Worcester-Bosch Greenstar Comfort I RF - 2023 Bruksanvisning

Worcester-Bosch Termostat Greenstar Comfort I RF - 2023

Läs nedan 📖 manual på svenska för Worcester-Bosch Greenstar Comfort I RF - 2023 (20 sidor) i kategorin Termostat. Denna guide var användbar för 4 personer och betygsatt med 4.5 stjärnor i genomsnitt av 2 användare

Sida 1/20
UK/IE
Installation and operating instructions
Radio Frequency Twin Channel Programmer/Receiver and Room Thermostat
Greenstar Comfort I RF
6720810964-00.1Wo
select
advance
select
advance
menu
For EMS compatible Worcester Greenstar condensing boilers
6 720 810 964 (2017/02)
2
Contents
Comfort I – 6720810964 (2017/02)
Contents
1 Key to symbols and safety instructions . . . . . . . . . . . 3
1.1 Key to symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.2 General safety instructions . . . . . . . . . . . . . . . . . . 3
2 Comfort I RF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
2.1 Programmer/Receiver . . . . . . . . . . . . . . . . . . . . . . 4
2.2 RF Room thermostat . . . . . . . . . . . . . . . . . . . . . . . 5
3 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
3.1 Comfort I RF Installation . . . . . . . . . . . . . . . . . . . . 5
3.2 Programmer/Receiver mounting . . . . . . . . . . . . . 5
3.3 Room thermostat mounting . . . . . . . . . . . . . . . . . 7
3.4 Time and date set up . . . . . . . . . . . . . . . . . . . . . . . 8
4 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
4.1 Programmer/Receiver . . . . . . . . . . . . . . . . . . . . . . 9
5 Programmer/Receiver settings . . . . . . . . . . . . . . . . 10
5.1 User . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
5.1.1 Heating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
5.1.2 Hot water . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
5.1.3 Holiday function . . . . . . . . . . . . . . . . . . . . . . . . 11
5.1.4 Info . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
5.1.5 Setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
5.2 Installer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
5.2.1 Reset all . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
5.2.2 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
5.2.3 System info . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
5.2.4 Radio settings - Pair/Unpair . . . . . . . . . . . . . . . 13
5.3 Key lock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
6 Room thermostat . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
6.1 Normal operation . . . . . . . . . . . . . . . . . . . . . . . . . 13
6.2 Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
6.3 E 1 Room temperature sensor adjustment . . . . 15
6.4 F 1 Factory reset . . . . . . . . . . . . . . . . . . . . . . . . . 15
6.5 rF 1 Pair with other devices . . . . . . . . . . . . . . . . 15
6.6 S 1 Software version . . . . . . . . . . . . . . . . . . . . . . 15
6.7 S 2 RF signal strength . . . . . . . . . . . . . . . . . . . . . 15
7 Fault finding and resolution . . . . . . . . . . . . . . . . . . . . 16
7.1 Fault table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
7.2 Unit replacement . . . . . . . . . . . . . . . . . . . . . . . . . 17
7.2.1 Unpair . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
7.2.2 Pair . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
8 Servicing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
9 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
9.1 Room thermostat battery replacement . . . . . . . 18
10 ErP Class . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
11 Environment / disposal . . . . . . . . . . . . . . . . . . . . . . . 19
IMPORTANT
THE UNITS ARE PRE-COMMISSIONED,
NO RF PAIRING IS REQUIRED PRIOR TO USE
REPLACEMENT UNITS WILL REQUIRE PAIRING,
PLEASE REFER TO SECTION 7.2
3
Key to symbols and safety instructions
Comfort I– 6720810964 (2017/02)
1 Key to symbols and safety instructions
1.1 Key to symbols
Warnings
The following keywords are defined and can be used in this
document:
NOTICE indicates a situation that could result in damage to
property or equipment.
CAUTION indicates a situation that could result in minor to
medium injury.
WARNING indicates a situation that could result in severe
injury or death.
DANGER indicates a situation that will result in severe
injury or death.
Important information
Additional symbols
Abbreviations
Definitions (DST/BST)
Daylight Saving Time (DST) and British Summer Time (BST)
begins on the last Sunday in March at 1:00am GMT and clocks
are put forward by one hour.
British Summer Time (BST) ends on the last Sunday in October
at 2:00am BST and the clocks are put back by one hour.
1.2 General safety instructions
These installation instructions are intended for heating
engineers, and electricians.
Read any installation instructions (boiler, heating controls,
etc.) carefully before starting the installation.
Observe the safety instructions and warnings.
Observe national and regional regulations, technical rules
and guidelines.
Record all work carried out.
Appliance operation
This appliance can be used by children aged from 8 years and
above and persons with reduced physical, sensory or mental
capabilities or lack of experience and knowledge if they have
been given supervision or instruction concerning use of the
appliance in a safe way and understand the hazards involved.
Children shall not play with the appliance. Cleaning and user
maintenance shall not be made by children without
supervision. (BS EN 60335-1 2012)
Installation, commissioning and servicing
Installation, commissioning and servicing must only be carried
out by a competent engineer.
Only use original spares.
Electrical work
Electrical work must only be carried out by a qualified
electrician.
Before starting electrical work:
Isolate the mains electrical supply and secure against
unintentional re-connection.
–Check for zero voltage.
Also observe connection diagrams of other system
components.
Handover to the user
When handing over, instruct the user how to operate the
heating system and inform them about its operating
conditions.
Explain how to operate the heating system and draw the
user's attention to any safety-relevant action.
Explain that modifications and repairs must only be carried
out by an authorised contractor.
Advise the user to have the system serviced annually by a
competent engineer.
Leave this instruction manual with the user or at the
appliance.
Warnings in this document are identified by a
warning triangle printed against a grey
background.
Keywords at the start of a warning indicate the
type and seriousness of the ensuing risk if
measures to prevent the risk are not taken.
This symbol indicates important information
where there is no risk to people or property.
Symbol Explanation
Step in an action sequence
Cross-reference to another part of the document
List entry
List entry (second level)
CH = Central Heating
DHW = Domestic Hot Water
RF = Radio Frequency
DST = Daylight Savings Time
BST = British Summer Time
GMT = Greenwich mean time
RPB = Rotary Push Button

Produktspecifikationer

Varumärke: Worcester-Bosch
Kategori: Termostat
Modell: Greenstar Comfort I RF - 2023

Behöver du hjälp?

Om du behöver hjälp med Worcester-Bosch Greenstar Comfort I RF - 2023 ställ en fråga nedan och andra användare kommer att svara dig




Termostat Worcester-Bosch Manualer

Termostat Manualer

Nyaste Termostat Manualer