Chauvin Arnoux F604 Bruksanvisning

Läs nedan 📖 manual på svenska för Chauvin Arnoux F604 (29 sidor) i kategorin Multimeter. Denna guide var användbar för 3 personer och betygsatt med 4.5 stjärnor i genomsnitt av 2 användare

Sida 1/29
Clamp multimeter
EN - User’s manual
F604
3
0
0
0
A
2
0
0
0
A
1
0
0
0
V
C
A
T
I
V
1
5
0
0
V
C
A
T
I
I
I
COM +
1000 V CAT IV
1500 V CAT III
1700 V
1200 V
max
F604
AC/DC TRMS CLAMP METER
OFF
A
V
Adp
T °
°F
°C
P
AC DC
M MAX IN
kHz
kVA
%
0
°C°F
REL Ref
k
HOLD
2
WARNING, risk of DANGER ! The operator should refer to this user's manual whenever this danger symbol appears.
Application or withdrawal authorized on bare conductors carrying dangerous voltages. Type A current sensor as per
IEC/EN 61010-2-032 or BS EN 61010-2-032.
Battery.
Equipment protected throughout by double or reinforced insulation.
Earth.
The CE marking indicates compliance with the European Low Voltage Directive (2014/35/EU), Electromagnetic
Compatibility Directive (2014/30/EU), and Restriction of Hazardous Substances Directive (RoHS, 2011/65/EU and
2015/863/EU).
The UKCA marking certies that the product is compliant with the requirements that apply in the United Kingdom,
in particular as regards Low-Voltage Safety, Electromagnetic Compatibility, and the Restriction of Hazardous
Substances.
AC - Alternating current.
AC and DC - Alternating and direct current.
The rubbish bin with a line through it indicates that, in the European Union, the product must undergo selective
disposal in compliance with Directive WEEE 2012/19/EU. This equipment must not be treated as household waste.
Denitions of the measurement categories
Measurement category IV corresponds to measurements taken at the source of low-voltage installations.
Example: power feeders, meters and protection devices.
Measurement category III corresponds to measurements on building installations.
Example: distribution panel, circuit-breakers, machines or xed industrial devices.
Measurement category II corresponds to measurements taken on circuits directly connected to low-voltage installations.
Example: power supply to domestic electrical appliances and portable tools.
You have just acquired an and we thank you.F604 clamp multimeter
For best results from your device:
read this user manual attentively,
observe the precautions for its use.
3
CONTENTS
1. DELIVERY CONDITION ......................................................................................................................................................4
2. PRESENTATION ..................................................................................................................................................................5
2.1. The switch ...................................................................................................................................................................6
2.2. The keys of the keypad 7 ...............................................................................................................................................
2.3. The display unit 8 ...........................................................................................................................................................
2.4. The terminals ...............................................................................................................................................................9
3. THE KEYS ...........................................................................................................................................................................10
3.1. HOLD key 10 ................................................................................................................................................................
3.2. key (second function) .................................................................................................................................... 11
3.3. key ................................................................................................................................................................. 11
3.4. MAX/MIN key ................................................................................................................................................................. 11
3.5. Hz key 12 .................................................................................................................................................................
3.6. key 13 .................................................................................................................................................................
4. USE ...................................................................................................................................................................................... 14
4.1. Commissioning 14 ..........................................................................................................................................................
4.2. Starting up the clamp multimeter 14 ...............................................................................................................................
4.3. Switching the clamp multimeter 14 .................................................................................................................................
4.4. Conguration .............................................................................................................................................................14
4.5. Voltage measurement (V) 16 ..........................................................................................................................................
4.6. Continuity test .................................................................................................................................................16
4.7. Resistance measurement ......................................................................................................................................17
4.8. Diode test ........................................................................................................................................................17
4.9. Current measurement (A) 17 ..........................................................................................................................................
4.10. Starting current or over-current (True INRUSH) measurement 19 ...............................................................................
4.11. Frequency measurement (Hz) 19 .................................................................................................................................
4.12. Temperature measurement .....................................................................................................................................20
4.13. Adapter function measurement 21 ................................................................................................................................
5. CHARACTERISTICS .........................................................................................................................................................22
5.1. Reference conditions 22 .................................................................................................................................................
5.2. Characteristics under the reference conditions 22 .........................................................................................................
5.3. Environmental conditions 25 ..........................................................................................................................................
5.4. Characteristics of construction 25 ..................................................................................................................................
5.5. Power supply 26 .............................................................................................................................................................
5.6. Compliance with international standards 26 ...................................................................................................................
5.7. Variations in the domain of use 27 .................................................................................................................................
6. MAINTENANCE ..................................................................................................................................................................28
6.1. Cleaning 28 ....................................................................................................................................................................
6.2. Replacement of the batteries 28 .....................................................................................................................................
7. WARRANTY ........................................................................................................................................................................28

Produktspecifikationer

Varumärke: Chauvin Arnoux
Kategori: Multimeter
Modell: F604
Färg på produkten: Zilver
Vikt: 85 g
Bredd: 84 mm
Djup: 84 mm
Höjd: 34 mm
Internationell säkerhetskod (IP): IP20
Certifiering: CE, EMC
Material: Aluminium
Hållbarhetscertifikat: RoHS
Beslag/fottyp: GU10

Behöver du hjälp?

Om du behöver hjälp med Chauvin Arnoux F604 ställ en fråga nedan och andra användare kommer att svara dig




Multimeter Chauvin Arnoux Manualer

Multimeter Manualer

Nyaste Multimeter Manualer