Powerhouse 1000Wi Bruksanvisning
Powerhouse
Generator
1000Wi
Läs nedan 📖 manual på svenska för Powerhouse 1000Wi (38 sidor) i kategorin Generator. Denna guide var användbar för 4 personer och betygsatt med 4.5 stjärnor i genomsnitt av 2 användare
Sida 1/38
1000Wi Digital Inverter Generator
POWERHOUSE
POWERHOUSE
POWERHOUSE
POWERHOUSEPOWERHOUSE®
®
®
®®
OWNER ’S MANUAL
PLEASE READ THIS MANUAL
CAREFULLY BEFORE USING
2 1000Wi OM
Quick Start Guide
Use outdoors only. Generators produce carbon monoxide a poisonous, colorless, —
odorless gas that can cause death or serious injury.
Always operate on a level surface.
Keep away from rain, snow or other wet conditions.
Keep away from smoking materials, sparks, and other sources of combustion when
refueling.
Pre-Operation
1. Add oil by removing the maintenance panel and inspecting the dipstick. Fill the oil reservoir with 8.5 oz.
( ml) of oil or to the full mark on the dipstick. Use appropriate grade, high-detergent, premium quality, 250
4-stroke engine oil (synthetic or conventional) Use SAE 15W-40 viscosity oil unless operating at ambient .
temperatures below 32° F (0° C) For temperatures below 32° F, use SAE 0W- viscosity oil. Refer to the . 40
Operating at extreme temperatures section for more information.
2. Carefully add regular unleaded automotive gasoline up to the shoulder of the fuel strainer. To avoid spilling
fuel, use care to not ll too quickly or over ll. Avoid getting dirt, dust, or water in the fuel tank. Do not use a
blend that contains more than 10% ethanol. Do not use gasoline containing methanol. An octane rating of
87 or higher is recommended.
Do not add 2-Stroke oil to your fuel. Doing so will void your warranty.
It is recommended that you use a fuel stabilizer, such as STA- ®, to help prevent fuel BIL
oxidation (breakdown) and the formation of gum and varnish, and to inhibit corrosion in
the fuel system and carburetor.
Operation
1. Ensure that no loads have been connected to the AC receptacles.
2. Open the fuel valve.
3. Push the engine switch on the control panel to the . “ON” position
4. Move the choke lever to the START positi “ ” on.
5. Pull the starter grip lightly until resistance is felt, then pull briskly out. Repeat until the engine starts.
6. Move the choke lever to the RUN position after the engine warms up. “ ”
7. The green “RUN” light will illuminate when the generator is ready for use. Before connecting any loads,
ground the generator with a length of heavy cable, connecting the generator’s grounding terminal to an
external ground source.
8. Make sure that all appliances to be connected have been switched o and are in good working order.
Conrm that the combined electrical rating of the appliances does not exceed that of the generator.
9. Connect the appliance to the appropriate receptacle on the generator’s control panel.
10. To minimize fuel consumption and noise, push the economy switch to the “ON” position. This setting
regulates the engine’s speed so that it matches the needs of the connected loads. Do not use the economy
setting if you are connecting items with electric motors that have a high amperage draw during startup or
with appliances that cycle on and off rapidly.
Shutdown
In an emergency, pushing the Engine Switch on the control panel to the “OFF” position
will automatically stop the engine with or without a load. However, repeatedly stopping
the generator without disconnecting all loads can cause damage to the generator or
appliances.
1. Turn o all connected appliances and disconnect from the generator.
2. Push the engine switch on the control panel to the . “OFF” position
3. Turn the fuel valve o.
3 1000Wi OM
PREFACE
Thank you for purchasing a POWERHOUSE® generator.
This manual covers operation and maintenance of POWERHOUSE® generator model 1000Wi.
All information in this publication is based on the latest product information available at the time of printing.
We reserve the right to make changes at any time without notice and without incurring any obligation.
No part of this publication may be reproduced without written permission.
This manual should be considered a permanent part of the generator and should remain with it if it is resold.
Pay special attention to statements preceded by the following words:
Indicates a strong possibility of severe personal injury or death if instructions are not
followed.
Indicates a possibility of personal injury or equipment damage if instructions are not
followed.
Gives helpful information.
If you have a problem with this generator, do not return it to the store where you purchased it. For warranty
support call 877-544-4449 from 8am to 6pm ET, email us at warranty@powerhouse-products.com or send a
fax to -263-0280. 800
Failure to properly follow these precautions can result in property damage, serious injury,
or DEATH!
Read all labels and the Owner's Manual before operating this generator.
Generators produce carbon monoxide a poisonous, colorless, odorless gas that can —
cause death or serious injury.
Indoor use of a generator can kill quickly. Generators should be used outdoors only.
Generators should only be used outdoors away from garages and open windows, but
protected from rain and snow.
Check for spilled fuel or leaks. Clean and/or repair before use.
Always stop engine before refueling. Wait 5 minutes before restarting.
Keep any source of ignition away from fuel tank, at all times.
The portable generator is not meant to be used as a permanent back-up power system
for the home. A permanently installed stationary generator is designed to be safely used
for this specic purpose.
Our generators are designed to give safe and dependable service if operated according
to instructions. Read and understand the Owner's Manual before operating the
generator. Failure to do so could result in personal injury or equipment damage.
©Copyright DTS Manufacturing / The Coast Distribution System, Inc. 2012
Produktspecifikationer
Varumärke: | Powerhouse |
Kategori: | Generator |
Modell: | 1000Wi |
Behöver du hjälp?
Om du behöver hjälp med Powerhouse 1000Wi ställ en fråga nedan och andra användare kommer att svara dig
Generator Powerhouse Manualer
19 September 2024
19 September 2024
19 September 2024
19 September 2024
19 September 2024
19 September 2024
19 September 2024
19 September 2024
19 September 2024
19 September 2024
Generator Manualer
- Generator Bosch
- Generator Braun
- Generator Philips
- Generator DeWalt
- Generator Honeywell
- Generator Vetus
- Generator Eurom
- Generator Generac
- Generator Subaru
- Generator Gude
- Generator Makita
- Generator Domo
- Generator Rowenta
- Generator Stanley
- Generator Hyundai
- Generator Westinghouse
- Generator Moulinex
- Generator Taurus
- Generator Parkside
- Generator Sun Joe
- Generator Einhell
- Generator Voltcraft
- Generator Craftsman
- Generator Powerplus
- Generator Trotec
- Generator Scheppach
- Generator Honda
- Generator Bavaria
- Generator Simpson
- Generator Gys
- Generator Zipper
- Generator Harvia
- Generator Defort
- Generator Superior
- Generator Fuxtec
- Generator Truper
- Generator Cleanmaxx
- Generator Cocraft
- Generator Cecotec
- Generator Herkules
- Generator Toolcraft
- Generator Lumag
- Generator Telair
- Generator Endress
- Generator GW Instek
- Generator EcoFlow
- Generator Powerspot
- Generator Black Decker
- Generator SRS
- Generator Bluetti
- Generator Anova
- Generator Global
- Generator King Craft
- Generator AudioControl
- Generator Duromax
- Generator CrossTools
- Generator Jackery
- Generator Lifan
- Generator Rigol
- Generator Cleveland
- Generator Joy-it
- Generator Full Boar
- Generator Duro Pro
- Generator Alpha Tools
- Generator Powerkick
- Generator Könner & Söhnen
- Generator Load Up
- Generator PowerTech
- Generator Woods
- Generator A-iPower
- Generator Stromkraft
- Generator ITC Power
- Generator MSW
- Generator Ribimex
- Generator Arvey
- Generator Tektronix
- Generator PRAMAC
- Generator DuroStar
- Generator ThermaSol
Nyaste Generator Manualer
27 Oktober 2024
27 Oktober 2024
27 Oktober 2024
27 Oktober 2024
26 Oktober 2024
17 Oktober 2024
12 Oktober 2024
10 Oktober 2024
3 Oktober 2024
2 Oktober 2024