ELETTROVALVOLA A RIARMO MANUALE NORM. CHIUSA PER GAS
NORMALLY CLOSED MANUAL RESET SOLENOID VALVE FOR GAS
ÉLECTROVANNE A RÉARMEMENT MANUEL NORMALEMENT FERMÉE POUR GAZ
ELECTROVÁLVULA CON REARME MANUAL NORMALMENTE CERRADA PARA GAS
CE-51AT1438
MADE IN ITALY
IT EN FR ES
M14/RM N.C. - M14/RMC N.C.
M16/RMO N.C.
0497
0051
Omologazione CE secondo EN 161, conforme Regolamento (UE) 2016/426, Direttiva PED 2014/68/UE
EC approval according to EN 161, compliant with Regulation (EU) 2016/426, PED Directive 2014/68/EU
Homologation CE conformément à la norme EN 161, au Règlement (UE) 2016/426, Directive PED 2014/68/UE
Homologación CE según EN 161, conforme con el Reglamento (UE) 2016/426, Directiva PED 2014/68/UE
2
ITENFRES
INDICE - INDEX - INDEX ÍNDICE -
pag.
Italiano 3 ........................................................................................................................................................
English ........................................................................................................................................................13
Français 23 ......................................................................................................................................................
Español 33 .......................................................................................................................................................
Disegni - Drawings - Dessins - Diseños. 43 ...........................................................................................................
Dimensioni (tabella 1) 45 ...................................................................................................................................
Dimensions (table 1) .....................................................................................................................................
Dimensions (tableau 1) ..................................................................................................................................
Dimensiones (tabla 1) ....................................................................................................................................
Bobine e connettori di ricambio (tabella 2) 46 ........................................................................................................
Spare coils and connectors (table 2) ...............................................................................................................
Bobines et connecteurs de rechange (tableau 2) ...............................................................................................
Bobinas y conectores de recambio (tabla 2) ......................................................................................................
Diagramma - Diagram - Diagramme - Diagrama ∆p ............................................................................................ 47
13
IT
EN FR ES
1.0 - GENERAL INFORMATION
This manual shows you how to safely install, operate and use the device.
The instructions for use ALWAYS need to be available in the facility where the device is installed.
ATTENTION: installation/wiring/maintenance need to be carried out by qualified staff (as explained
in section 1.3) by using suitable personal protective equipment (PPE).
For any information pertaining to installation/wiring/maintenance or in any case problems that cannot be solved with the
instructions, contact the manufacturer by using the address and phone numbers provided on the last page.
1.1 - DESCRIPTION
Normally closed, manual reset solenoid valves for gas, suitable to shut off gas both to signal danger sent by gas detectors
(methane, LPG, carbon monoxide and similar) or safety thermostats, and in the event of a power cut.
For additional safety, this solenoid valve can only be reset with the power supply on and only when the gas detector is not
signalling danger.
IMPORTANT NOTE: The valve will not open by simply powering the coil. You must manually press the reset
mechanism (as indicated in 4.0).
Reference standards: EN 161 - EN 13611.
1.2 - KEY OF SYMBOLS
ATTENTION: Attention
is drawn to the technical
details intended for
qualified staff.
DANGER:
In the event of
inobservance, this may cause damage
to tangible goods, to people and/or pets.
DANGER: In the event
of inobservance, this may
cause damage to tangible
goods.
Produktspecifikationer
Varumärke: | Vemer |
Kategori: | Gasdetektor |
Modell: | VALV-1NC |
Behöver du hjälp?
Om du behöver hjälp med Vemer VALV-1NC ställ en fråga nedan och andra användare kommer att svara dig
Gasdetektor Vemer Manualer
2 September 2024
4 Augusti 2024
Gasdetektor Manualer
- Gasdetektor Abus
- Gasdetektor Alecto
- Gasdetektor AngelEye
- Gasdetektor Eminent
- Gasdetektor Elro
- Gasdetektor Techly
- Gasdetektor Kidde
- Gasdetektor Netatmo
- Gasdetektor FireAngel
- Gasdetektor First Alert
- Gasdetektor Fantini Cosmi
- Gasdetektor HQ
- Gasdetektor Nexa
- Gasdetektor Satel
- Gasdetektor Testo
- Gasdetektor ORNO
- Gasdetektor Itron
- Gasdetektor Vimar
- Gasdetektor Gloria
- Gasdetektor System Sensor
- Gasdetektor Pentatech
- Gasdetektor PCE Instruments
- Gasdetektor Joy-it
- Gasdetektor WisuAlarm
- Gasdetektor Schabus
- Gasdetektor Protector
- Gasdetektor Airthings
- Gasdetektor Deltronic
- Gasdetektor Gewiss
- Gasdetektor Figaro
- Gasdetektor GEV
Nyaste Gasdetektor Manualer
29 December 2024
28 December 2024
22 December 2024
16 December 2024
12 December 2024
25 Oktober 2024
22 Oktober 2024
26 September 2024
26 September 2024
24 September 2024