Well Health WH-OX01 Bruksanvisning
Well Health
WH-OX01
Läs nedan 📖 manual på svenska för Well Health WH-OX01 (37 sidor) i kategorin . Denna guide var användbar för 6 personer och betygsatt med 4.5 stjärnor i genomsnitt av 2 användare
Sida 1/37
English ..................................................................................................... 1
Nederlands .............................................................................................. 6
Français ................................................................................................. 11
Deutsch ................................................................................................. 16
Español .................................................................................................. 21
Italiano .................................................................................................. 26
Polski ..................................................................................................... 31
Product name: Oximeter
Arcle number: WH-OX01
Version: V1.1
Release date: April 2020
FINGER PULSE OXIMETER
USER’S MANUAL
EN - 1
English
OLED display modes
Features
OLED display
Two color OLED display, dierent display modes
Low-power consumpon, connuously four direcon adjustable
Low baery indicator
Automacally power o in 16 seconds when there is no signal
Compact, light in weight, and convenient to carry
EN - 2
English
1.1 InstruconsfortheSafeOperaonand
UseoftheFingerPulseOximeter
• Do not aempt to service the pulse oximeter.
Only qualied service personnel should aempt
any needed internal servicing.
• Do not use the oximeter in situaons where
alarms are required.
• Prolonged use or the paent’s condion may
require changing the sensor site periodically.
• Change sensor site and check skin integrity,
circulatory status and correct alignment at least
every 2 hours.
• Sp02 measurements may be adversely aected
in the presence of high ambient light. Shield the
sensor area (with a surgical towel, for example)
if necessary.
• The following reasons will cause interference:
• High-frequency electrosurgical devices
• Placement of a sensor on an extremity with
a blood pressure cu arterial catheter, or
intravascular line
• The paent has hypotension severe
vasoconstricon severe anemia or hypothermia
• The paent is in cardiac arrest or is in shock
• Fingernail polish or false ngernails may cause
inaccurate Sp02 readings
1.2 Warnings
WARNING
EXPLOSION HAZARD— Do not use the oximeter
in a ammable atmosphere where concentrations of
ammable anesthetics or other materials may occur.
WARNING
Do not throw batteries in re as this may cause them
to explode.
WARNING
Do not attempt to recharge normal dry-cell batteries,
they may leak. And may cause a re or even explode.
WARNING
Do not use the pulse oximeter in an MRI or CT
environment.
CAUTION
Keep the operating environment free of dust,
vibrations, corrosive, or ammable materials, and
extremes of temperature and humidity.
CAUTION
Do not operate the unit if it is damp or wet because
of condensation or spills. Avoid using the equipment
immediately after moving it from a cold environment
to a warm, humid location.
CAUTION Never use sharp or pointed objects to operate the
front-panel key.
CAUTION
The battery must be taken out from the battery
compartment if the device will not be used for a long
time.
CAUTION The device shall only be used if the battery cover
is closed.
CAUTION The battery must be proper disposed according to
local regulation after their use.
1.3 DenionsandSymbols
Whenplugging yourngerIntothe Oximeter, your
nailsurfacemustbeupward.
Instrucons:Please use the medical alcohol to clean
the rubber before each test and clean the tested
nger with alcohol before and aer the test.
• Install two AAA baeries into baery cassee
before covering its cover
• Open the Oximeter by pressing the back part
together, insert one nger with the ngernail
upwards in the Oximeter (ideally up to the end)
and close it by releasing the back part.
• Press buon on the front panel;
• Don’t tremble your nger when the Oximeter is
working. Please don’t move your body.
• Press the buon on the front panel, if you want
change display direcon;
• Read relevant date from display screen.
• The instrument has the sleep mode, no signal will
be received if it is in sleep mode.
• Please replace new baeries when OLED indicates
the baeries are in low power.
Section 1 Safety
Produktspecifikationer
Varumärke: | Well Health |
Kategori: | |
Modell: | WH-OX01 |
Behöver du hjälp?
Om du behöver hjälp med Well Health WH-OX01 ställ en fråga nedan och andra användare kommer att svara dig
Well Health Manualer
22 Augusti 2024
18 Augusti 2024
Manualer
- Xiaomi
- IKEA
- AEG Electrolux
- Delonghi
- Ag Neovo
- Acoustic Energy
- Akai Professional
- Amico
- Icy Box
- Asus
- TP Link
- United Office
- Energy Sistem
- House Of Marley
- Ultimate Speed
- Fresh N Rebel
- Seg
- Point Of View
- Citroën
- InFocus
- FriFri
- IDance
- Primo
- IHealth
- One For All
- DoorBird
- EBERLE
- Master
- IGPSport
- Smart
- Jawbone
- White And Brown
- OKBABY
- It Works
- HQ Power
- Mam
- Kundo XT
- Univers By FTE
- Europa Style
- Harley Davidson
- Bowers Wilkins
- JB Systems
- V7 Videoseven
- Bell Phones
- Gp Batteries
- Braun Phototechnik
- Offshore
- IRoad
- ICarsoft
- Inshape
- InterBar
- ResMed
- Dane Elec
- Bang En Olufsen
- Support Plus
- I.safe Mobile
- E-4Motion
- Riviera Bar
- Xbox
- Expo Borse
- Gigaset Elements
- Mtx Audio
- Ground Zero
- Identity Games
- Lisa Human Technik
- Fuji Electric
- Bodner Und Mann
- Smith Corona
- PCE Instruments
- Techno Line
- Gifwijzer Editie 2009
- Watchxl
- T Nb
- Vd Tech
- GT Bicycles
- DIT Is TV
- Quick Mill
- Oleo Mac
- ELNA Supermatic Bwj 1955
- GSM Voor Senioren
- Neomounts By Newstar
- What Do You Meme
- Silvercrossbaby
- Einhell - Blue Line
- ODBII System
- E-Domotica
- I12Cover
- ESYNiC
- Golden Interstar
- Studio
- Trendworx
- Bike Hanger
- Thera Pure Spa
- IFit
- Mc Crypt
- Black En Decker
- Hp Pavilion Dv7
- Fluke Networks
- G Data
- Wirlpool Type 288
- Home And Comfort
- Sagab By Elma
- Go On
- Home Electronic
- Onbekend
Nyaste Manualer
27 Oktober 2024
21 Oktober 2024
20 Oktober 2024
20 Oktober 2024
20 Oktober 2024
20 Oktober 2024
17 Oktober 2024
17 Oktober 2024
17 Oktober 2024
17 Oktober 2024