Vemer Celo LCD Bruksanvisning

Vemer Termostat Celo LCD

Läs nedan 📖 manual på svenska för Vemer Celo LCD (1 sidor) i kategorin Termostat. Denna guide var användbar för 8 personer och betygsatt med 4.5 stjärnor i genomsnitt av 2 användare

Sida 1/1
3
4
1User Manual
FLUSH-MOUNTING ELECTRONIC THERMOSTAT
Read all instructions carefully
DIMENSIONS
WIRING DIAGRAMS
LEGEND
2
40 42
40
L N
5A/250V~
V3IS01015-013 Mod. CELO LCD
Flush-mounting electronic thermostat for temperature control both in heating
and cooling. It performs actions of type 1B and are intended for operating
in environments with Pollution Degree 2 and Overvoltage Category III
(EN60730-1).
Code Model Description
VE780300 CELO LCD Flush-mounting thermostat - 2 modules 230 VAC
VE780301 CELO LCD-INT Flush-mounting thermostat - 2 modules 230 VAC
SAFETY WARNINGS
During product installation and operation it is necessary to observe the
following instructions:
1) The device must be installed by a qualified person, in strict compliance
with the connection diagrams.
2) Do not power or connect the device if any part of it is damaged
3) After installation, inacessibility to the connection terminals without
appropriate tools must be guaranteed.
4) The device must be installed and activated in compliance with current electric
systems standards.
5) Before accessing the connection terminals, verify that the leads are not live.
6) In the electrical system of the building where the device must be installed,
a protection device from the overcurrents must be present.
TECHNICAL SPECIFICATIONS
Power supply:
– 230Vac (-15% ÷ +10%) 50/60Hz
– max absorption: 6 VA / 230Vac
Installation on flush-mounting box with 45 mm height
Terminals:
– 3 terminals for 1.5 mm2 cables for bistable output relay 5A / 250 Vac
– 2 terminals for 1.5 mm2 cables for power supply
Summer/winter/off operating mode (with antifreeze)
Password protected lock keypad
Regulation type:
– on/off with settable differential (0.1 ÷ 1 °C)
– P8 proportional with 0.8°C band (-0.3 ÷ +0.5 °C) and period 8 minutes
– P15 proportional with 1.5°C band (-0.7 ÷ +0.8 °C) and period 15 minutes
Measurement precision: ± 0.5 °C
Measurement temperature resolution: 0.1 °C
Setpoint range: 2°C ÷ +50 °C
Operating temperature: 0 °C ÷ +50 °C
Storage temperature: -10 °C ÷ +65 °C
Operating humidity: 20÷90% non condensing
Protection degree: IP40
Insulation: reinforced among accessible parts (frontal) and all other terminals
Backlight: blue color
ADAPTERS FOR CIVIL SERIES PLATES FOR CELO LCD-INT
For information on the possibility of adapting the device with plates different from those
shown, contact the Technical Assistance Service.
Brand Series Adapter
ABB Mylos AM
AVE S44 A4
BTICINO
Axolute, Axolute AIR BA
Light, Living International,
LivingLight, LivingLight AIR BL
GEWISS Chorus GC
VIMAR Arkè, Eikon, Eikon Evo VE
Plana VP
“Environment temperature” field
“Off”
field
Heating - activation field
“Cooling - activation”
field
Key increases the selected field
Key decreases the selected field
Vemer S.p.A.
I - 32032 Feltre (BL) • Via Camp Lonc, 16
e-mail: info@vemer.it - web site: www.vemer.it
information to users pursuant to art. 14 of the directive
2012/19 / EU of the european parliament and of the council
of 4 july 2012 on waste electrical and electronic equipment (WEEE)
If the crossed-out bin symbol appears on the equipment or packaging,
this means the product must not be included wit h other general waste
at the end of its working life.
The user must take the worn product to a sorted waste center,
or return it to the retailer when purchasing a new one.
Products for disposal can be consigned free of charge (without any new purchase obligation)
to retailers with a sales area of at least 400 m
2, if they measure less than 25 cm.
An efficient sorted waste collection for the environmentally friendly disposal of the used device, or its
subsequent recycling, helps avoid the potential negative effects on the environment and people’s health,
and encourages the re-use and/or recycling of the construction materials.
5PLACEMENT
We recommend installing the device at a height of 1.5 meters from the floor,
in an area that reflects as much as possible the average temperature conditions
of the room.
Avoid installation near doors or windows, in niches, behind doors and curtains
or in positions with excess or total lack of ventilation.
Also make sure that the distance from the router is such as to ensure stable
communication.
REFERENCE STANDARDS
Compliance with Community Directives
2014/35/EU (LVD)
2014/30/EU (EMCD)
is declared with reference to the following harmonized standards:
• CEI EN 60730-2-9
01-2022
6a CELO LCD MOUNTING (code VE780300)
6b CELO LCD-INT MOUNTING (code VE780301)
Connect the load and power supply (see connection diagram)
Fasten the device with the metal frame to the flush mounting box and mount
the cover of the device (colour white / grey)
Apply the cover plate and the 50x50mm intermediate panel
Finally insert the closing frame (colour white / grey)
The device can be adapted to the cover plates of Berker, Busch-Jaeger, Gira, Jung
and Merten.
The complete list of compatible cover plates is available on the website
www.vemer.it on the product page.
Apply the adapter corresponding to the plate of the civil series to be mounted
(see table - Box 1)
Connect the load and the power supply (see connection diagram)
Insert the device into the adapter
DEVICE
WITH METALLIC FRAME
Flush-mounting box
Intermediate panel
(not supplied)
DEVICE
CLOSING FRAME
(WHITE / GREY)
Cover plate
(not supplied)
COVER
(COLOURS WHITE/GREY)
During the standard operation the thermostat displays the detected temperature value and the relay status is identified by the symbol (heating mode)
or the symbol (cooling mode).
Setpoint modification
Normal operation Modification of the desired temperature (setpoint),
to increase to decrease Normal operation heating on (
)
or
19.8
19.9
... 3 sec.
Error messages
Occurs for the following values of measured temperature:
t < 0 °C
t >50 °C (t > 60 °C with external probe)
Occurs in case of probe failure.
In this case the regulation is inhibited and
the relay contacts remain in position 2-3
Switch off
Note: in heating mode (winter), the device if off, it regulates according to the
antifreeze temperature Toff in order to prevent freezing of the system.
Toff can have values from 1 to 50° C or be excluded; in this case any minimum
temperature is guaranteed.
3 sec.
3 sec.
OPERATION
7
Advanced programming
To enter menu Advanced programming keep simultaneously
pressed for 3 seconds the keys
and
until will PR
appear. The items of the menu are displayed in succession.
For each item is displayed an identification abbreviation and
its relative blinking value.
Use the keys
and
to modify the value.
The passage to the next parameter occurs after 3 seconds
without pressing any key. Once all parameters are set the
writing is displayed and the thermostat returns to END
normal operation saving the effected modifications.
3 sec.
Minimum settable setpoint - L0
It’s the minimum value settable as setpoint.
Settable values: 2 ÷ 50 °C
Maximum settable setpoint - KI
It’s the maximum value settable as setpoint.
Settable values: ÷ 50 °CL0
Operating mode - E-I
if connected to the boiler (heating)
if connected to a cooling system
Antifreeze temperature - Toff - (only in heating)
Minimum temperature maintained with device off
(see box «Switch off»).
Settable values: 1 ÷ 50 °C or
--- (excluded function)
Regulation type - REG - (only in heating)
0 = on/off with settable differential
P8 = proportional with band 0.8°C and period 8 minutes
P15 = proportional with band 1.5°C and period 15 minutes
Differential - d0.3 - (only for on/off regulation)
Differential (or hysteresis) for temperature regulation.
Settable values: 0.1 ÷ 1 °C
Backlighting management
To turn the backlight off / on, press the button for 3 seconds.
In this condition the thermostat continues to operate normally
and the backlighting turns on when you enter setpoint modification menus,
advanced programming, pin enter.
3 sec.
3 sec.
Password for keypad lock - PAS
Set a value between 001 and 999 to activate the keypad lock.
Set --- to disable the lock.
If the keypad lock is active, pressing one key appearsLoC
and the password is required. If its properly inserted the
keyboard is unlocked for the next 30 seconds.
Reset
Default values
Heating setpoint 21 °C
Cooling setpoint 25 °C
Minimum settable setpoint - L0 2 °C
Maximum settable setpoint - Xi 50 °C
Operating mode (heating)
Antifreeze temperature 6 °C
Regulation type On /Off
Differential 0.3 °C
Password - - - (desabled)
Reset to delete the settings you made and reload the default values.
To reset:
1 remove and restore power to the device.
2 during the flashing of the backlighting press the keys
and
until DEf
will appear.
3 sec.

Produktspecifikationer

Varumärke: Vemer
Kategori: Termostat
Modell: Celo LCD

Behöver du hjälp?

Om du behöver hjälp med Vemer Celo LCD ställ en fråga nedan och andra användare kommer att svara dig




Termostat Vemer Manualer

Termostat Manualer

Nyaste Termostat Manualer