards and away from test lead tips during measurements.
Do not rotate the Rotary Dial while the test leads are being connected.
Never attempt a voltage measurement with the test lead inserted into the A input terminal.
Verify proper operation on a known source before use or taking action as a result of the in-
dication of the instrument.
Do not install substitute parts, replace fuse or make any modifi cation to the instrument. For
repair or re-calibration, return the tool to a factory Service/Sales Support Branch or authorized
service station.
Do not try to replace the batteries if the surface of the instrument is wet.
Disconnect all the cords and cables from the object under test and power off the instrument
before opening the Battery Cover for Battery replacement.
This tool is designed to be powered by 2-AA batteries properly inserted into the MILWAUKEE
True RMS Multimeters. Do not attempt to use with any other voltage or power supply.
Install battery according to polarity (+ and –) diagrams.
Do not leave batteries within the reach of children.
Do not mix new and used batteries. Do not mix brands (or types within brands) of batteries.
Properly dispose of used batteries.
Do not incinerate or dismantle batteries.
Under abusive conditions, liquid may be ejected from the battery, avoid contact. If contact
accidentally occurs, fl ush with water. If liquid contacts eyes, additionally seek medical help.
Liquid ejected from the battery may cause irritation or burns.

45
CAUTION
Set the Rotary Dial to an appropriate position before starting measurement.
Disconnect test leads from test points before changing Rotary Dial functions.
Never connect to a source of voltage with the Dial function in OFF/ / / / / / .Ω
Firmly insert the test leads.
Do not expose the instrument to the direct sun, high temperature and humidity or dew fall.
Altitude 2000m or less. Appropriate operating temperature is within -10ºC and 50ºC.
Keep away from excess dust and water.
Be sure to power off the instrument after use. When the instrument will not be in use for a long
period, place it in storage after removing the batteries.
Use a damp cloth or neutral detergent for cleaning the instrument. Do not use abrasives or
solvents.
Accuracy is specifi ed for 1 year after calibration, at operating temperatures of 18°C to 28°C (64°F to
82°F), with relative humidity at 45 % to 85 %.
General Specifi cations
FUNCTIONAL DESCRIPTION
1. Display
2. Range button
3. °F/°C button
4. Backlight button
5. VΩ Terminal input
6. COM Terminal input
7. A mA Terminal input
8. Rotary Dial
9. Min/Max button
10. Hold button
11. Accessory bay (on back, not shown)
4
2
1
3
5
6
7
8
9
10
Maximum voltage between
any terminal and earth ground
600 V Cat III Rated
Temperature Operating: -10°C to 50°C (14°F to 122°F)
Current measurements: -10°C to 40°C (14°F to 104°F)
Storage: -40°C to 60 °C (-40°F to 140°F)
Temperature Coeffi cient 0.1 x (specifi ed accuracy)/°C (<18°C or >28°C)
Operating Altitude 2,000 meters
IP Rating (International Dust
& Water Protection)
IP54
Drop Test 1 Meter
Battery 2 AA, NEDA 15 A,IEC LR6
Battery Life Approx. 26 Hours all lights on
Fuse 600V AC/DC, 10A Fast-acting (Milwaukee p/n 22-89-0305)
Safety Compliances EN61010-1, UL 61010-1, UL 61010-031 (Probes), EN61010-031
(Probes), IEC/EN 61010-1 2nd Edition for measurement
Category III, 600 V, Pollution Degree 2, EMC EN61326-1
Certifi cations cULus, CE
Symbology
Read Operator’s Manual
Double insulation
Risk of electric shock
Earth
Danger, Warning, or Caution - Consult the operators manual for additional safety
information.
Battery compartment
European Conformity Mark
Underwriters Laboratories, Inc.,
United States and Canada
Cat III Classifi cation of transient overvoltages, based on nominal
line voltage to earth.
Fuse
Do not dispose of this product as unsorted municipal waste.
Produktspecifikationer
Varumärke: | Milwaukee |
Kategori: | Multimeter |
Modell: | RMS 2217-20NST |
Behöver du hjälp?
Om du behöver hjälp med Milwaukee RMS 2217-20NST ställ en fråga nedan och andra användare kommer att svara dig
Multimeter Milwaukee Manualer

15 September 2024

4 September 2024

23 Augusti 2024

9 Augusti 2024

6 Augusti 2024

31 Juli 2024
Multimeter Manualer
- Multimeter Abus
- Multimeter Alecto
- Multimeter Appa
- Multimeter Amprobe
- Multimeter Amiko
- Multimeter Silverline
- Multimeter Brennenstuhl
- Multimeter Ferm
- Multimeter Workzone
- Multimeter Yato
- Multimeter Elro
- Multimeter EMOS
- Multimeter Extech
- Multimeter Tacklife
- Multimeter Schneider
- Multimeter Metrix
- Multimeter Benning
- Multimeter Voltcraft
- Multimeter Somogyi
- Multimeter Velleman
- Multimeter Profile
- Multimeter Steren
- Multimeter Kyoritsu
- Multimeter Ideal
- Multimeter Flir
- Multimeter Maxwell
- Multimeter Digitus
- Multimeter Testboy
- Multimeter Hager
- Multimeter TFA
- Multimeter Clas Ohlson
- Multimeter Powerfix
- Multimeter Owon
- Multimeter Fluke
- Multimeter Basetech
- Multimeter Projecta
- Multimeter Etekcity
- Multimeter Greenlee
- Multimeter Högert
- Multimeter Laserliner
- Multimeter REV
- Multimeter Testo
- Multimeter Keithley
- Multimeter Monacor
- Multimeter Metrel
- Multimeter Multimetrix
- Multimeter Digi-tool
- Multimeter Brandson
- Multimeter GW Instek
- Multimeter Skandia
- Multimeter Elma
- Multimeter Testec
- Multimeter Beha-Amprobe
- Multimeter Hubinont
- Multimeter Vimar
- Multimeter Uni-T
- Multimeter Kewtech
- Multimeter Strex
- Multimeter Mastech
- Multimeter PeakTech
- Multimeter Sonel
- Multimeter MBS
- Multimeter MGL Avionics
- Multimeter Chauvin Arnoux
- Multimeter Megger
- Multimeter Gossen Metrawatt
- Multimeter Rigol
- Multimeter PCE Instruments
- Multimeter Micronta
- Multimeter CEM
- Multimeter Horex
- Multimeter Cosinus
- Multimeter Joy-it
- Multimeter Klein Tools
- Multimeter Aim TTi
- Multimeter Kurth Electronic
- Multimeter Wiha
- Multimeter IWH
- Multimeter Weltron
- Multimeter Sanwa
- Multimeter Rohde & Schwarz
- Multimeter EEVBlog
- Multimeter Kingcraft
- Multimeter Weidmüller
- Multimeter HT Instruments
- Multimeter Caltek
- Multimeter Elworks
- Multimeter Qian
- Multimeter Bearware
- Multimeter Noyafa
Nyaste Multimeter Manualer

14 Mars 2025

14 Mars 2025

8 Januari 2025

3 Januari 2025

1 Januari 2025

29 December 2024

29 December 2024

29 December 2024

29 December 2024

28 December 2024