ENGLISH
PowerWalker VI 600 1500 CSW-
Quick Guide
I. Overview:
1. LCD display
2. Up/down buon
3. Mute buon
4. ON / OFF buon
5. USB charging port
(5V / 2.1A shared
between 2 ports)
6. USB Communicaon
port with HID support
7. Surge protected -
outlets (no baery
backup)
8. Baery backup with
surge protected
outlets
9. RJ-45 surge protecon
(i.e. for Internet)
10. AC input
11. Venlaon and fan.
12. Circuit breaker (for
French and Schuko)
Surge protected outlets offer EMI ltering, line condioning and surge protecon, -
but they are not supported with backup power from battery in case of AC failure.
II. Operaon
Buon
Funcon
ON/OFF
buon
Press and hold the On/O Buon for 2 seconds and then release to
change state between Standby (output is o) and Line (output is on).
Mute buon
Press and hold the Mute buon for 1 second and then release to
mute or unmute the alarm.
Up/down
buon
Click to switch displayed informaon.
ENGLISH
III. Display
State
Meaning
LED
Alarm
Line /
Standby /
Baery
mode
Input voltage, input frequency, baery voltage, baery
Power, Backup me, output voltage, output frequency,
load Power and load percentage.
k: kilo, W: wa, V: voltage, A: ampere, %: percent, degC:
centigrade degree, Hz: frequency, min: minute
Line
Mode
The UPS is connected to AC input.
AVR
Mode
When the icon is ashing, the UPS is regulang the
voltage (reducing or increasing the voltage).
Baery
Mode
The UPS is running on battery
every
10 s
All Modes
The UPS alarm is disabled.
All Modes
Baery level in ranges 0 24%, 25 49%, 50 74%, and 75- - - -
100%.
Baery
Mode
Low Battery
every
0.5s
every
1s
All Modes
Load level in ranges 0-24%, 25-49%, 50-74% and 75-100%.
All Modes
Indicates overload.
every
0.5s
every
0.5s
All Modes
Baery replacement needed or the baery is not
connected
Conn
uous
every
2s
Fault
Fault code (here: E14). Check troubleshoong for details.
Connu
ous
Warning
Baery voltage is too high (i.e. wrong baery inserted)
every
1.5s
ENGLISH
IV. Baery Replacement
1. Turn o the connected equipment and unplug it
from the UPS
2. Turn o the UPS and unplug the input cable.
3. Remove two screws located on the boom of the
UPS and slide the baery cover downward, then
outward.
4. Disconnect the baery connector.
5. Slide out the exisng baery pack from the UPS
by grasping the baery pull tap.
Cauon - Do not short the posive wire and negave wire
of baery.
Cauon - DO NOT pull the baery pack out by pulling on
the baery wires.
6. Slide the new baery pack into the UPS.
7. Verify proper polarity. Re connect the baery -
connectors together.
8. Reinstall the battery cover onto the UPS. Now,
the UPS is ready for normal operaon
9. Properly dispose of the old baeries at an
appropriate recycling facility or return them to
the supplier in the packing material for the new
baeries.
Please read all of the WARNINGS and CAUTIONS in the General Manual before
replacing the baeries.
V. Troubleshoong
Fault
Event
E12
Baery mode output high (internal fault)
E14
Output short (check the loads)
E15
Output over current (too much load)
E20
Fan lock fault
E21
Over Charge Voltage (i.e. wrong baery used)
E28
Low baery voltage
E43
Overload fault
Please check hps://troubleshoot.powerwalker.com for more details.