PowerWalker VFD 600 APFC Bruksanvisning
PowerWalker
UPS
VFD 600 APFC
Läs nedan 📖 manual på svenska för PowerWalker VFD 600 APFC (72 sidor) i kategorin UPS. Denna guide var användbar för 3 personer och betygsatt med 4.5 stjärnor i genomsnitt av 2 användare
Sida 1/72
EN
EN
Standby (Oine) UPS
PowerWalker VFD 600 APFC
PowerWalker VFD 800 APFC
PowerWalker VFD 600 APFC/FR
PowerWalker VFD 800 APFC/FR
Manual
EN/DE/FR/PL/RU/PT
Uninterruptible Power Supply System
IMPORTANT SAFETY INSTRUCTIONS SAVE THESE
INSTRUCTIONS
CAUTION!!
Please read the following information carefully and save this manual for
further reference. Disregard of these safety notes may endanger life or
health, as well as the function of the equipment and the safety of your data.
Risk of Electric Shock Heatsinks are live. Disconnect unit before
servicing.
Risk of Electric Shock. This unit receives power from more than one
source. Disconnection of AC sources and the DC source is required to
de-e nergize this unit before servicing.
Risk of Electric Shock. Hazardous live parts inside this unit are
energized from the battery supply even when the input AC power is
disconnected.
Risk of Electric Shock. Do not remove cover. No user serviceable parts
inside. Refer servicing to qualified service personnel.
To reduce the risk of fire, replace only with same type of fuse. Refer
servicing to qualified service personnel only.
The sum of the leakage current of the UPS and the connected
equipment should not exceed 3.5mA.
Do not dispose of batteries in a fire as they may explode.
Do not open or mutilate the battery or batteries. Released electrolytes
are harmful to the skin and eyes. It may be toxic.
A battery can present a risk of electric shock and of having a high short
circuit current. The following precaution should be observed when
working on batteries:
1) Remove watches, rings or other metal objects from the handles.
2) Use tools with insulated handles.
3) Wear rubber gloves and boots.
4) Do not lay tools or metal parts on top of batteries.
5) Disconnect charging source prior to connecting or disconnecting
EN
EN
batteries terminal.
To replace the batteries by qualified service personnel. Use the same
number and type of sealed lead acid batteries.-
This pluggable type A equipment with battery already installed by the
supplier is operator installable and may be operated by laymen.
The mains socket outlet that supplies the UPS shall be installed near
the UPS and shall be easily accessible.
- Sealed, lead acid, 6 cells battery.
φ on the rating label stands for phase symbol.
The maximum ambient temperature rating is 40°C.
WARNING!!
Refer servicing to qualified service personnel only.
To reduce the risk of fire or electric shock, install in a temperature and
humidity controlled indoor area free of conductive contaminants.
Risk of Electric Shock. Battery circuit is not isolated from AC input,
hazardous voltage may exist between battery terminals and ground.
Test before touching.
System Description
Produktspecifikationer
Varumärke: | PowerWalker |
Kategori: | UPS |
Modell: | VFD 600 APFC |
Behöver du hjälp?
Om du behöver hjälp med PowerWalker VFD 600 APFC ställ en fråga nedan och andra användare kommer att svara dig
UPS PowerWalker Manualer
22 September 2024
22 September 2024
20 September 2024
20 September 2024
20 September 2024
20 September 2024
20 September 2024
20 September 2024
20 September 2024
UPS Manualer
- UPS AEG
- UPS IKEA
- UPS HP
- UPS Siemens
- UPS Apc
- UPS LC-Power
- UPS Tripp Lite
- UPS Energenie
- UPS Voltcraft
- UPS Emerson
- UPS Adj
- UPS Digitus
- UPS LevelOne
- UPS Eaton
- UPS Jung
- UPS CyberPower
- UPS Block
- UPS Avocent
- UPS Minuteman
- UPS Maruson
- UPS V7
- UPS Salicru
- UPS Equip
- UPS Approx
- UPS SurgeX
- UPS Murr Elektronik
- UPS Altronix
- UPS Ditek
- UPS Bxterra
- UPS Middle Atlantic
- UPS FSP
- UPS Atlantis Land
- UPS FSP/Fortron
- UPS Online USV
Nyaste UPS Manualer
24 Oktober 2024
22 Oktober 2024
22 Oktober 2024
22 Oktober 2024
20 Oktober 2024
18 Oktober 2024
18 Oktober 2024
13 Oktober 2024
13 Oktober 2024
13 Oktober 2024