RCI MEM4400
Installation
The patented MEM4400SK mechanical electro magnet locking device is designed for securing automatic sliding
door mechanisms. The MEM device has a holding force of 4000N. Simple installation with little or no fabrica-
tion or machining required to provide high security to automatic sliding doors of all types of construction.
Wiring and power input requirements
PCB connection:
Power input +12VDC/24VDC, 1A max
DSS sensor input Normally open
MEM lock power output Connect to MEM Power Input. Connect L+ to (+), Connect L- to RED BLACK (-)
Exit input Normally open
Auto door control output Normally open. Relay output. Connect to auto door control panel input
Alarm relay timer input Normally open. Short to active the C/NC/NO alarm relay output. Connect EW sensor
output and .BROWN GRAY
Alarm relay output C/NC/NO Relay output. 0-30 seconds delay timer
MEM lock wiring (to PCB):
MEM power input 12VDC, (+); (-)RED BLACK
EW sensor output White (NC), (C), (NO), 30VDC, 0.2A maxBROWN GRAY