Owner’s Manual
1111 W. 35th Street, Chicago, IL 60609 USA • www.tripplite.com/support
Copyright © 2014 Tripp Lite. All rights reserved. SmartPro
® is a registered trademark of Tripp Lite.
Español 22
Français 43
SmartPro® 2U Rackmount
Intelligent, Line-Interactive UPS Systems
120V Sine Wave Output • 2200VA—3000VA Capacities
SMART2200RM2U
(Series Number: AGSM8207)
SMART2200RMXL2U
(Series Number: AGSM8208)
SMART2200RMXL2UP
(Series Number: AGSM7012)
SMART3000RM2U
(Series Number: AGSM8209)
SMART3000RMXL2U
(Series Number: AGSM7010)
SMART3000RM2UP
(Series Number: AGSM7499)
Not suitable for mobile applications.
SMART2600RM2U
(Series Number: AGSM7012)
14-03-028-93-3088.indb 1 3/20/2014 4:08:27 PM
2
Important Safety Instructions
SAVE THESE INSTRUCTIONS
This manual contains important instructions that should be followed during the installation,
operation and storage of this product. Failure to heed these warnings may affect the warranty.
UPS Location Warnings
• UsecautionwhenliftingtheUPS.BecauseoftheconsiderableweightofallrackmountUPS
systems, at least two people should assist in lifting and installing them.
• InstalltheUPSindoors,awayfromexcessmoistureorheat,dustordirectsunlight.
• Forbestperformance,theambienttemperatureneartheUPSshouldbebetween0°Cand40°C
(between32°Fand104°F).
• LeaveadequatespacearoundallsidesoftheUPSforproperventilation.Donotobstructitsvents
or fan openings.
• WhenmountingtheUPSsysteminatowerorientation,makesuretheLCDScreenpanelisatthe
topoftheUPS,notatthebottom.
• Donotmountunitwithitsfrontorrearpanelfacingdown(atanyangle).Mountinginthismanner
will seriously inhibit the unit’s internal cooling, eventually causing product damage not covered
under warranty.
UPS Connection Warnings
• TheUPScontainsitsownenergysource(battery).Theoutputterminalsmaybeliveevenwhen
theUPSisnotconnectedtoanACsupply.
• ConnecttheUPStoaproperlygroundedACpoweroutlet.DonotmodifytheUPS’spluginaway
thatwouldeliminatetheUPS’sconnectiontoground.Donotuseadaptersthateliminatethe
UPS’sconnectiontoground.
• DonotplugtheUPSintoitself;thiswilldamagetheUPSandvoidyourwarranty.
• IfyouareconnectingtheUPStoamotor-poweredACgenerator,thegeneratormustprovide
filtered,frequency-regulatedcomputer-gradeoutput.ConnectingtheUPStoageneratorwillvoid
itsUltimateLifetimeInsurance.
Equipment Connection Warnings
• Useofthisequipmentinlifesupportapplicationswherefailureofthisequipmentcanreasonably
beexpectedtocausethefailureofthelifesupportequipmentortosignificantlyaffectitssafety
oreffectivenessisnotrecommended.Donotusethisequipmentinthepresenceofaflammable
anestheticmixturewithair,oxygenornitrousoxide.
• DonotconnectsurgesuppressorsorextensioncordstotheoutputoftheUPS.Thismight
damagetheUPSandmayaffectthesurgesuppressorandUPSwarranties.
14-03-028-93-3088.indb 2 3/20/2014 4:08:27 PM
3
Battery Warnings
• Batteriescanpresentariskofelectricalshockandburnfromhighshort-circuitcurrent.Observe
properprecautions.Donotdisposeofthebatteriesinafire.DonotopentheUPSorbatteries.
Donotshortorbridgethebatteryterminalswithanyobject.UnplugandturnofftheUPSbefore
performingbatteryreplacement.Usetoolswithinsulatedhandles.Therearenouser-serviceable
partsinsidetheUPS.Batteryreplacementshouldbeperformedonlybyauthorizedservice
personnelusingthesamenumberandtypeofbatteries(SealedLead-Acid).Thebatteries
arerecyclable.Refertoyourlocalcodesfordisposalrequirementsorvisitwww.tripplite.com/
UPSbatteryrecyclingforrecyclinginformation.TrippLiteoffersacompletelineofUPSSystem
ReplacementBatteryCartridges(R.B.C.).VisitTrippLiteontheWebatwww.tripplite.com/support/
battery/index.cfmtolocatethespecificreplacementbatteryforyourUPS.TheRBCTypecan
alsobefoundonthelabelaffixedtotheBatteryRetentionPlate.
• Duringhot-swapbatteryreplacement,theUPSwillnotprovidebackuppowerintheeventofa
blackout or other power interruptions.
• DonotoperatetheUPSwithoutbatteries.
External Battery Connection Warnings
• Whenaddingexternalbatterypackstoselectmodelswithexternalbatterypackconnectors,
connectonlyTrippLite-recommendedbatterypacksofthecorrectvoltageandtype.Donot
connectordisconnectbatterypackswhentheUPSisoperatingonbatterypower.
Visitwww.tripplite.com/support/battery/index.cfmtolocatethesupportedbatterytype(s)for
yourUPS.
Important Safety Instructions