Softing CTK1015 Bruksanvisning

Läs nedan 📖 manual på svenska för Softing CTK1015 (2 sidor) i kategorin Inte kategoriserad. Denna guide var användbar för 2 personer och betygsatt med 4.5 stjärnor i genomsnitt av 2 användare

Sida 1/2
PORT IDENTIFICATION
Connect the Model 10 to a wall outlet,
select “Port ID” and then go to the hub or
switch connected to the wall outlet. The Link
light for the port connected to the wall outlet will
blink at a rate similar to the pattern selected on
the Model 10. Three patterns are provided.
SHORT CIRCUIT TEST
Connect the Model 10 to a cable with the
test leads and select Short”. If a short is
detected, the LED will stay on continuously
otherwise the LED will blink. The short circuit
test is available on pins 4,5 of the RJ-45 jack.
BATTERY LIFE
Auto Power Down - The Model 10 will
automatically turn off after approximately 20
minutes of operation.
Low Battery - When the battery is below the
level required for the Model 10 to operate
properly, the “LoBatt indicator illuminates.
WARRANTY
Psiber Data Systems Inc. warrants that the product shall be free from
defects in parts or workmanship for a period of 12 months from the date of
purchase if used in accordance with Psiber Data Systems Inc. operating
specifications.
THIS IS THE ONLY WARRANTY MADE BY Psiber Data
Systems Inc. AND IS EXPRESSLY MADE IN LIEU OF ALL OTHER
WARRANTIES EXPRESSED OR IMPLIED, INCLUDING BUT NOT
LIMITED TO ANY IMPLIED WARRANTIES OF MERCHANTABILITY
OR FITNESS FOR ANY PARTICULAR PURPOSE.
Should any parts or workmanship prove defective, Psiber Data Systems
Inc. will repair or replace at Psiber Data Systems’ option, at no cost to the
Buyer except for shipping costs from the Buyer’s location to Psiber Data
Systems Inc. This is Buyer’s SOLE AND EXCLUSIVE REMEDY under
this Agreement. This warranty does not apply to products which have been
subject to neglect, accident or improper use, or to units which have been
altered or repaired by other than an authorized repair facility.
Return of Equipment - To return a product to Psiber Data Systems Inc.,
first obtain a Return Authorization number from our Customer Service by
calling 619-287-9970. The RA# must be clearly marked on the shipping
label, or the package will not be accepted by Psiber Data Systems Inc.
Send To: Psiber Data Sytems Inc.
7075-K Mission Gorge Road
San Diego, CA 92120
RA# XXXXXXXX
CableTracker, psiber and the Psiber logo are trademarks of Psiber Data
Systems Inc. Copyright 2002 Psiber Data Systems Inc. All rights reserved.
Part No. 1005-1015-0000 Rev A
CABLETRACKER
NETWORK ID KIT
USER’S GUIDE
CONTENTS
Model 10 Signal Generator User Guide
Model 15 Probe RJ-45 Patch Cable
Red/Black Alligator Test Leads
Carrying Case (CTK1015 Kit Only)
BATTERY
The CableTracker Model 10 Signal
Generator and Model 15 Probe require one 9
volt alkaline battery each. Remove the battery
cover at the back of the unit, connect the
battery to the battery snap cable, insert the
battery in the battery well and replace the
battery cover.
OVERVIEW
The CableTracker Network ID Kit uses
two different techniques to identify network
cables and terminations. The Model 10 Signal
Generator transmits a trace tone on the cable
that is detected with the Model 15 Probe. When
the Probe is near the correct cable pair or
punchdown it indicates detection by emitting an
audible signal at the frequency and with the
same pattern that is selected on the Signal
Generator. The Model 10 Signal Generator will
identify the port connection on a switch or hub
by transmitting Link pulses to the device. The
Link light for the connected port blinks at a rate
similar to the transmitted Link pulse.
CONNECTION
Connect the Model 10 Signal Generator to
an unterminated cable pair using the red and
black test leads or to a wall outlet using the
RJ-45 patch cable. The Model 10 transmits
tone signals through the the test leads or the
RJ-45 jack. Link pulses for Port Identification
are only transmitted through the RJ-45 jack. An
RJ-11 patch cable can be connected to the RJ-
45 jack and the tone is transmitted on pair 4,5.
OPERATION
The Model 10 Signal Generator features
one button operation. Each press of the TEST
button advances the operating mode of the unit.
The modes are selected in the following order:
1. Low Frequency Tone Pattern 1
2. Low Frequency Tone Pattern 2
3. High Frequency Tone Pattern 1
4. High Frequency Tone Pattern 2
5. Link Light Pattern 1
6. Link Light Pattern 2
7. Link Light Pattern 3
8. Short Circuit Detection Test
9. Off
CABLE TRACING
Connect the Model 10 Signal Generator to
a cable or outlet, select either “LoTone” or
“HiTone” and turn on the Model 15 Probe by
pressing and holding the button. Place the probe
tip near the cable or termination to be identified
and the Probe emits an audible signal. The
audible signal is loudest when the Probe is near
the correct cable or termination point. The
volume can be adjusted by rotating the
thumbwheel located above the button. A red
light from the light pipe indicates that the unit is
on and the battery has adequate voltage.

Produktspecifikationer

Varumärke: Softing
Kategori: Inte kategoriserad
Modell: CTK1015

Behöver du hjälp?

Om du behöver hjälp med Softing CTK1015 ställ en fråga nedan och andra användare kommer att svara dig




Inte kategoriserad Softing Manualer

Softing

Softing CT15 Bruksanvisning

11 September 2024
Softing

Softing CTK1015 Bruksanvisning

11 September 2024

Inte kategoriserad Manualer

Nyaste Inte kategoriserad Manualer