Testo 835-T2 Bruksanvisning
Testo
Termometer
835-T2
Läs nedan 📖 manual på svenska för Testo 835-T2 (2 sidor) i kategorin Termometer. Denna guide var användbar för 2 personer och betygsatt med 4.5 stjärnor i genomsnitt av 2 användare
Sida 1/2
1 2
Element Function
1
1
1
1 1 Infrared lens IR measurement
2
2
2
2 2 4-point laser Measuring spot marking
3
3
3
3 3 Humidity probe (only H1) Measures the relative humidity
4
4
4
4 4 Trigger
Trigger
Trigger
Trigger Trigger - Switches the instrument on.
- Starts / ends a measurement.
5
5
5
5 5 Battery compartment Contains 3x AA batteries.
6
6
6
6 6 USB interface / probe
connection socket
- For connecting the instrument to the PC to
connect to the EasyClimate software.
- Connection of a probe.
7
7
7
7 7 - Joystick for confirming a selection.
- For navigating in the menu
8
8
8
8 8 ESC
ESC
ESC
ESC ESC Takes the user a step back in the menu selection.
9
9
9
9 9 Switches the testo 835 on or off.
10
10
10
10 10 Saves the measured readings.
11
11
11
11 11 Setting emissivity
12
12
12
12 12 HOLD
HOLD
HOLD
HOLDHOLD / SCAN
SCAN
SCAN
SCANSCAN - Scan: while the trigger is held down and the
measurement is carried out.
- Hold: displays the measured values.
13
13
13
13 13 Time Displays the current time.
14
14
14
14 14 Reading display Displays the measured readings.
Max
Max
Max
Max Max
[°C/°F]
[°C/°F]
[°C/°F]
[°C/°F] [°C/°F]
Min
Min
Min
Min Min
Surface temperature (IR)
Surface temperature (IR)
Surface temperature (IR)
Surface temperature (IR)Surface temperature (IR)
Max. IR temperature
IR temperature
Min. IR temperature
[°C/°F]
[°C/°F]
[°C/°F]
[°C/°F] [°C/°F]
Differential (surface temperat
Differential (surface temperat
Differential (surface temperat
Differential (surface temperatDifferential (surface temperature - external probe
ure - external probe
ure - external probe
ure - external probeure - external probe
temperature)
temperature)
temperature)
temperature)temperature)
TC temperature
IR temperature
Temperature difference TC / IR measurement
TC probe must be connected.
[%RH]
[%RH]
[%RH]
[%RH][%RH]
[°C/°F]
[°C/°F]
[°C/°F]
[°C/°F][°C/°F]
[°Ctd/°Ftd])
[°Ctd/°Ftd])
[°Ctd/°Ftd])
[°Ctd/°Ftd]) [°Ctd/°Ftd])
Humidity measurement (e
Humidity measurement (e
Humidity measurement (e
Humidity measurement (eHumidity measurement (environment + de
nvironment + de
nvironment + de
nvironment + denvironment + dewpoint +
wpoint +
wpoint +
wpoint + wpoint +
IR)
IR)
IR)
IR)IR) (only H1)
Ambient humidity
IR temperature
Ambient dewpoint temperature
Element Function
[%RH]
[%RH]
[%RH]
[%RH][%RH]
[°C/°F]
[°C/°F]
[°C/°F]
[°C/°F][°C/°F]
[°Ctd/°Ftd])
[°Ctd/°Ftd])
[°Ctd/°Ftd])
[°Ctd/°Ftd]) [°Ctd/°Ftd])
Humidity measurement (environment an
Humidity measurement (environment an
Humidity measurement (environment an
Humidity measurement (environment anHumidity measurement (environment and
d
d
d d
dewpoint) – ambient temperature
dewpoint) – ambient temperature
dewpoint) – ambient temperature
dewpoint) – ambient temperaturedewpoint) – ambient temperature (only H1)
Ambient humidity
Ambient temperature
Ambient dewpoint temperature.
Max
Max
Max
MaxMax
[°CDtd/°FDtd]
[°CDtd/°FDtd]
[°CDtd/°FDtd]
[°CDtd/°FDtd] [°CDtd/°FDtd]
Min
Min
Min
Min Min
Dewpoint distance measuremen
Dewpoint distance measuremen
Dewpoint distance measuremen
Dewpoint distance measuremenDewpoint distance measurement
t
t
t t (only H1)
Temperature difference IR minus dewpoint max
current
min.
Max
Max
Max
MaxMax
aw[-]
aw[-]
aw[-]
aw[-]aw[-]
Min
Min
Min
Min Min
Surface moisture measurement
Surface moisture measurement
Surface moisture measurement
Surface moisture measurementSurface moisture measurement (only H1)
Surface moisture max.
current
min.
Calculated from dewpoint, ambient air and
surface temperature
- 0.00 - 0.64: non-critical
- 0.65 - 0.80: poss. critical
- 0.81 - 1.00: critical
15
15
15
1515 Displays the battery charge status.
16
16
16
1616 Displayed if alarm is switched on.
17
17
17
1717 Displays the selected emissivity.
18
18
18
1818 Displayed if laser is switched on.
Connecting the thermocouple probe
Connecting the thermocouple probe
Connecting the thermocouple probe
Connecting the thermocouple probe Connecting the thermocouple probe
1
1
1
11 - Connect the connecting plug to the probe socket (6).
Switching the instrument on
Switching the instrument on
Switching the instrument on
Switching the instrument on Switching the instrument on
1
1
1
11 - Press (9).
- OR
- Press Trigger
Trigger
Trigger
TriggerTrigger (4).
Switching the instrument off
Switching the instrument off
Switching the instrument off
Switching the instrument off Switching the instrument off
1
1
1
11 - Hold down (9) until the display goes off.
If no button is pressed for 2 minutes, the instrument switches off
automatically.
3
Carrying out the measurement
Carrying out the measurement
Carrying out the measurement
Carrying out the measurement Carrying out the measurement
1
1
1
1 1 - Hold down Trigger
Trigger
Trigger
TriggerTrigger (4).
2
2
2
2 2 - Release Trigger
Trigger
Trigger
TriggerTrigger (4) to end the measurement.
3
3
3
3 3 - Move (7) up / down to change the reading display.
Making settings
Making settings
Making settings
Making settings Making settings
1
1
1
1 1 - Press (7) to open the menu.
2
2
2
2 2 - Move and press (7) to select the menu item.
3
3
3
3 3 - Moving and pressing (7) applies the settings.
Setting the emissivity
Setting the emissivity
Setting the emissivity
Setting the emissivity Setting the emissivity
Materials have various emissivities, i.e. they emit various amounts of
electromagnetic radiation. The emissivity of the instrument has a default
setting of 0.95. This is ideal for the measurement of non-metals (paper,
ceramic, gypsum, wood, paints and varnishes), plastics and foodstuffs.
1
1
1
1 1 - Press (11).
2
2
2
2 2 - For Customise
Customise
Customise
CustomiseCustomise manual
manual
manual
manual manual and Customise auto
Customise auto
Customise auto
Customise autoCustomise auto,
move (7) right to enter the emissivity.
For Customise auto
Customise auto
Customise auto
Customise autoCustomise auto, please refer to the instruction manual.
3
3
3
3 3 - Press (7) to confirm the selected emissivity.
Creating a storage location and saving readings
Creating a storage location and saving readings
Creating a storage location and saving readings
Creating a storage location and saving readings Creating a storage location and saving readings
1
1
1
1 1 - Press (10) to open the memory function.
2
2
2
2 2 - Select New Location
New Location
New Location
New LocationNew Location.
3
3
3
3 3 - Move (7) up / down or right / left to name the storage location.
4
4
4
4 4 - Confirm storage with .
Measuring lens
Measuring lens
Measuring lens
Measuring lens Measuring lens
(Ratio of distance: measuring range)
Depending on the distance of the measuring instrument from the measurement
object, a specific measuring range is recorded.
In italics = laser
Not in italics = measuring range
Managing the measurement data an
Managing the measurement data an
Managing the measurement data an
Managing the measurement data anManaging the measurement data and other measurement options
d other measurement options
d other measurement options
d other measurement options d other measurement options
Please download the free testo EasyClimate software for managing and archiving
your measurement data and for carrying out an online measurement.
You will find the link to download it here: www.testo.com/download-center
testo 835-H1
testo 835-H1
testo 835-H1
testo 835-H1 testo 835-H1
short instruction
short instruction
short instruction
short instruction short instruction
www.testo.com
www.testo.com
www.testo.com
www.testo.com www.testo.com
These brief instructions describe the basic operating steps. Please refer to
the instruction manual to find out how to handle the product safely and for
detailed information.
Produktspecifikationer
Varumärke: | Testo |
Kategori: | Termometer |
Modell: | 835-T2 |
Behöver du hjälp?
Om du behöver hjälp med Testo 835-T2 ställ en fråga nedan och andra användare kommer att svara dig
Termometer Testo Manualer
14 September 2024
14 September 2024
14 September 2024
11 September 2024
11 September 2024
11 September 2024
11 September 2024
11 September 2024
9 September 2024
9 September 2024
Termometer Manualer
- Termometer Braun
- Termometer Philips
- Termometer Inventum
- Termometer Motorola
- Termometer Quigg
- Termometer Topcom
- Termometer Ade
- Termometer AnD
- Termometer Amprobe
- Termometer Arendo
- Termometer ATN
- Termometer Aponorm
- Termometer Bartscher
- Termometer Kruidvat
- Termometer Orbegozo
- Termometer Telefunken
- Termometer Silvercrest
- Termometer Nedis
- Termometer Thomson
- Termometer Innoliving
- Termometer Pyle
- Termometer Taylor
- Termometer SereneLife
- Termometer Beurer
- Termometer Melissa
- Termometer Emerio
- Termometer Clatronic
- Termometer Sencor
- Termometer Lanaform
- Termometer Medisana
- Termometer Milwaukee
- Termometer Elro
- Termometer EMOS
- Termometer Extech
- Termometer Omron
- Termometer Citizen
- Termometer Hama
- Termometer Cresta
- Termometer Voltcraft
- Termometer Terraillon
- Termometer Velleman
- Termometer GlobalTronics
- Termometer La Crosse Technology
- Termometer Weber
- Termometer Marquant
- Termometer Kyoritsu
- Termometer IFM
- Termometer Flir
- Termometer Homedics
- Termometer Sanitas
- Termometer AcuRite
- Termometer Auriol
- Termometer Technoline
- Termometer Olympia
- Termometer Cotech
- Termometer Rossmax
- Termometer Vicks
- Termometer Microlife
- Termometer Welch Allyn
- Termometer Testboy
- Termometer Salter
- Termometer Trotec
- Termometer BabyOno
- Termometer Laica
- Termometer TFA
- Termometer Boso
- Termometer Clas Ohlson
- Termometer Powerfix
- Termometer Owon
- Termometer Irox
- Termometer Konig
- Termometer Reer
- Termometer Miniland
- Termometer Fluke
- Termometer Leifheit
- Termometer Etekcity
- Termometer Ecomed
- Termometer Laserliner
- Termometer Comark
- Termometer Fora
- Termometer Elta
- Termometer Zeiss
- Termometer Beaba
- Termometer Eurochron
- Termometer Medel
- Termometer Geratherm
- Termometer Truelife
- Termometer Bioland
- Termometer Global Tronics
- Termometer Oregon Scientific
- Termometer Levita
- Termometer Kerbl
- Termometer Scala
- Termometer Duronic
- Termometer Dittmann
- Termometer TFA Dostmann
- Termometer Greisinger
- Termometer CDN
- Termometer Emga
- Termometer Hartmann
- Termometer VDH
- Termometer Esperanza
- Termometer Uni-T
- Termometer Ebro
- Termometer Arya
- Termometer Bintoi
- Termometer PeakTech
- Termometer Elem6
- Termometer Thermoval
- Termometer Pasha
- Termometer Innovo
- Termometer Delta Ohm
- Termometer InfiRay
- Termometer Chauvin Arnoux
- Termometer PCE Instruments
- Termometer Joy-it
- Termometer Techno Line
- Termometer Klein Tools
- Termometer Knikker
- Termometer FlinQ
- Termometer AvaTemp
- Termometer EasyLife
- Termometer Alter
- Termometer TensCare
- Termometer Yummly
- Termometer Eks
- Termometer Gima
- Termometer Aspen
- Termometer Salva Tec
- Termometer Radiant
- Termometer Kuchenprofi
- Termometer WBTT
- Termometer Welby
- Termometer Prologue
- Termometer A&D
- Termometer ClimeMET
- Termometer Bearware
Nyaste Termometer Manualer
8 December 2024
8 December 2024
8 December 2024
8 December 2024
8 December 2024
8 December 2024
8 December 2024
8 December 2024
8 December 2024
8 December 2024