INSTALLATION INSTRUCTIONS
READ AND SAVE THESE INSTRUCTIONS
Thank you for purchasing this Panasonic product.
Please read these instructions carefully before attempting to install, operate or service
the Panasonic product. Please carefully read the GENERAL SAFETY INFORMATION
Failure to comply with instructions could result in personal injury or property damage.
Please explain to users how to operate and maintain the product after installation,
and this booklet should be presented to users.
Please retain this booklet for future reference.
Representative models:
FV-0511VQL1
FV-1115VQL1
FV-0511VQCL1
Ventilating Fan
FV-1115VQL1
FV-0511VQCL1
Model No.
FV-0511VQL1
Contents
GENERAL SAFETY INFORMATION
DESCRIPTION
UNPACKING
SUPPLIED ACCESSORIES
DIMENSIONS
WIRING DIAGRAM
SELECTOR INDICATION (FV-0511VQCL1 only)
OPERATION (FV-0511VQCL1 only)
FEATURE
INSTALLATION (NEW CONSTRUCTION)
INSTALLATION (RETROFIT)
MAINTENANCE (CLEANING)
PRACTICAL GUIDE TO INSTALLATION
SPECIFICATIONS
PRODUCT SERVICE
--------------2~3
----------------------------------------4
-----------------------------------------4
--------------------------4
-----------------------------------------5
-----------------------------------6
---------6
-----------------7
---------------------------------------------7
--------8~9
-----------------------10
------------------10~11
-----------11
-----------------------
------------ 11
--------------------
BACK COVER
1 1 Q C L 1 4 2 0 B
English
To reduce the risk of injury, loss of life, electric shock, re, malfunction, and damage to
equipment or property, always observe the following safety precautions.
Denotes a potential hazard that could result in serious
injury or death.
Denotes a hazard that could result in minor injury.
The following symbols are used to classify and describe the type of instructions to be observed.
This symbol is used to alert users to a specic operating procedure that must not be
performed.
This symbol is used to alert users to a specic operating procedure that must be followed
in order to operate the unit safely.
WARNING
WARNING
The following symbol word panels are used to classify and describe the level of hazard, injury, and
property damage caused when the denotation is disregarded and improper use is performed.
CAUTION
This symbol is used to alert users not to disassemble the equipment.
This symbol is used to alert users to make sure of grounding when using the equipment
with the grounding terminal.
GENERAL SAFETY INFORMATION
Denotes a hazard that could result in property damage.
To reduce the risk of re, electric shock or injury to persons, observe the following :
Use this unit only in the manner intended by the manufacturer. If you have any questions,
contact the manufacturer.
Before servicing or cleaning unit, switch power o at service panel and lock the service
disconnecting means to prevent power from being switched on accidentally. When the
service disconnecting means cannot be locked, securely fasten a prominent warning device,
such as a tag, to the service panel.
Installation work and electrical wiring must be done by qualied person(s) in accordance with
all applicable codes and standards, including re-rated construction.
Sucient air is needed for proper combustion and exhausting of gases through the ue (chimney)
of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s
guideline and safety standards such as those published by the National Fire Protection Association
(NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers
(ASHRAE) and the local code authorities.
When cutting or drilling into wall or ceiling, do not damage electrical wiring and other
hidden utilities.
Ducted fans must always be vented to the outdoors.
If this unit is to be installed over a tub or shower, it must be marked as appropriate for the
application and be connected to a GFCI (Ground Fault Circuit Interrupter) - protected branch
circuit.
These models are UL listed for tub and shower enclosures.
2
NOTICE
For Your Safety
Explanation of symbol word panels
English
GENERAL SAFETY INFORMATION CONTINUED
CAUTION
Make sure that the electric service supply voltage is AC 120V, 60Hz.
Canada only: Not to be installed in a ceiling thermally insulated to a value greater than R40.
Do not disassemble the unit for reconstruction. It may cause re or electric shock.
Ceiling joist must be subjected to static load more than ve times the weight of the product.
Install the fan at least 1.5m(5feet) above the oor, and the fan must be installed above a
counter or major appliances that serves as a barrier.
A statement to the eect that when the product is to no longer be used, it must not be left
in place but remove, to prevent it from possibly failing.
Do not install with a method which is not approved in the instructions.
Do not install this ventilating fan where interior room temperature may exceed 104°F (40°C)
This product must be properly grounded.
Do not use this fan with any solid-state speed control device. Solid state controls may cause
harmonic distortion which can cause motor humming noise.
Follow all local electrical and safety codes, as well as the National Electrical Code (NEC) and
the Occupation Safety and Health Act (OSHA).
Always disconnect the power source before working on or near the fan,motor or junction box.
Protect the supply wiring from sharp edges oil, grease, hot surfaces, chemicals or other objects.
Do not kink the supply wiring.
Not for use in cooking area. (Fig.A)
The special-purpose or dedicated parts, such as mounting
xtures, must be used if such parts are provided.
For general ventilating use only. Do not use to exhaust hazardous
or explosive materials and vapors.
Floor
45°
4
Cooking
equipment
Fig. A
(Cooking area)
Do not install above or
inside this area
Provide make up air for proper ventilation.
Do not install the unit where ducts are congured as shown in below.
Bend close to duct adaptor
Squeezed ductSuccessive bendingExcessive bending
Adaptor
When one switch is connected with two or more products in parallel, the unit may not function.
Therefore, parallel connection should not be allowed.