Master MH-400T-KFA Bruksanvisning

Master Värmare MH-400T-KFA

Läs nedan 📖 manual på svenska för Master MH-400T-KFA (15 sidor) i kategorin Värmare. Denna guide var användbar för 6 personer och betygsatt med 4.5 stjärnor i genomsnitt av 2 användare

Sida 1/15
Model Number
MH-400T-KFA
CONSUMER: READ AND SAVE THESE INSTRUCTIONS
GENERAL HAZARD WARNING: Be sure to comply with the
instructions and warnings provided with this heater, or death,
serious bodily injury and property loss, damage from the hazards
of fire, explosion, burn,asphyxiation, and carbon monoxide poisoning can result.
Only persons who can follow and understand these instructions should use or service this
heater. If you need heater information such as an instruction manual, labels, etcetera,
contact the manufacturer.
DANGER
Sauk Rapids, MN 56379 USA • Toll Free (800) 641-6996
Fax: 320-251-2922 • Web: www.masterindustrialproducts.com • Email: info@pinnacleclimate.com
© 2020 Pinnacle Climate Technologies, Inc. MAKE-409
Users Manual &
Operating Instructions
KEROSENE FORCED AIR
HEATER
IMPORTANT: Read and understand all of the directions in this manual before assembling,
starting, or servicing the heater. Improper use of this heater can cause serious injury. Keep
this manual for future reference. The requirements of local authorities having jurisdiction
shall be followed.
Not for use in residential living areas or in non-adequately
ventilated enclosed spaces. Suitable for outdoor use. Indoor use
permitted for: The temporary heating of adequately ventilated
buildings or structures under construction, alteration or repair.
DANGER
NEVER LEAVE HEATER UNATTENDED WHILE BURNING
OR WHILE CONNECTED TO A POWER SOURCE
© 2020, Pinnacle Climate Technologies, Inc. Kerosene Forced Air Heater User’s Manual
2
This is a kerosene direct-red, forced air heater. Kerosene forced
air heaters are primarily intended for use for temporary heating
of buildings under construction, alteration or repair. Direct-red
means that all of the combustion products of the heater enter the
heated space. This appliance is rated at 98% combustion efciency,
but does produce small amounts of carbon monoxide. Carbon
monoxide is toxic.
Humans can tolerate small amounts of carbon monoxide, and
precautions should be taken to provide proper ventilation. Failure
to provide proper ventilation according to this manual can result
in death. Early signs of carbon monoxide poisoning resemble the
u. Symptoms of improper ventilation are: Symptoms of improper
ventilation / carbon monoxide poisoning are:
Headache • Dizziness • Nausea Dry Mouth Sore Throat •
Burning of Nose and Eyes
For optimal performance of this heater, it is strongly suggested
that K-1 kerosene be used. K-1 kerosene has been refined to
virtually eliminate contaminants, such as sulfur, which can cause
a rotten egg odor during the operation of the heater. Diesel may
also be used if K-1 kerosene is not available. Be advised that
diesel does not burn as clean as K-1 kerosene, and care should
be taken to provide more fresh air ventilation to accommodate any
added contaminants that may be added to the heated space. Use
of diesel may result in more periodic maintenance.
- CSA certified for use with K-1 kerosene, no. 1 & no. 2 diesel,
JP8/Jet A Fuel
Risk of indoor air pollution!
- Use this heater only in well ventilated areas! Provide, at heater
level, at least a three square foot (2,800 sq. cm) opening of
outside air for every 100,000 BTU/hr of heater rating.
- People with breathing problems should consult a physician
before using the heater.
- Carbon Monoxide Poisoning: Early signs of carbon monoxide
poisoning resemble flu-like symptoms such as headaches,
dizziness, and/or nausea. If you have these symptoms, your
heater may not be working properly.
- Get fresh air at once! Have the heater serviced. Some people
are more affected by carbon monoxide than others. These include
pregnant women, those with heart or lung problems, anemia, or
those under the influence of alcohol, or at high altitudes.
Risk of burns / fire / explosion!
- NEVER use fuels such as gasoline, benzene, paint thinners,
crankcase drainings, or other oil compounds in this heater (RISK
OF FIRE OR EXPLOSION).
MASSACHUSETTS RESIDENTS: Massachusetts
state law prohibits the use of this heater in any building which
is used in whole or in part for human habitation. Use of this
heating device in Massachusetts requires local fire department
permit (M.G.L.C. 148, Section 10A).
NEW YORK CITY RESIDENTS: The New York City
Fire Code prohibits the storage, handling and use of kerosene
fueled heaters for space heating. Any person violating that
provision may be punished by a fine up to $10,000 and a term
of imprisonment of up to 6 months.
WARNING: This product can expose you to chemicals,
including lead, which is known to the State of California to
cause birth defects or other reproductive harm. For more
information visit www.p65warnings.ca.gov
Table of Contents
Safety Information ......................................................................2-3
Features 3 ........................................................................................
Specifications 4 ................................................................................
Unpacking...................................................................................... 5
Assembly 5-6 ....................................................................................
Operation 6-8 ....................................................................................
Maintenance 9-11 .............................................................................
Wiring Diagram ............................................................................ 11
Exploded View ............................................................................. 12
Parts List ..................................................................................... 13
Troubleshooting Guide ................................................................ 14
Warranty 15 ......................................................................................
FIRE, BURN, INHALATION AND
EXPLOSION HAZARD. Keep com-
bustibles such as building materials,
paper or cardboard a safe distance away from the heater as
recommended by these instructions. Never use the heater in
spaces which contain products such as gasoline, solvents, paint
thinners, dust particles, volatile or airborne combustibles or any
unknown chemicals. This is an unvented portable heater. It
uses air (Oxygen) from the area in which it is used. Adequate
combustion and ventilation air must be provided. Refer to
“Ventilation” on page 7.
WARNING
DO NOT OPERATE THIS HEATER
UNTIL YOU HAVE READ AND
THOROUGHLY UNDERSTAND
THESE SAFETY AND OPERATING INSTRUCTIONS. Failure
to comply with the precautions and instructions provided with
this heater can result in death, serious bodily injury, property
loss or damage from the hazards of fire, soot production, explo-
sions, burns, asphyxiation or carbon monoxide poisoning. Only
persons who can read and understand these instructions should
use or service this heater.
WARNING
Safety Information
Indicates an imminently hazardous
situation which, if not avoided, WILL
result in death or serious injury.
Indicates a potentially hazardous situa-
tion which, if not avoided, COULD result
in death or serious injury.
Indicates a potentially hazardous
situation which, if not avoided, MAY
result in minor or moderate injury.
WARNING
DANGER
CAUTION
CARBON MONOXIDE POISONING MAY
LEAD TO DEATH!
DANGER
WARNING
WARNING
NEVER LEAVE HEATER UNATTENDED WHILE BURNING
OR WHILE CONNECTED TO A POWER SOURCE
© 2020, Pinnacle Climate Technologies, Inc. Kerosene Forced Air Heater User’s Manual
3
- NEVER refill the heater’s fuel tank while heater is operating or
still hot. This heater is EXTREMELY HOT while in operation.
- Keep all combustible materials away from this heater.
- NEVER block air inlet (rear) or air outlet (front) of heater.
- NEVER use duct work in front or at rear of heater.
- NEVER move or handle heater while still hot.
- NEVER transport heater with fuel in its tank.
- If equipped with a thermostat, the heater may start at any time.
- ALWAYS locate heater on a stable and level surface.
- ALWAYS keep children and animals away from heater.
- Bulk fuel storage should be a minimum of 25 ft. from heaters,
torches, portable generators, or other sources of ignition. All
fuel storage should be in accordance with federal, state, or local
authorities having jurisdiction.
- Never use this heater in living or sleeping areas.
- NEVER use this heater where flammable vapors may be present.
Risk of electric shock!
- Use only the electrical power (voltage and frequency) specified
on the model plate of the heater. Use only a three- prong,
grounded outlet and extension cord.
- ALWAYS install the heater so that it is not directly exposed to
water spray, rain, dripping water, or wind.
- ALWAYS unplug the heater when not in use.
Minimum Clearance From Combustibles
MH-400T-KFA
Top 4 ft. (125 cm)
Sides 4 ft. (125 cm)
Front 8 ft. (250 cm)
Safety Information (Continued)
WARNING
Features
Front Handle
Hot Air outlet
Safety Guard
Lower Shell
Upper Shell
Fuel Cap
Fuel Gauge
Extension
Cord Wrap
Rear Handle
Fan Guard
Power Cord
Side Cover
Control Panel
Fuel Tank
Drain Bolt
(Bottom-Front
of Fuel Tank)
Figure 1. Features of Model MH-400T-KFA

Produktspecifikationer

Varumärke: Master
Kategori: Värmare
Modell: MH-400T-KFA

Behöver du hjälp?

Om du behöver hjälp med Master MH-400T-KFA ställ en fråga nedan och andra användare kommer att svara dig




Värmare Master Manualer

Värmare Manualer

Nyaste Värmare Manualer