h 4800-41
Cylinder Head Leakage Tester
(CO
2
leak detector)
Dear Customer,
You have made a good choice. With a HAZET Cylinder Head Leakage
Tester, you have a quality tool in your hands. Directions for use are
given below.
First, some general information
Testing can be carried out at any time, whether the engine is hot or
cold. As a rule, no preparation of the vehicle for a routine test is
required. Nevertheless, if the engine has cooled over a prolonged
period of time, fresh air will have been drawn into the cooling system,
diluting any combustion gas which may be present in the air cushion.
The Cylinder Head Leakage Tester permits the early,HAZET 4800-41
rapid and reliable detection of leaks between the cooling system
and the combustion chambers of all coolant cooled petrol, diesel
and LPG engines.
Any combustion gas which leaks into the cooling system through a
defect in the cylinder head gasket, sealing faces, hairline cracks,
cylinder liners or even porous parts of the cylinder head, collects in the
air cushion in the radiator or header tank.
The enables the air cushion to be tested for combustion gas (increased COHAZET 4800-41
2
content). Leaks can
also be detected subsequently.
The blue detecting fluid indicates whether the in-drawn air contains an increased level of carbon dioxide by changing
colour from blue green yellow, first to , then to . An increased CO
2
content in the cooling system indicates a leak
between the combustion chamber and the cooling system, i.e. the presence of combustion gas in the cooling
system.
The proven prevents erroneous diagnoses, as follows. In the first chamber, alkaline‘HAZET dual chamber system’
particles are absorbed while, in the second, a leak resulting in an increased content of CO
2
gas (combustion gas)
will give rise to a change in the colour of the fluid from blue to yellow.
TEST PROCEDURE:
Half-fill both chambers of the tester with reactive fluid.
Remove the radiator cap and install a special adapter or universal adapter.HAZET 4800-4 HAZET 4800-3
Connect the tester HAZET 4800-41.
Run the engine.
After a short time, bubbles will form in both chambers.
In the first chamber, impurities (e.g. coolant, etc.) may undergo a change of colour. The actual result, however, can
only be determined from the second chamber in which the through-flowing gas alone is able to change colour.
TEST RESULTS:
쎲 쑺Fluid stays blue No leak
쎲 쑺Fluid changes from blue to yellow (petrol engines) Leak in cylinder head gasket
or from blue to green (diesel engines) or cylinder head
The fluid can be restored to its original colour (blue) simply by blowing through with compressed air. It can continue to
be used until it no longer reverts to its original colour.
Suggested uses:
As a routine test at every service and before replenishing antifreeze. To check repairs, e.g. after pronounced
overheating of the engine as a result of a leak or defect in the water pump, V-belt, radiator hose, etc. In combination
with a pressure test for externally escaping leaks (max. possible test pressure, 1 bar); this also reveals leaks which
would otherwise only occur at a very high combustion pressure or when the vehicle is being driven.
Leak detector maintenance:
The non-return valve in the connector may become clogged with coolant and contamination. For cleaning purposes,
wash the chambers out with white spirit and blow compressed air through the connector from below.
*) CAUTION - RISK OF SCALDING: If the engine is hot, remove the cap slowly and allow the pressure to dissipate.
We reserve the right to alter technical specifications without notice.
h
4800-41engl. 08.2001
HAZET-WERK
HIGHEST TECHNOLOGY IN TOOL MANUFACTURE SINCE 1868

Produktspecifikationer

Varumärke: Hazet
Kategori: Mätutrustning
Modell: 4800-41

Behöver du hjälp?

Om du behöver hjälp med Hazet 4800-41 ställ en fråga nedan och andra användare kommer att svara dig




Mätutrustning Hazet Manualer

Hazet

Hazet 1992N-1 Bruksanvisning

26 September 2024
Hazet

Hazet 4800-41 Bruksanvisning

25 September 2024
Hazet

Hazet 4956-1 Bruksanvisning

21 September 2024

Mätutrustning Manualer

Nyaste Mätutrustning Manualer