MODEL NUMBERS:
MH-80TBOA-KFA
CONSUMER: READ AND SAVE THESE IMPORTANT INSTRUCTIONS
GENERAL HAZARD WARNING: READ AND UNDERSTAND
ALL OF THE INSTRUCTIONS IN THIS MANUAL BEFORE
ASSEMBLING, STARTING, OR SERVICING THE HEATER. Be sure
to comply with the instructions and warnings provided with this heater. Failure to comply can
result in fire or explosion that can cause property loss, bodily injury, or loss of life. Persons
who are impaired or under the influence of alcohol or drugs should not operate heater.
Only persons who can follow and understand these instructions should operate or service
this heater. If you need heater info; such as an operating manual, labels, etcetera, contact
Pinnacle Climate Technologies at 800-641-6996.
DANGER
NOT FOR USE IN RESIDENTIAL LIVING AREAS OR IN ENCLOSED
SPACES WITHOUT ADEQUATE VENTILATION. THIS HEATER
IS NOT FOR USE WHERE EXPOSED TO THE WEATHER, AND
INDOOR USE ONLY IN WELLVENTILATED AREAS. INDOOR USE PERMITTED ONLY FOR:
THE TEMPORARY HEATING OF ADEQUATELY VENTILATED BUILDINGS OR STRUCTURES
UNDER CONSTRUCTION, ALTERATION OR REPAIR. This is an unvented portable heater
that uses air (Oxygen) from within the area in which it is used. Failure to provide adequate
combustion and ventilation air will result in asphyxiation, carbon monoxide poisoning, bodily
injury or death. Refer to “Ventilation” on Page 5.
FACTORY ID: 500
DANGER
Sauk Rapids, MN 56379 USA • Toll Free (800) 641-6996
Fax: 320-251-2922 • Web: www.masterindustrialproducts.com • Email: info@pinnacleclimate.com
© 2023 Pinnacle Climate Technologies, Inc. MAKD-435Master is a registered trademark of Pinnacle Climate Technologies, Inc.
BATTERY OPERATED
KEROSENE FORCED AIR HEATER
User’s Manual & Operating Instructions
Locating Your Serial Number:
Your serial number can be found on a white label on the right side cover of your heater. For Example:
150812779. Have your Serial Number ready before calling customer service at 800-641-6996.
Heater is intended for use without ducts. DO
NOT connect to ducts. DO NOT tamper with
the unit. Have a competent serviceman make
any adjustment or repair. DO NOToperate the unit in close proximity to
combustible surfaces or materials. Allow the unit to cool before shut down.
Remove battery if the heater is not in use.
WARNING
2
NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR
WHILE CONNECTED TO A POWER SOURCE
© 2023 Pinnacle Climate Technologies, Inc. Kerosene Forced Air Heater User’s Manual
MASSACHUSETTS RESIDENTS: Massachusetts state law prohibits the use of this heater in
any building which is used in whole or in part for human habitation. Use of this heating device
in Massachusetts requires local fire department permit (M.G.L.C. 148, Section 10A).
NEW YORK CITY RESIDENTS: The New York City Fire Code prohibits the storage, handling
and use of kerosene fueled heaters for space heating. Any person violating that provision may
be punished by a fine up to $10,000 and a term of imprisonment of up to 6 months.
Look for this icon throughout the manual for helpful tips on how to assemble, use and
clean your KFA Heater.
THE INSTALLATION OF THE EQUIPMENT SHALL BE IN ACCORDANCE WITH THE
REGULATION OF AUTHORITIES HAVING JURISDICTION AND CSA STANDARD B139.
WARNING: This product can expose you to chemicals, including leadand lead
compounds, whichareknown to the State of California to cause cancer and birth defects
or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
DO NOT START THE HEATER WHEN EXCESS OIL HAS ACCUMULATED.
DO NOT START THE HEATER WHEN THE CHAMBER IS HOT.
WARNING
WARNING
FIRE, BURN, INHALATION AND EXPLOSION HAZARD. Keep com-
bustibles such as; building materials, paper or cardboard a safe dis-
tance away from the heater as recommended by these instructions.
Never use the heater in spaces which contain products such as; gasoline, solvents, paint
thinners, dust particles, volatile or airborne combustibles or any unknown chemicals. This is
an unvented portable heater. It uses air (Oxygen) from the area in which it is used. Adequate
combustion and ventilation air must be provided. Refer to “Ventilation” on page 5. Bulk fuel
storage should be a minimum of 25 feet (7.6 m) from heater.
WARNING
DO NOT OPERATE THIS HEATER UNTIL YOU HAVE READ AND
THOROUGHLY UNDERSTAND THESE SAFETY AND OPERATING
INSTRUCTIONS.
Failure to comply with the precautions and instructions provided with
this heater can result in death, serious bodily injury, property loss or damage from the hazards of
fire, soot production, explosions, burns, asphyxiation or carbon monoxide poisoning. Only per-
sons who can read and understand these instructions should use or service this heater.
WARNING
SAFETY INFORMATION
Safety Information 2-3 .....................................................
What’s in the Box 4 ...........................................................
Specifications 4 .................................................................
Features 4 ...........................................................................
Assembly Instructions 4 ..................................................
Operation 5-6 ....................................................................
Battery Operation Instructions 7 ...................................
Maintenance 8-9 ...............................................................
Wiring Diagrams 10 ..........................................................
Troubleshooting Guide 11 ...............................................
Exploded View
............................................................
12
Parts List 13 ........................................................................
Limited Warranty 14 ..........................................................
TABLE OF CONTENTS
3
NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR
WHILE CONNECTED TO A POWER SOURCE
© 2023 Pinnacle Climate Technologies, Inc. Kerosene Forced Air Heater User’s Manual
SAFETY INFORMATION CONT.
ALWAYS use only the electrical power (voltage and
frequency) specied on the model plate of the heater.
ALWAYS use only three-prong, grounded outlet and
extension cord.
ALWAYS use only 14 AWG or better extension cord.
ALWAYS unplug the heater when not in use.
ALWAYS install the heater so that it is not directly
exposed to water spray, rain, dripping water, or wind.
NEVER use fuels such as gasoline, benzine, paint
thinners or other oil compounds in this heater.
NEVER refill the heaters fuel tank while the heater
is operating or still hot. This heater is EXTREMELY
HOT while in operation.
NEVER block air inlet (rear) or air outlet (front).
NEVER use duct work in front or rear of heater.
NEVER move or handle heater while still hot.
NEVER transport heater with fuel in tank.
NEVER use with an external fuel tank.
Keep all combustible materials away from this heater.
Minimum Clearance From Combustibles
MH-80TBOA-KFA
Top 4 ft. (122 cm)
Sides 4 ft. (122 cm)
Front 8 ft. (244 cm)
ALWAYS locate heater on a stable and level surface.
If your heater is equipped with a thermostat, once it
is plugged in, it can start at anytime in accordance
with the thermostat setting.
Do not add fuel when the heater is running.
Heater should be re-started within 24 hours of
operation.
RISK OF BURNS,
FIRE AND
EXPLOSION!
RISK OF ELECTRIC
SHOCK!
WARNING
WARNING
CAUTION! HOT
WHILE IN OP-
ERATION. DO
NOT TOUCH. KEEP CHILDREN, ANIMALS,
CLOTHING AND COMBUSTIBLES AWAY
FROM HEATER.
WARNING
The products described in this manual are
kerosene direct-fired, forced air heaters. Kerosene
forced air heaters are primarily intended for use for
temporary heating of buildings under construction,
alteration or repair. Direct-fired means that all
of the combustion products of the heater enter
the heated space. This appliance is rated at 98%
combustion eciency, but does produce small
amounts of carbon monoxide.
Carbon monoxide is toxic. Humans can tolerate
only small amounts of carbon monoxide and so
precautions should be taken to provide proper
ventilation. Failure to provide proper ventilation
in accordance with the instructions in this
manual can result in death.People with breathing
problems should consult a physician before
using this heater. Early signs of carbon monoxide
poisoning resemble theu. Symptoms of improper
ventilation/carbon monoxide poisoning are:
Headache Dizziness Nausea Dry Mouth Sore
Throat Burning of Nose and Eyes
If you experience any of these symptoms:
GET FRESH AIR AT ONCE! Have your heater
serviced and check for proper ventilation. Some
people are more aected by carbon monoxide
than others. These include: pregnant women, those
with heart or lung problems, anemia or those under
the influence of alcohol or at high altitudes.
NOT FOR USE WHERE EXPOSED TO THE
WEATHER, INDOOR USE PERMITTED ONLY FOR:
The temporary heating of adequately ventilated
buildings or structures under construction,
alteration or repair. Provide at least a three
square foot (2,800 sq cm) opening of outside air
for every 100,000 Btu/Hr (29 kW) heater rating.
Refer to “Ventilation” on page 6 for further
instructions.
RISK OF INDOOR
AIR POLLUTION!
WARNING
CARBON
MONOXIDE
POISONING MAY
LEAD TO DEATH!
DANGER