Sencor SWS 30 Bruksanvisning
Sencor
Väderstation
SWS 30
Läs nedan 📖 manual på svenska för Sencor SWS 30 (2 sidor) i kategorin Väderstation. Denna guide var användbar för 7 personer och betygsatt med 4.5 stjärnor i genomsnitt av 2 användare
Sida 1/2
RS8711ETC 1/2
Operation Instruction
一
一
一
一一, Main Functions:
1. Radio-controlled function
2. weather forecast for 4 states: sunny, semi-sunny, cloudy, rainy
3. seven languages to show the day: English, Germany, French, Italian, Spanish, Dutch, Danish
4. indoor temperature range: 0℃--50℃, sampling cycle: 12 seconds
℃--50℃, sampling cycle: 12 seconds
℃--50℃, sampling cycle: 12 seconds
℃--50℃, sampling cycle: 12 seconds℃--50℃, sampling cycle: 12 seconds
5. indoor humidity range: 20%-----95%
6. outdoor temperature with RF: up to 3 channels
7. in/out trend indication of temperature
8. indication of the comfort index
9. the function of Alarm/ Snooze
10. 12/24 hour selectable
11. moon phase
12. LED light
13. world time zone set, -12/+12 hours
二. Power-On and reset
1. When Power-On and reset, LCD full display for 3 seconds
enter the normal state after “Beep”
check temperature and humidity
2. The calendar defaults 0:00 January 1, 2004
3. Alarm defaults 0:00
4. The weather icon defaults semi-sunny
5. Temperature scales defaults Celius degree ℃
℃
℃
℃℃. Time system defaults 24Hr.
三
三
三
三三. instruction of operating the KEYS
3.1 Key functions
Six functional keys: Set, Alarm, Up, Down, Snooze, Channel
Clock Alarm Up Down SNZ/LIGHT Channel Alert Max/Min
standard mode
Click ----- Alarm
on/off
12hr/24hr
switchable
° °C/ F
switchable
Back Light/
enter Snooze
Switch to
CH1,CH2,CH3
On/Off
temperature
Alarm
Switchable
between
CH1, 2, 3
Hold enter into
clock setting
enter into
alarm setting
----- ----- ----- Clear
current
registered
Into
temperature
alarm setup
clear max/
min
Time set
Click Confirm the
setting item
----- one step
forward
one step
backward
----- --------- ---------- ----------
Hold ----------- ----- 8steps/second
forward
8steps/second
backward
----- --------- ----------- ----------
Alarm set
Click ---------- confirm the
setting item
one step
forward
One step
backward
----- --------- ------------ --------
Hold ---------- ----- 8steps/second
forward
8steps/second
backward
----- --------- ------------ -----
Temp alert set
Click
-----------
-----
one step
forward
one step
backward
-----
Choose
needed
channel
Confirm the
Setting item
---------
Hold
----------
------
8steps/second
forward
8steps/second
backward
-----
------
------
----------
3.2 Normal states
1. hold “clock” for 2 seconds to enter into time setting
2. click “Alarm” to switch the alarm on/off
3. hold “Alarm ” for 2 seconds to enter into Alarm setting
4. click “Up” to switch between 12hr/24hr
5. press “Down” to switch between °C/°F
6. press”SNZ/LIGHT”to turn on the back light 5 second
7. when ALARM rings, click “SNZ/LIGHT” to enter into the snooze state every 5 minutes
8. press “Channel” to switch RF channel, CH1
CH2 CH3
9. hold “Channel” key for 2 seconds to clear out all data of current “Channel”
10. press”ALERT”key to switch temperature alarm on/off
11. hold”ALERT”key 2 seconds to enter temperature alarm setting
12. press”MAX/MIN”key to check maximal and minimum of temperature and humidity
13. hold”MAX/MIN”key 2 seconds to clear all record of temperature and humidity
3.3 Time set
1. hold “clock” key for 2 seconds to enter into time setting
2. the sequence of time setting: Year(2000-2050)
Month
Date
Language
Hour
Minute
Time zone
Exit
Function
Operation
RS8711ETC 2/2
3. there will have 1Hz flashing during setting
4. press “clock” to confirm the setting, and enter the next setting state
5. press “Up” one time, the setting will go ahead for one step; hold the key for 2 seconds, it will run forward by 8 steps/second.
6. press “Down” one time, the setting will backward for one step; hold for 2 seconds, it will run back by 8 steps/second.
7. moon phase is changed accordingly time changed.
8. the system will exit automatically if no key is operated in 8 seconds.
3.4 Alarm set
1. hold “Alarm” key for 2 second to enter into alarm setting
2. the sequence of alarm setting: Hour
Minute
exit
3. there will have 1Hz flashing during setting
4. press “Alarm” to confirm the setting, and enter the next setting state
5. press “Up” one time, the setting will go ahead for one step; hold the keys for 2 seconds, it will run forward by 8 steps/seconds.
6. press “Down” one time, the setting will backward for one step; hold for 2 seconds, it will run back by 8 steps/second.
7. the system will exit automatically if no key is operated in 8 seconds.
3.5 Temperature alarm setting
1. hold”ALERT”2 second into ALERT setting
2. setting sequence :upper limited
lower limit
exit
3. press”CHANNEL”key when setting upper limited and lower limited to change different channel.
4. default of upper limited is:+70°C ,lower limited is -50°C
5. there will have 1Hz flashing during setting
6. press”ALERT”key confirm the end of setting then enter next item setting
7. press “Up” one time, the setting will go ahead for one step; hold the keys for 2 seconds, it will run forward by 8 steps/seconds.
8. press “Down” one time, the setting will backward for one step; hold for 2 seconds, it will run back by 8 steps/second.
9. the system will exit automatically if no key is operated in 8 seconds.
10. Alert will automatically turn on when setting is finish.
3.6 RCC receiving function:
1. How to enter RCC receiving status:
a. It will enter RCC receiving state automatically 3 minutes after powering ON or resetting.
b. It enters RCC receiving automatically at2:00, 3:00, 4:00, 5:00 everyday.
c. Press “Down” or “UP” key for 2 seconds to enter RCC receiving status forcibly.
2. RCC receiving time is 7 minutes.
3. When it is receiving signals, press “Down” or “UP” key will exit RCC receiving status, pressing any other key will have no effect.
4. When DST is able and is receiving the signal, it will display the symbol of sun on the LCD, showing that it enters the DST system, and the
time will be 1 hour faster.
5. When the RCC symbols display fully, the relative RCC icon will be OFF if the present time is changed.
四
四
四
四四. Function and effect
4.1 The receiving function of RF
1. after installing the battery and checking temperature/humidity, it will enter RF receiving state automatically for 3 minutes.
2. under normal display mode, hold the “Channel” key for 2 seconds to clear out the channel information
3. if there is no effective signal with same ID code received for the current channel in 35 minutes, the temperature of that CH will shows “--.-“.
4. the temperature display will resume back when the correct signal is received again
4.2 The function of alarm
1. the BUZZER will ring for 2 seconds as below:
a. 0 – 10 sec.: one “beep” per second
b. 10 – 20 sec.: two “beep” per second
c. 20 – 30 sec.: four “beep” per second
d. after 30 sec.: “beep” continuously
2. when ringing, click “SNZ/LIGHT” key once to enter into 5 minutes snooze states, exit if any other key is clicked.
4.3 The function of temperature and humidity
1. the indoor temperature display range: 0℃
℃
℃
℃℃ -- +50℃
℃
℃
℃℃ (32F -- +122F)
2. the indoor temperature proposed operating range: 0℃
℃
℃
℃℃ -- +40℃
℃
℃
℃℃ (32F -- +104F)
3. the outdoor temperature display range: - 50℃
℃
℃
℃℃ -- +70℃
℃
℃
℃℃ (-58F -- +158F)
4. the outdoor temperature proposed operating range: -5℃
℃
℃
℃℃ -- +45℃
℃
℃
℃℃ (23F -- +113F)
5. the temperature resolution: 0.1℃
℃
℃
℃℃
6. the indoor humidity range: 20% --- 95%
7. the humidity resolution: 1%RH
8. sampling period: 12 seconds.
9. the temperature and hygrometer sampling will be held when the alarm is ringing
10. the RF Transmission Frequency: 433.92MHz
11. No. of Remote unit: Up to 3units
4.4 The function of weather forecast
1. weather icons for 4 states: sunny
semi-sunny
cloudy
rainy
Produktspecifikationer
Varumärke: | Sencor |
Kategori: | Väderstation |
Modell: | SWS 30 |
Behöver du hjälp?
Om du behöver hjälp med Sencor SWS 30 ställ en fråga nedan och andra användare kommer att svara dig
Väderstation Sencor Manualer
5 Oktober 2024
3 Oktober 2024
24 September 2024
24 September 2024
24 September 2024
24 September 2024
24 September 2024
24 September 2024
24 September 2024
24 September 2024
Väderstation Manualer
- Väderstation Braun
- Väderstation Daewoo
- Väderstation Honeywell
- Väderstation Ade
- Väderstation Alecto
- Väderstation Ascot
- Väderstation Lexibook
- Väderstation Nedis
- Väderstation Pyle
- Väderstation Taylor
- Väderstation Livoo
- Väderstation OBH Nordica
- Väderstation Hyundai
- Väderstation Renkforce
- Väderstation ECG
- Väderstation Clatronic
- Väderstation Lowrance
- Väderstation Blaupunkt
- Väderstation Elro
- Väderstation EMOS
- Väderstation Extech
- Väderstation Denver
- Väderstation Hama
- Väderstation Cresta
- Väderstation Brigmton
- Väderstation Velleman
- Väderstation GlobalTronics
- Väderstation La Crosse Technology
- Väderstation GoGEN
- Väderstation AcuRite
- Väderstation Muse
- Väderstation Auriol
- Väderstation Ventus
- Väderstation Technoline
- Väderstation Cotech
- Väderstation Davis
- Väderstation Netatmo
- Väderstation Bresser
- Väderstation TFA
- Väderstation Clas Ohlson
- Väderstation Irox
- Väderstation Konig
- Väderstation Trevi
- Väderstation Orion
- Väderstation EVE
- Väderstation UPM
- Väderstation Fluke
- Väderstation Minox
- Väderstation Gira
- Väderstation Jung
- Väderstation Krontaler
- Väderstation Balance
- Väderstation Day
- Väderstation ELV
- Väderstation Dexford
- Väderstation EQ3
- Väderstation Saxon
- Väderstation IT
- Väderstation Garni
- Väderstation HomeMatic
- Väderstation Eurochron
- Väderstation La Crosse
- Väderstation Durabase
- Väderstation Meade
- Väderstation Brandson
- Väderstation Levenhuk
- Väderstation Digi-tech
- Väderstation Oregon Scientific
- Väderstation Unitec
- Väderstation TFA Dostmann
- Väderstation Greisinger
- Väderstation Ease Electronicz
- Väderstation Rebel
- Väderstation Mebus
- Väderstation Saphir
- Väderstation Paget Trading
- Väderstation PeakTech
- Väderstation Chauvin Arnoux
- Väderstation Techno Line
- Väderstation Uzoli
- Väderstation Xeecom ApS
- Väderstation Marathon
- Väderstation Ea2 LABS
- Väderstation Hesdo
- Väderstation Weinberger
- Väderstation Majestic
- Väderstation EMOS SELECT
- Väderstation Prologue
- Väderstation Gewiss
- Väderstation National Geographic
- Väderstation Browin
- Väderstation ClimeMET
- Väderstation Thierry Mugler
- Väderstation Otio
- Väderstation Baldr
- Väderstation Setti+
- Väderstation Bearware
Nyaste Väderstation Manualer
20 Oktober 2024
18 Oktober 2024
15 Oktober 2024
8 Oktober 2024
6 Oktober 2024
5 Oktober 2024
5 Oktober 2024
4 Oktober 2024
4 Oktober 2024
3 Oktober 2024