Siemens SITOP UPS1100 Bruksanvisning
Läs nedan 📖 manual på svenska för Siemens SITOP UPS1100 (2 sidor) i kategorin UPS. Denna guide var användbar för 8 personer och betygsatt med 4.5 stjärnor i genomsnitt av 2 användare
Sida 1/2
© Siemens AG 2013. All rights reserved
C98130-A7623-A1-3-6419, 08.2013
SITOP UPS1100
SITOP UPS1100
SITOP UPS1100
SITOP UPS1100 SITOP UPS1100
Batteriemodul 1,2 Ah
Batteriemodul 1,2 Ah
Batteriemodul 1,2 Ah
Batteriemodul 1,2 Ah Batteriemodul 1,2 Ah
6EP4131-0GB00-0AY0
6EP4131-0GB00-0AY0
6EP4131-0GB00-0AY0
6EP4131-0GB00-0AY0 6EP4131-0GB00-0AY0
Batteriemodul 3,2 Ah
Batteriemodul 3,2 Ah
Batteriemodul 3,2 Ah
Batteriemodul 3,2 Ah Batteriemodul 3,2 Ah
6EP4133-0GB00-0AY0
6EP4133-0GB00-0AY0
6EP4133-0GB00-0AY0
6EP4133-0GB00-0AY0 6EP4133-0GB00-0AY0
Batteriemodul 7 Ah
Batteriemodul 7 Ah
Batteriemodul 7 Ah
Batteriemodul 7 Ah Batteriemodul 7 Ah
6EP4134-0GB00-0AY0
6EP4134-0GB00-0AY0
6EP4134-0GB00-0AY0
6EP4134-0GB00-0AY0 6EP4134-0GB00-0AY0
Operating Instructions (compact)
Bild 1: Ansicht Geräte
Figure 1: View of the devices
Figure 1: Vue des appareils
Figura 1: Vista degli apparecchi
Figura 1: Vista de aparatos
Bild 2: Montage 1,2 Ah
Figure 2: Mounting 1.2 Ah
Figure 2: Montage 1,2 Ah
Figura 2: Montaggio 1,2 Ah
Figura 2: Montaje 1,2 Ah
ENGLISH
ENGLISH
ENGLISH
ENGLISH ENGLISH
Description
Description
Description
Description Description
The 24 V/1.2 Ah, 3.2 Ah or 7 Ah battery
module has 2x maintenance-free, sealed
lead AGM rechargeable batteries as well
as terminals for the connecting cables to
the uninterruptible power supply SITOP
UPS1600.
degree of protection IP20 according to
EN 60529
See Figure 1 View of the devices (Page 1)
Safety notes
Safety notes
Safety notes
Safety notesSafety notes
NOTICE
NOTICE
NOTICE
NOTICE NOTICE
The fuses should only be inserted in the
fuse holder when commissioning the
device.
When replacing the rechargeable
batteries, always use batteries with the
same batch number. (approximately the
same charge state).
The rechargeable batteries must be
disposed of, discharged according to the
applicable regulations.
When storing, installing and operating
the buffer batteries, the regulations of
VDE 0510 Part 2 / EN 50272-2 or the
applicable national regulations must be
complied with.
It must be ensured that the battery
location is suitably ventilated.
Location of the battery module: In the
lower part of the control cabinet or at the
coolest location in the control cabinet.
Only qualified personnel are allowed to
install the device/system and set it into
operation.
Assembling
Assembling
Assembling
Assembling Assembling
Direct wall mounting
or
DIN EN 60715-TH35-15/7,5 for 1.2 Ah
or
DIN EN 60715-TH35-15 for 3.2 Ah
The device must be mounted in such a
way that the input and output terminals
are at the bottom.
A clearance of at least 50 mm must be
maintained above and below the device.
See Figure 2 Mounti 1) ng 1.2 Ah (Page
See Figure 3 Mounti 2) ng 3.2 Ah (Page
See Figure 4 Mounti 2) ng 7 Ah (Page
Bild 3: Montage 3,2 Ah
Figure 3: Mounting 3.2 Ah
Figure 3: Montage 3,2 Ah
Figura 3: Montaggio 3,2 Ah
Figura 3: Montaje 3,2 Ah
Bild 4: Montage 7 Ah
Figure 4: Mounting 7 Ah
Figure 4: Montage 7 Ah
Figura 4: Montaggio 7 Ah
Figura 4: Montaje 7 Ah
Bild 5: Input/Output 1,2 Ah
Figure 5: Input/output 1.2 Ah
Figure 5: Entrée/sortie 1,2 Ah
Figura 5: Input/Output 1,2 Ah
Figura 5: Entrada/salida 1,2 Ah
Connecting
Connecting
Connecting
Connecting Connecting
For installation of the devices, the
relevant country-specific regulations
must be observed.
See Figure 5 Input/output 1.2 Ah (Page 2)
See Figure 6 Input/output 7 Ah (Page 3)
See Figure 7 Terminal data 1.2 Ah/3.2 Ah
(Page 3)
See Figure 8 Terminal data 7 Ah (Page 3)
Structure
Structure
Structure
Structure Structure
①DC input X1
②Signal terminal X2
③Fuses F1/F2 (F2 only for 7 Ah)
④Signaling (LED)
⑥Screws for battery replacement
(Torx T10)
See Figure 5 Input/output 1.2 Ah (Page 2)
See Figure 6 Input/output 7 Ah (Page 3)
Battery
Battery
Battery
Battery Battery
2x maintenance-free lead AGM
rechargeable batteries
12 V/1.2 Ah: Type: YUASA NP1.2-12
12 V/3.2 Ah: Type: YUASA NP3.2-12 or
B.B.Battery BP3.6-12
12 V/7 Ah: Type: YUASA NP7-12 or
B.B.Battery BP7-12
Battery replacement
● Remove the fuse
● Release the screws ⑥, open the
cover
● on for at least 2sPress the reset butt
(LED flashes)
● Replacing the battery
● on for at least 2sPress the reset butt
● Close the cover (screw)
● Insert the fuse
See Figure 9 Reset (Page 3)
See Figure 10 Wiring schematic
(Page 4)
The self-discharge rates of the
rechargeable batteries is approx.
3%/month for a temperature of 20 °C.
This value is temperature dependent,
and for an increasing temperature,
becomes more unfavorable and for a
decreasing temperature, more favorable.
C98130-A7623-A1-3-6419, 08.2013
Bild 6: Input/Output 7 Ah
Figure 6: Input/output 7 Ah
Figure 6: Entrée/sortie 7 Ah
Figura 6: Input/Output 7 Ah
Figura 6: Entrada/salida 7 Ah
$:*
1P
6=6[
[PP
[PP
1P
PP
1P
[PP
[PP
PP
6=6[
Bild 7: Klemmdaten 1,2 Ah/3,2 Ah
Figure 7: Terminal data 1.2 Ah/3.2 Ah
Figure 7: Caractéristiques des bornes 1,2 Ah/3,2 Ah
Figura 7: Dati dei morsetti 1,2 Ah/3,2 Ah
Figura 7: Datos de bornes 1,2 Ah/3,2 Ah
$:*
1P
6=6[
[PP
[PP
1P
PP
1P
[PP
[PP
PP
6=6[
Bild 8: Klemmdaten 7 Ah
Figure 8: Terminal data 7 Ah
Figure 8: Caractéristiques des bornes 7 Ah
Figura 8: Dati dei morsetti 7 Ah
Figura 8: Datos de bornes 7 Ah
Bild 9: Reset
Figure 9: Reset
Figure 9: Reset
Figura 9: Reset
Figura 9: Reset
Technical data
Technical data
Technical data
Technical data Technical data
Input variables
Input variables
Input variables
Input variablesInput variables
Rated input voltage Ue rated: 24 V DC
Input voltage range:
21 to 29 V DC
Output variables
Output variables
Output variables
Output variablesOutput variables
Rated output current I
a rated:
UPS1100 1.2 Ah: 10 A
UPS1100 3.2 Ah: 20 A
UPS1100 7 Ah: 40 A
Backup
Backup
Backup
BackupBackup
Flat fuse 15 A (provided in the packet of
accessories) for the 1.2 Ah rechargeable
battery
Flat fuse 25 A (provided in the packet of
accessories) for the 3.2 Ah or 7 Ah
rechargeable battery (2x)
Ambient conditions
Ambient conditions
Ambient conditions
Ambient conditionsAmbient conditions
Temperature for operation:
0… +40 °C
Temperature for operation:
-20… +50 °C
Pollution degree 2
Natural convection
Connectio
Connectio
Connectio
ConnectioConnections
ns
ns
nsns
2 pin screw terminals X1
2 pin screw terminals X1
2 pin screw terminals X1
2 pin screw terminals X12 pin screw terminals X1
2x connections, rechargeable battery
(+Bat and -Bat)
2 pin screw terminals X2
2 pin screw terminals X2
2 pin screw terminals X2
2 pin screw terminals X22 pin screw terminals X2
2x signal connections
See Figure 7 Terminal data
1.2 Ah/3.2 Ah (Page 3)
see Figure 8 Terminal data 7 Ah
(Page 3)
See also Figure 5 Input/output 1.2 Ah
(Page 2)
See also Figure 6 Input/output 7 Ah
(Page 3)
Dimensions
Dimensions
Dimensions
DimensionsDimensions
1.2 Ah:
1.2 Ah:
1.2 Ah:
1.2 Ah:1.2 Ah:
width × height × depth in mm:
89 × 130 × 107
3.2 Ah:
3.2 Ah:
3.2 Ah:
3.2 Ah:3.2 Ah:
width × height × depth in mm:
190 × 169 × 79
7 Ah:
7 Ah:
7 Ah:
7 Ah:7 Ah:
width × height × depth in mm:
186 × 186 × 110
+ +
++
+ +
++
(3*%$<$K
(3*%$<$K
(3*%$<$K
Bild 10: Verdrahtungsschema
Figure 10: Wiring schematic
Figure 10: Schéma de câblage
Figura 10: Schema di cablaggio
Figura 10: Esquema de cableado
Weight
Weight
Weight
WeightWeight
1.2 Ah
1.2 Ah
1.2 Ah
1.2 Ah1.2 Ah: 1.9 kg
3.2 Ah
3.2 Ah
3.2 Ah
3.2 Ah3.2 Ah: 3.8 kg
7 Ah
7 Ah
7 Ah
7 Ah7 Ah: 6.1 kg
Accessories
Accessories
Accessories
Accessories Accessories
SITOP UPS1600
www.siemens.com/sitop
Service and Support
Service and Support
Service and Support
Service and Support Service and Support
You can obtain additional information
through the homepage
www.siemens.de/sitop/manuals
http://support.automation.siemens.com
telephone: + 49 (0) 911 895 7222
Produktspecifikationer
Varumärke: | Siemens |
Kategori: | UPS |
Modell: | SITOP UPS1100 |
Behöver du hjälp?
Om du behöver hjälp med Siemens SITOP UPS1100 ställ en fråga nedan och andra användare kommer att svara dig
UPS Siemens Manualer
19 Augusti 2024
UPS Manualer
- UPS AEG
- UPS IKEA
- UPS HP
- UPS Apc
- UPS LC-Power
- UPS Tripp Lite
- UPS Energenie
- UPS Voltcraft
- UPS Emerson
- UPS Adj
- UPS Digitus
- UPS LevelOne
- UPS Eaton
- UPS Jung
- UPS CyberPower
- UPS Block
- UPS Avocent
- UPS Minuteman
- UPS Maruson
- UPS V7
- UPS Salicru
- UPS Equip
- UPS Approx
- UPS SurgeX
- UPS Murr Elektronik
- UPS Altronix
- UPS Ditek
- UPS Bxterra
- UPS Middle Atlantic
- UPS FSP
- UPS Atlantis Land
- UPS PowerWalker
- UPS FSP/Fortron
- UPS Online USV
Nyaste UPS Manualer
24 Oktober 2024
22 Oktober 2024
22 Oktober 2024
22 Oktober 2024
20 Oktober 2024
18 Oktober 2024
18 Oktober 2024
13 Oktober 2024
13 Oktober 2024
13 Oktober 2024