EN-1
2.3-4.0 m
(7.6-13 ft.)
INSTALLATION AND MAINTENANCE NOTES
Warning Caution
Never repair or
modify product
Hold the main unit
securely when you
install or service it.
If you remove your
hands from the main
unit when cables are
connected to it, the
main unit may fall
and the connector
cables may break
or the circuit board
may be damaged.
Caution
Verify that the
power is off before
connecting the
wiring.
2
PARTS IDENTIFICATION
1
59-3462-0 2310-11
INSTALLATION INSTRUCTIONS
Synthesized Intelligent PIR
REDWALL-V series
Synthesized Intelligent PIR
REDWALL-V series
FEATURES
,CDV9-3( noitpmusnoc rewop woL * 40μA (standby) 5mA max.)
* Low battery signal
* Intelligent PIR Detection System
- Three dual pyro-elements with patented Double Conductive
Shielding
- Detection of ambient temperature and illuminance for
automatic sensitivity management
- Advanced detection algorithm
* Anti-vandalism functions
- Max.4 m (13 ft.) installation height
- Anti-rotation function with accelerometer
- Anti-masking function with photo-beam
* Independent sensitivity selector for near/far areas
* Detection logic selector
* Detection range selector
* Independent N.C. and N.O. ALARM output
* Adjustable alarm interval time
* Reinforced polycarbonate housing
REDWALL-V
: Low current Synthesized Intelligent PIR
SIP-3020WF
SIP-4010WF
SIP-404WF
•
•
•
Mount the detector so that the majority of is across the detection pattern.traffic flow
dna FW0104-PIS eht rof desu toN :1*
SIP-404WF.
2-1
INSTALLATION HINTS
Base
Fixing screw
for the base
Main unit
Masking plate for near
area (*1)
Fixing rubber
form (*1)
Window
Fixing screw
for the cover
Cover
Far area mirror
Masking plate for far area
Fixing rubber form
Adjustment screws
(two facing each other)
Angle adjustment guide
Near area mirror
Arrow marking
Fixing screw
Nylon wire
loop
When servicing, the sensor
can be hooked onto the
base using the nylon wire
loop.
*UL-1: When assessing the installation and application, alarms triggered
by conditions such as weather, blowing leaves and bush, or related
environmental conditions, etc., need to be considered.
It is recommended that the intrusion detection unit is not to be
connected to an alarm initiating circuit but may be connected to
a trouble alarm circuit if nuisance trips are not tolerable.
EN-2
3-1
Wall Mounting
Attach the paper template (an accessory) onto the wall,
and drill a 6-mm dia. mounting hole and a cabling hole.
Insert the anchor bolt (an accessory) into the board mount
hole.
Using an allen key, remove the main unit from the base.
Drill through the bushing of the wiring hole, pass the cable
through the hole, and secure the base to the wall.
Connect the cable to the terminal block (see Step 3-3).
Mount the main unit onto the base.
Cautions>>
When mounting the main unit, take care not to trap the
nylon wire loop. Also, take care not to get your fingers
caught.
Check to see that the various settings and operations are
correct.
Caution>>
When the red LED flashes after the power turns on,
this signifies that the system is warming up. Wait for
approximately 120 seconds.
INSTALLATION AND ANGLE ADJUSTMENT
3
(1)
(2)
(3)
(4)
(5)
(6)
3-2
Inside View of the Base
3-3
WIRING
Cautions>>
Maximum wiring length is 3 m.
Name Function
TROUBLE
OUTPUT
Trouble out is used for anti-masking signal and
low battery signal. When an object is placed close
to the lens surface, for a period of more than
120 seconds (approx.), the IR anti-masking circuit
will activate and generate a trouble signal.
When the battery power is less than 2.3V DC, and
this condition continues more than 2.5 hours, the
signal will be generated.
TAMPER
OUTPUT
It is detected when the cover is opened.
It is detected when the main unit is removed from
its base.
Anti-Rotation:
Damage sustained by the main unit is detected.
If the main unit is impacted in a horizontal or
vertical direction and if the position of the main
unit has changed, damage sustained by the main
unit will be detected.
Waterproof seal
(Do not remove
this seal.)
Base
Bushing of wiring
hole
Open wiring cap
Main unit connector
Wall mounting hole
Wall mounting hole
Bushing of wiring
hole
Wiring terminals
① Loosen the
fixing screw
for the
base.
② Open.
③ Unplug
the cable
connector.
④ Pull out.
POWER INPUT
TAMPER OUTPUT *1
ALARM OUTPUT (N.C.)
ALARM OUTPUT (N.O.)
TROUBLE
OUTPUT
SPARE
④ Tighten and
secure the
fixing screw
for the base.
② Connect the
connector.
③ Close.
① Insert and
secure here.
Nylon
wire
loop
Distance from the ground to
the bottom of the template
must be between 2.3 m (7.6 ft.)
and 4 m (13 ft.).
* The Cable Gland (accessory )
enables wiring.
*1: TAMPER terminals to be connected to a 24 hour supervisory loop.
(*UL-3)
*UL-3: UL/ULC required the unit to be connected to a UL/ULC Listed
control panel or a power limited Listed Burglar alarm power supply
capable of providing a minimum of 4 hours of battery standby power
for UL/ULC Listed application.
*UL-2: Minimum wire gauge is 22 AWG.
Wiring methods shall be accordance with the National Electrical Code
NFPA 70 or CSA 22.2, Part 1 of the Electrical code for Canada.
EN-3
DETECTION AREA SETTING
You can adjust the detection area by 90 degrees in a horizontal
direction and by 10 degrees in a vertical direction.
Correct the vertical detection angle according to the mounting
height of the sensor unit.
10°
10°
90° 90°
SIP-3020CAM D
Cautions>>
To rotate the main unit counterclockwise, loosen the
RHside adjustment screw. To rotate the main unit
clockwise, loosen the LH-side adjustment screw.
Otherwise, you may find it difficult to tighten or you may
find that you cannot tighten the adjustment screw when
you are securing the main unit.
To rotate the unit counterclockwise
To rotate the unit clockwise
4Adjust the angle of the main unit in a horizontal direction so
that you can cover the desired detection area.
Adjust the angle of the main unit in a vertical direction so
that you can cover the desired detection area.
θ
Cautions>>
If the mounting wall is at an angle, the arrow of the
main unit may exceed the top or bottom limit of “Angle
adjustment guide”. Always check this using the area
viewfinder or the walk tester. If the detection area is
too high or too low, an object outside the detection
area may be detected or incorrect object detection may
occur.
Remove the cover.
Cautions>>
The cover is linked to the main unit by nylon wire loop so
that the cover does not fall. Do not pull the cover using
excessive force.
(1)
(2)
(3)
When mounted at a
height of 4.0 meters (13ft.)
③ Rotate the main unit.
② Loosen the adjustment screw.
④ Tighten the adjustment screw slightly.
Hooks
③ Slide the cover downward
and release the hooks.
① Loosen two screws for fixing
the cover and pull out the
cover until it stops.
Cover
② Hold the heads of both cover screws with your fixing
hands, and pull down and remove the bottom section
of the cover from the main unit.
Adjustment
screw
① Loosen the screw for fixing
the base.
When mounted
at a height of
2.3 meters
(7.6ft.)
Align the arrow of the main
unit with the “Angle adjustment
guide” of the adjustment
screw. The main unit is usually
adjusted within the width of this
guide.
Angle of top surface
Installation
height
Angle of
top surface(θ)
2.3 m (7.6 ft.) 11.2°
4.0m (13 ft.) 14.4°
Produktspecifikationer
Varumärke: | Optex |
Kategori: | Rörelsedetektor |
Modell: | SIP-3020WF |
Behöver du hjälp?
Om du behöver hjälp med Optex SIP-3020WF ställ en fråga nedan och andra användare kommer att svara dig
Rörelsedetektor Optex Manualer
17 December 2024
17 December 2024
17 December 2024
17 December 2024
17 December 2024
17 December 2024
6 December 2024
6 December 2024
6 December 2024
19 Augusti 2024
Rörelsedetektor Manualer
- Rörelsedetektor Honeywell
- Rörelsedetektor Abus
- Rörelsedetektor Alecto
- Rörelsedetektor Hikvision
- Rörelsedetektor Nedis
- Rörelsedetektor Yale
- Rörelsedetektor Eminent
- Rörelsedetektor Schneider
- Rörelsedetektor Axis
- Rörelsedetektor Theben
- Rörelsedetektor Velleman
- Rörelsedetektor Techly
- Rörelsedetektor Vemer
- Rörelsedetektor Smartwares
- Rörelsedetektor Steren
- Rörelsedetektor Perel
- Rörelsedetektor Steinel
- Rörelsedetektor IFM
- Rörelsedetektor ESYLUX
- Rörelsedetektor Devolo
- Rörelsedetektor Dahua Technology
- Rörelsedetektor Cotech
- Rörelsedetektor Grothe
- Rörelsedetektor Merten
- Rörelsedetektor Goobay
- Rörelsedetektor Hager
- Rörelsedetektor Massive
- Rörelsedetektor Konig
- Rörelsedetektor Busch-Jaeger
- Rörelsedetektor Swann
- Rörelsedetektor DESQ
- Rörelsedetektor Xavax
- Rörelsedetektor Marmitek
- Rörelsedetektor Orbis
- Rörelsedetektor Jung
- Rörelsedetektor DSC
- Rörelsedetektor HQ
- Rörelsedetektor Iget
- Rörelsedetektor Nexa
- Rörelsedetektor Satel
- Rörelsedetektor Wentronic
- Rörelsedetektor Homematic IP
- Rörelsedetektor Vernier
- Rörelsedetektor Crestron
- Rörelsedetektor Chuango
- Rörelsedetektor ORNO
- Rörelsedetektor Berker
- Rörelsedetektor Extron
- Rörelsedetektor Maxsa
- Rörelsedetektor Kopp
- Rörelsedetektor Vimar
- Rörelsedetektor Kogan
- Rörelsedetektor XQ-Lite
- Rörelsedetektor Brinno
- Rörelsedetektor Legrand
- Rörelsedetektor Elgato
- Rörelsedetektor Intertechno
- Rörelsedetektor Schwaiger
- Rörelsedetektor Inovonics
- Rörelsedetektor V-Tac
- Rörelsedetektor Bitron
- Rörelsedetektor EQ-3
- Rörelsedetektor Suevia
- Rörelsedetektor Pentatech
- Rörelsedetektor Joy-it
- Rörelsedetektor RAB
- Rörelsedetektor BEA
- Rörelsedetektor Tellur
- Rörelsedetektor Megatron
- Rörelsedetektor Ledvance
- Rörelsedetektor Gewiss
- Rörelsedetektor ALC
- Rörelsedetektor Avigilon
- Rörelsedetektor GEV
- Rörelsedetektor Pepperl+Fuchs
Nyaste Rörelsedetektor Manualer
17 December 2024
17 December 2024
16 December 2024
16 December 2024
16 December 2024
16 December 2024
16 December 2024
16 December 2024
16 December 2024
16 December 2024